wjf-logo
1 877 291 5572    |    Contact Us    |    Search

Explosion Proof Temperature Switch & Transmitter | Programmable

PTS02 Temperature Switch

Series PTS02 is a Programmable Temperature Switch & Transmitter offering an analog 4-20 mA output, transistor or relay switch output, and an optional RTD output.

Series PTS02 is a Programmable Temperature Switch & Transmitter offering an analog 4-20 mA output, transistor or relay switch output, and an optional RTD output.

Series PTS02 is a Programmable Explosion Proof Temperature Switch & Transmitter offering an analog 4-20 mA output, transistor or relay switch output, and an optional RTD output. Utilizing Intempco’s patented MIST technology, PTS02 is designed for optimum accuracy and performance. The main areas of applications for this transducer are oil and gas as well as other hazardous areas.

PTS02 is shipped factory calibrated to customer specified temperature ranges. But the unique feature of the PTS02 is that it is re-programmable. Process temperature or alarm change? No problem! Simply use PTS02-PKIT interface module and re-range your PTS without the need to recalibrate and without the loss of accuracy. PTS02 is much more accurate than an RTD and a separate indicator / transmitter or switch.

When the PTS02 is re-scaled to a different temperature range, the calibrated default values are not lost. This transducer can be re-calibrated by performing one-point or two-point calibration using known temperature standards. This is where the PTS02 leaves the competition behind. Indicating temperature range, current output, switch set point, switching hysterises, switch logic, damping and other features are all programmable.

The PTS02 wetted parts, as well as the housing, are fabricated from 316 stainless construction. Other materials, various probe diameters, fitting sizes and thermowell types are available. For electrical connection, a 1/2” NPT conduit with lead wires is standard. The sensing element used is Pt-100 Ohm RTD Class A. PTS02 can be made available with an additional 3-wire RTD output. This feature allows a single process connection to be used for indication of temperature and for remote indication, recording, or controlling. Each PTS02 has the part number, range and serial number marked on the transmitter housing.

If you require an accurate, stable and dependable temperature transducer, look no further. Model PTS02 is your solution.

This product is protected under US patent 7,223,014 and CDN patent 2,561,570.

Explosion Proof Temperature Switch Features

  • CSA Class I Div. 1 Explosion Proof
  • Available 4-20 mA or voltage programmable signal output
  • Available fully programmable switch output; relay or transistor
    Field re-programmable with optional PC interface module & software
  • Security password and tracking protection for re-programming and re-calibration
  • Utilizes self-calibration feature for accurate and stable performance
  • Utilizes Pt-100 Ohm RTD Class A element for temperature sensing
  • Excellent long term properties
  • Standard SS316/SS316L construction
  • Type 4X, IP66/IP67 rated environmental protection
  • Easy installation with various mounting configurations

Explosion Proof Temperature Switch Custom Builder : Probe/Tube Type Design. (Thermowell Type Below)

Explosion Proof Temperature Switch
Explosion Proof Temperature Switch 0
Explosion Proof Temperature Switch 1
Explosion Proof Temperature Switch 2
Explosion Proof Temperature Switch 4
Explosion Proof Temperature Switch 7
Explosion Proof Temperature Switch 10
Explosion Proof Temperature Switch 11
Explosion Proof Temperature Switch 12

Explosion Proof Temperature Switch Custom Builder : Threaded Thermowell Design

Thermowell Design Temperature
Thermowell Design Temperature 0
Thermowell Design Temperature 1
Thermowell Design Temperature 2
Thermowell Design Temperature 2b
Thermowell Design Temperature 3
Thermowell Design Temperature 4
Thermowell Design Temperature 5
Thermowell Design Temperature 6
Thermowell Design Temperature 7
Thermowell Design Temperature 8
Thermowell Design Temperature 9
Thermowell Design Temperature
Thermowell Design Temperature 11
Thermowell Design Temperature 12

