Municipal Waste Water
- All Products
- 2-way Angle Seat
- 2-way Globe
- 2/2-way
- Acid Cation Conductivity
- Activated Sludge
- Aluminum
- Ammonia Gas Detector
- Ammonium
- Angle Seat Valves
- Bromine
- Calibration Gas
- Calibration Gas Generator
- Cation Conductivity
- Chemical Feed Pumps
- Chemical Oxygen Demand
- Chemical Pumps (Hazardous Duty)
- Chloride
- Chlorine (Combined)
- Chlorine (Free)
- Chlorine (Residual)
- Chlorine (Total)
- Chlorine Dioxide
- Colour of Water
- Combustible Gas Detector
- Conductivity
- Decentralized Automation
- Degassed Cation Conductivity
- Dewpoint
- Dewpoint (Hazardous Location)
- Diaphragm Valve
- Dichloramine
- Dissolved Hydrogen
- Dissolved Iron
- Dissolved Oxygen
- Dissolved Ozone
- DPD
- DPD and Reagents
- Explosion Proof Pressure Gauges
- Explosion Proof Temperature Sensors
- Float Level Switches
- Flow Meter (Coriolis)
- Flow Meters (Magnetic)
- Flow Meters (Paddle Wheel)
- Fluoride
- FMI Pumps
- Fuels
- Full Directory
- Globe Valve
- Guided Radar Level
- HAA
- High Purity Water
- Hydrazine
- Hydrocarbons
- Iodine
- Ion Selective Electrodes
- Level
- Level Measurement
- Low Level Turbidity
- Manganese
- Modular Gas Detector
- Monochloramine
- Multi Parameters
- Nitrate
- Non-Contact Level
- OIl in Water
- ORP
- Ozone
- Pendulum Level Switches
- pH
- Phosphate
- Pneumatic Valve Units
- Pneumatically operated
- Portable Gas Detector
- Power
- Pressure Gauges
- Pure Water
- Radar Level
- Redox
- Salinity
- Sample Conditioning
- Sensors
- Silica
- Sludge Blanket
- Sodium
- Solenoid valves
- Solenoid valves Hazardous
- Specialty Pumps (Dispensing, OEM)
- Specialty Pumps (Dispensing)
- Specialty Pumps (Metering, OEM)
- Specialty Pumps (Metering)
- Specialty Pumps (Waste Transfer)
- Specific Conductivity
- Specific Resistivity
- Steam Cycle
- Suspended Solids
- TDS
- Technical Article
- Temperature
- Temperature Sensors
- THM
- TOC
- Total Alkalinity
- Total Conductivity
- Total Dissolved Solids
- Total Hardness
- Total Iron
- Total Organic Carbon
- Toxic Gas Detector
- Trihalomethanes
- Turbidity
- Ultrasonic Level
- Universal Gas Detector
- UVT
- VOC
- Water Hardness
- Water Treatment Controller
- Wet Gas Detector
Guided Radar Level measurement interchangeable cable, rod, or coax probes, continuous measurement in various industrial liquid applications.
Radar Level Type 8137 is a non-contact radar level meter designed for continuous level measurement. This unit is available in two variants:
Ultrasonic Level for Continuous Non-Contact Measurement in both open and closed vessels. Suitable for liquids and solids, in all industries.
2-way Globe Control Valve fulfills tough criteria for process environments. Unrivaled cycle life and sealing integrity.
2-way Angle Seat Control Valve meets the stringent demands of process environments. Exceptional durability, unrivaled cycle life.
Diaphragm valve externally controlled Type 2103 consists of a SS pneumatically operated piston actuator, a diaphragm and a 2-way valve body.
Angle seat valve (2100). Specifically optimized for decentralized process automation, meeting the stringent demands of process environments.
Angle seat valve (2100). Specifically optimized for decentralized process automation, meeting the stringent demands of process environments.
Angle seat valve (2100). Specifically optimized for decentralized process automation, meeting the stringent demands of process environments.
Angle seat valve (2100). Specifically optimized for decentralized process automation, meeting the stringent demands of process environments.
Type 2000 Angle seat valve. Externally piloted, operated with a single or double-acting piston actuator. Available in two different materials.
Walchem Water Treatment Controller with powerful built-in algorithms for control of metering pumps and valves from multiple sensor inputs.
pH and Redox (ORP) potential in potable water and effluents. Dual channel monitor for continuous measurement.