Technical Specifications – 3-wire outputs & switching

Explosion Proof Temperature Switch Electrical Properties
Sensing ElementRTD, Type Pt100 DIN EN6075, Class A
Sensor Current< 0.25 mA
Temperature RangesCustomer re-scalable between –50 ºC to 200 ºC depending on model. No re-calibration required.
Switching RangesCustomer programmable between –50 ºC to 200 ºC depending on model.
HysteresisCustomer programmable, 1% of range by factory setting.
Accuracy± ( .25 ºC + 0.40 % of span ) with one-point calibration 1.
± ( .10 ºC + 0.10 % of calibrated span ) with two-point calibration 2.
Open circuit detection Upscale ( 22 mA ) or Downscale ( 2.5 mA ) current output.
Warm-up30 seconds.
Response Time0.5 sec to 30 sec ( software selectable )
RFI effect1 % or less typical
Temp. Effect± 0.001% of span / º C deviation from 25 ºC
Power Supply12-32 VDC, polarity protected
Supply effect0.005 % / V
Power consumption15 mA @ 24 VDC + output current – 950 mW max.
20 mA @ 24 VDC for NPN output – 500 mW max.
20 mA @ 24 VDC + sourcing current for PNP output
50 mA @ 24 VDC for Relay Output – 1200 mW max.
Current Output4-20 mA ( 3 wires configuration ) linear to temperature.
Max load on current output[ ( Vsupply – 7V ) /20 mA ] ohms
Switching OutputTransistor NPN – max. 50 mA @ 24 VDC sink current
Transistor PNP – max. 50 mA @ 24 VDC source current
Relay SPDT 0.5A @ 120 VAC
Switching LogicN.C. or N.O. software selectable.
Isolation500 VDC Input / Output ( between probe and output signal )
Electrical ConnectionMulti-conductor cable or single conductors, potted and sealed ,minimum conductor size 22 ga
Mechanical Properties
Ambient Temp. Range– 40 ºC to 80 ºC ( -40 ºF to 176 ºF )
Storage Temp. Range– 50 ºC to 85 ºC ( -58 ºF to 185 ºF )
Max. PressureThermowell design 6000 PSI
Probe/Tube type designUp to 3000 PSI, depending on tube diameter.
Consult factory for application. ( applies to sensor portion only )
Housing MaterialStainless steel 316/316L standard, others available
Probe MaterialStainless steel 316/316L standard, others available
Cable MaterialsSilicone, Teflon®, SS armor or SS overbraid over Teflon®
Cable LengthMaximum supplied cable length on sensor is 1200 inches.
Environmental ProtectionType 4X , IP66/IP67. Potted electronics.
Installation Considerations

Installation requirements of the PTS are similar to those of the temperature sensor assemblies with head mounted hockey puck transmitter. If the temperature of the electronics in the housing exceeds 80 ºC, permanent damage to the PTS may occur. In all applications, especially those close to 200 ºC, careful attention must be placed on correct installation. It is the installer’s, customer’s and/or end user’s responsibility to make sure that this over exposure to temperature does not occur due to improper installation.

Technical Specifications : 2-wire and 3-wire voltage outputs

Electrical Properties
Sensing ElementRTD, Type Pt100 DIN EN6075, Class A
Sensor Current< 0.25 mA
Sensor Temperature RangesSee Box1 code for standard ranges. Field re-scalable between or -50 ºC to 200 ºC
Outputs4-20 mA loop powered, 2-wire, linear to temperature
0-5 VDC, 1-5 VDC, 0-10 VDC all 3-wire, linear to temperature
Minimum Input Impedance1000 Ohm ( of measuring device, for voltage output )
Power Supply12-32 VDC, polarity protected
Supply Effect0.001 % / V
Accuracy± ( .25 ºC + 0.40 % of span ) with one-point calibration 1.
± ( .10 ºC + 0.10 % of calibrated span ) with two-point calibration 2.
Maximum Loop Resistance[ ( Vsupply – 7V ) /20 mA ] ohms ( for 4-20 mA output only )
Sensor Open CircuitUpscale 24 mA or Downscale 2.5 mA ( for 4-20 mA output only )
Warmup30 seconds
RFI Effect1 % or less typical
Isolation500 VDC Input / Output
Temp. Effects± 0.001 % of Span / ºC deviation from 25 ºC
Long Term Drift≤ 0.1 % FS / Year
Mechanical Properties
Ambient Temp. Range– 40 ºC to 80 ºC ( -40 ºF to 176 ºF )
Storage Temp. Range– 50 ºC to 85 ºC ( -58 ºF to 185 ºF )
Max. PressureThermowell design : 6000 PSI
Probe/Tube type design Up to 3000 PSI, depending on tube diameter.
Consult factory for application. ( applies to sensor portion only )
Housing MaterialStainless steel 316/316L standard, others available.
Probe MaterialStainless steel 316/316L standard, others available.
Cable MaterialsSilicone, Teflon®, SS armor or SS overbraid over Teflon®
Cable LengthMaximum supplied cable length on sensor is 1200 inches.
Environmental ProtectionType 4X , IP66/IP67. Potted electronics.
Installation Considerations

Installation requirements of the PTS are similar to those of the temperature sensor assemblies with head mounted hockey puck transmitter. If the temperature of the electronics in the housing exceeds 80 ºC, permanent damage to the PTS may occur. In all applications, especially those close to 200 ºC, careful attention must be placed on correct installation. It is the installer’s, customer’s and/or end user’s responsibility to make sure that this over exposure to temperature does not occur due to improper installation.

Teflon® is a registered trademark of E.I. du Pont de Nemours and Company.
1. Max. error on complete span. Error at calibration point ≤ 0.1 % of Span.
2. Max. error on complete calibrated span. Error at calibration points ≤ 0.1 % of Span.
• Information furnished by Intempco is believed to be accurate and reliable. However, no responsability is assumed by Intempco for its use.
• Specifications subject to change without notice

Description

Series PTS02 is a Programmable Explosion Proof Temperature Switch & Transmitter offering an analog 4-20 mA output, transistor or relay switch output, and an optional RTD output. Utilizing Intempco’s patented MIST technology, PTS02 is designed for optimum accuracy and performance. The main areas of applications for this transducer are oil and gas as well as other hazardous areas.

PTS02 is shipped factory calibrated to customer specified temperature ranges. But the unique feature of the PTS02 is that it is re-programmable. Process temperature or alarm change? No problem! Simply use PTS02-PKIT interface module and re-range your PTS without the need to recalibrate and without the loss of accuracy. PTS02 is much more accurate than an RTD and a separate indicator / transmitter or switch.

When the PTS02 is re-scaled to a different temperature range, the calibrated default values are not lost. This transducer can be re-calibrated by performing one-point or two-point calibration using known temperature standards. This is where the PTS02 leaves the competition behind. Indicating temperature range, current output, switch set point, switching hysterises, switch logic, damping and other features are all programmable.

The PTS02 wetted parts, as well as the housing, are fabricated from 316 stainless construction. Other materials, various probe diameters, fitting sizes and thermowell types are available. For electrical connection, a 1/2” NPT conduit with lead wires is standard. The sensing element used is Pt-100 Ohm RTD Class A. PTS02 can be made available with an additional 3-wire RTD output. This feature allows a single process connection to be used for indication of temperature and for remote indication, recording, or controlling. Each PTS02 has the part number, range and serial number marked on the transmitter housing.

If you require an accurate, stable and dependable temperature transducer, look no further. Model PTS02 is your solution.

This product is protected under US patent 7,223,014 and CDN patent 2,561,570.

Explosion Proof Temperature Switch Features

  • CSA Class I Div. 1 Explosion Proof
  • Available 4-20 mA or voltage programmable signal output
  • Available fully programmable switch output; relay or transistor
    Field re-programmable with optional PC interface module & software
  • Security password and tracking protection for re-programming and re-calibration
  • Utilizes self-calibration feature for accurate and stable performance
  • Utilizes Pt-100 Ohm RTD Class A element for temperature sensing
  • Excellent long term properties
  • Standard SS316/SS316L construction
  • Type 4X, IP66/IP67 rated environmental protection
  • Easy installation with various mounting configurations
Options

Explosion Proof Temperature Switch Custom Builder : Probe/Tube Type Design. (Thermowell Type Below)

Explosion Proof Temperature Switch
Explosion Proof Temperature Switch 0
Explosion Proof Temperature Switch 1
Explosion Proof Temperature Switch 2
Explosion Proof Temperature Switch 4
Explosion Proof Temperature Switch 7
Explosion Proof Temperature Switch 10
Explosion Proof Temperature Switch 11
Explosion Proof Temperature Switch 12

Explosion Proof Temperature Switch Custom Builder : Threaded Thermowell Design

Thermowell Design Temperature
Thermowell Design Temperature 0
Thermowell Design Temperature 1
Thermowell Design Temperature 2
Thermowell Design Temperature 2b
Thermowell Design Temperature 3
Thermowell Design Temperature 4
Thermowell Design Temperature 5
Thermowell Design Temperature 6
Thermowell Design Temperature 7
Thermowell Design Temperature 8
Thermowell Design Temperature 9
Thermowell Design Temperature
Thermowell Design Temperature 11
Thermowell Design Temperature 12
Specifications