Combustible Gas Detector system eliminates the need for frequent response checks with ATi’s pioneering AutoTest. This transmitter performs an automatic test using self-generated gas on…
The revolutionary SWAN AMI Turbiwell LED online turbidity analyzer boasts unique features not found in other turbidity analyzers. The non-contact, EPA approved white light LED…
The Hanna Turbidity and Chlorine HI93414 is a high accuracy Handheld analyzer. Combining nephelometer and photometer to measure key parameters in drinking water. calibration and…
Chlorine monitoring system, provides monitoring for several species of disinfectants with one instrument. The instrument can monitor for free chlorine and total chlorine, and can…
Detection of combustible levels of methane or other hydrocarbons % LEL. It may also be used for monitoring CO2 levels, either in ppm or percent…
Complete monitoring system for the automatic, continuous measurement of ortho- phosphate in boiler water, district heating, cooling water and waste water. Measuring range: 0.1 to…
The OxyTechw² GAL Sensor has been designed to provide highly reliable Dissolved Oxygen measurements. The sensor employs the traditional galvanic principle. The rugged 100 micron,…
Direct–acting Type 6014 valve for individual or manifold mounting with push–over coil, for use with a variety media depending on the materials of construction. Delivered…
Servo-assisted solenoid valve with diaphragm, normally closed function. Hermetic isolation of fluid from the actuator. A minimum differential pressure of 7 PSI is required to…
The Type 5282 is a pilot-controlled normally closed solenoid valve with a servo-diaphragm, media separated, for universal use with liquid and gaseous media corresponding to…
The Type 6213 is a 2/2–way normally closed solenoid valve with a forced coupled diaphragm system. It switches from 1.5 PSI and can be used…
The TurbiTechw² HR Sensor has been specifically designed for use in wastewater treatment systems where high levels of suspended solids are desirable in the aeration…
The TurbiTechw² LA Sensor has been designed for use in aeration systems monitoring suspended solids also known as mixed liquor suspended solids or activated sludge…
The ASLD2200 is a fully automatic sludge blanket level detector designed for the water and waste water industry. It utilises a servo-driven sensor which continually…
The SludgeWatch Ultra utilizes the industry accepted look down ultrasonic or ‘sonar’ method of detecting and tracking the interface between sludge and water in water,…
The SludgeWatch 8200w² Monitor provides a reliable method of detecting the sludge blanket level in clarifiers and settlement tanks, or increasing levels of suspended solids…
The SludgeWatch 715 provides a simple, low cost method of spot checking the sludge blanket level in a wide variety of settlement tanks. The cable…
UVT Monitor – UV Transmittance at 254 nm SWAN AMI SAC 254 UVT Monitor for the continuous measurement of UV transmittance absorption at 254 nm…
Online Phosphate Analyzer AMI Phosphate-II AC Online Phosphate Analyzer using the colorimetric process for the automatic, continuous measurement of phosphate. Call Contact Description Specification Application…
An electronic transmitter for continuous pH or redox (ORP) measurements for water steam cycle, potable water, high purity water or waste water. The size of…
Meridian Universal Gas Detector Teledyne The Meridian Universal Gas Detector is one detector with global approvals and a plug-and-play design, for toxic and combustible gases…
Wet H2S gas monitor is a new type of gas sensor technology that allows continuous monitoring of hydrogen sulfide in both inlet and discharge air,…
ATi’s E12-15 IR Infrared High Level Ammonia Gas Detector is a rugged, reliable, microprocessor-based, intelligent gas detector. The E12-15 IR can be used to monitor…
A14/A11 Modular Gas Detector is a flexible component system providing a variety of options to meet individual gas detection and alarm requirements. From chemical and…
Locating the source of gas leaks can be a challenge, especially in plant areas with multiple potential leak sources. Ammonia refrigeration piping, ozone generator skids,…
B12 Wet Gas System was developed to meet the need for reliable measurements in wet scrubber outlets for other gas streams that might be saturated…
ATI’s Series F12/D provides a high level of confidence that your system is functional at all times. Our Auto-Test feature provides an actual gas “bump…
Our UniSens universal 2-wire gas transmitter handles 28 different gases, providing the most economical and flexible gas measurement system available today. Combining universal electronics, bench…
The MS1800 is a VOC and Hydrocarbon Gas Concentration Analyzer. It is designed to monitor VOC gases in industrial processes and applications as well as…
The high performance Coriolis mass flow meter distinguishes itself from the competition because we are able to achieve higher flow rates and mass flow measurements…
The EPS offers several advantages over similar models. It is designed specifically for reliability and longevity in harsh environments, comes in a wide variety of…
The MIST M340 RTD Temperature Transmitter consists of surface mount ring type RTD, extension cable to remote transmitter and M12 connector. It is designed for…
Dial Thermometers are mechanical temperature indicators consisting of a pointer precisely connected to a bimetal helix stem which moves due to temperature changes in the…
PTS® Series (Programmable Temperature Switches) are of very compact design. This unique construction can replace other commonly used temperature switches in a variety of applications.…
The PTS®201 is a microprocessor-based wall mounted temperature switch. It features stainless RTD probe, painted aluminum die cast housing in which electronics are potted. Based…
Stainless Steel NEMA 4X Housing Battery Powered, Loop 2-wire Powered & 3-wire Powered 4-20mA Available with 2 and 3-wire LED or LCD Display Matched Pairs…
Series PTS02 is a Programmable Temperature Switch & Transmitter offering an analog 4-20 mA output, transistor or relay switch output, and an optional RTD output.…