Technical Specifications – 3-wire outputs & switching

Explosion Proof Temperature Switch Electrical Properties
Sensing ElementRTD, Type Pt100 DIN EN6075, Class A
Sensor Current< 0.25 mA
Temperature RangesCustomer re-scalable between –50 ºC to 200 ºC depending on model. No re-calibration required.
Switching RangesCustomer programmable between –50 ºC to 200 ºC depending on model.
HysteresisCustomer programmable, 1% of range by factory setting.
Accuracy± ( .25 ºC + 0.40 % of span ) with one-point calibration 1.
± ( .10 ºC + 0.10 % of calibrated span ) with two-point calibration 2.
Open circuit detection Upscale ( 22 mA ) or Downscale ( 2.5 mA ) current output.
Warm-up30 seconds.
Response Time0.5 sec to 30 sec ( software selectable )
RFI effect1 % or less typical
Temp. Effect± 0.001% of span / º C deviation from 25 ºC
Power Supply12-32 VDC, polarity protected
Supply effect0.005 % / V
Power consumption15 mA @ 24 VDC + output current – 950 mW max.
20 mA @ 24 VDC for NPN output – 500 mW max.
20 mA @ 24 VDC + sourcing current for PNP output
50 mA @ 24 VDC for Relay Output – 1200 mW max.
Current Output4-20 mA ( 3 wires configuration ) linear to temperature.
Max load on current output[ ( Vsupply – 7V ) /20 mA ] ohms
Switching OutputTransistor NPN – max. 50 mA @ 24 VDC sink current
Transistor PNP – max. 50 mA @ 24 VDC source current
Relay SPDT 0.5A @ 120 VAC
Switching LogicN.C. or N.O. software selectable.
Isolation500 VDC Input / Output ( between probe and output signal )
Electrical ConnectionMulti-conductor cable or single conductors, potted and sealed ,minimum conductor size 22 ga
Mechanical Properties
Ambient Temp. Range– 40 ºC to 80 ºC ( -40 ºF to 176 ºF )
Storage Temp. Range– 50 ºC to 85 ºC ( -58 ºF to 185 ºF )
Max. PressureThermowell design 6000 PSI
Probe/Tube type designUp to 3000 PSI, depending on tube diameter.
Consult factory for application. ( applies to sensor portion only )
Housing MaterialStainless steel 316/316L standard, others available
Probe MaterialStainless steel 316/316L standard, others available
Cable MaterialsSilicone, Teflon®, SS armor or SS overbraid over Teflon®
Cable LengthMaximum supplied cable length on sensor is 1200 inches.
Environmental ProtectionType 4X , IP66/IP67. Potted electronics.
Installation Considerations

Installation requirements of the PTS are similar to those of the temperature sensor assemblies with head mounted hockey puck transmitter. If the temperature of the electronics in the housing exceeds 80 ºC, permanent damage to the PTS may occur. In all applications, especially those close to 200 ºC, careful attention must be placed on correct installation. It is the installer’s, customer’s and/or end user’s responsibility to make sure that this over exposure to temperature does not occur due to improper installation.

Technical Specifications : 2-wire and 3-wire voltage outputs

Electrical Properties
Sensing ElementRTD, Type Pt100 DIN EN6075, Class A
Sensor Current< 0.25 mA
Sensor Temperature RangesSee Box1 code for standard ranges. Field re-scalable between or -50 ºC to 200 ºC
Outputs4-20 mA loop powered, 2-wire, linear to temperature
0-5 VDC, 1-5 VDC, 0-10 VDC all 3-wire, linear to temperature
Minimum Input Impedance1000 Ohm ( of measuring device, for voltage output )
Power Supply12-32 VDC, polarity protected
Supply Effect0.001 % / V
Accuracy± ( .25 ºC + 0.40 % of span ) with one-point calibration 1.
± ( .10 ºC + 0.10 % of calibrated span ) with two-point calibration 2.
Maximum Loop Resistance[ ( Vsupply – 7V ) /20 mA ] ohms ( for 4-20 mA output only )
Sensor Open CircuitUpscale 24 mA or Downscale 2.5 mA ( for 4-20 mA output only )
Warmup30 seconds
RFI Effect1 % or less typical
Isolation500 VDC Input / Output
Temp. Effects± 0.001 % of Span / ºC deviation from 25 ºC
Long Term Drift≤ 0.1 % FS / Year
Mechanical Properties
Ambient Temp. Range– 40 ºC to 80 ºC ( -40 ºF to 176 ºF )
Storage Temp. Range– 50 ºC to 85 ºC ( -58 ºF to 185 ºF )
Max. PressureThermowell design : 6000 PSI
Probe/Tube type design Up to 3000 PSI, depending on tube diameter.
Consult factory for application. ( applies to sensor portion only )
Housing MaterialStainless steel 316/316L standard, others available.
Probe MaterialStainless steel 316/316L standard, others available.
Cable MaterialsSilicone, Teflon®, SS armor or SS overbraid over Teflon®
Cable LengthMaximum supplied cable length on sensor is 1200 inches.
Environmental ProtectionType 4X , IP66/IP67. Potted electronics.
Installation Considerations

Installation requirements of the PTS are similar to those of the temperature sensor assemblies with head mounted hockey puck transmitter. If the temperature of the electronics in the housing exceeds 80 ºC, permanent damage to the PTS may occur. In all applications, especially those close to 200 ºC, careful attention must be placed on correct installation. It is the installer’s, customer’s and/or end user’s responsibility to make sure that this over exposure to temperature does not occur due to improper installation.

Teflon® is a registered trademark of E.I. du Pont de Nemours and Company.
1. Max. error on complete span. Error at calibration point ≤ 0.1 % of Span.
2. Max. error on complete calibrated span. Error at calibration points ≤ 0.1 % of Span.
• Information furnished by Intempco is believed to be accurate and reliable. However, no responsability is assumed by Intempco for its use.
• Specifications subject to change without notice

Downloads