Home > Temperature > Coriolis Mass Flow Meter
The Heinrichs TMU high performance Coriolis mass flow meter distinguishes itself from the competition because we are able to achieve higher flow rates and mass flow measurements in larger line sizes than other mass flow meter providers. With the TMU, we have achieved accurate mass flow measurements up to 2,200 metric tons per hour in line sizes up to 16 inches.
It has a very accurate, rugged design built for mass flow measurements of liquids and gases in most chemical, petrochemical, oil and gas applications.
Mass flow, density and temperature are simultaneously measured, and volumetric flow is computed from these parameters.
The flow meter’s wetted materials (fittings and measuring tubes) are available in 316L stainless steel or Hastelloy® C-22 with other materials available on request.
There are no moving parts to wear out, and the measuring tubes and sensors are protected by a very rugged, all-welded housing. The TMU employs a highly effective measuring tube de-coupling system that virtually eliminates errors caused by piping-induced vibrations and stresses. This allows the flow meter to provide very accurate mass flow measurements in the most demanding applications.
The TMU is the clear choice if you require mass flow measurements of very high flows in large line sizes.
The Mass Flow Meter model TMU utilizes the Coriolis principle of operation to measure mass flow. Density and temperature are simultaneously monitored and volumetric flow is additionally calculated with these parameters. The TMU Series is available with a direct mounted transmitter or in a remote mounted configuration. The unit can be used to meter nearly all liquid or gaseous media and was especially designed to operate in many standard applications. It is applied in many different industrial branches. The TMU Series is also used for precise dosing as well as in loading and unloading applications. Approvals for service in custody transfer (fiscal metering) applications are also available.
Application Areas
Measuring principle: | Coriolis |
Measurable media: | liquids and gases |
Materials – flow tubes, splitter, | |
flanges: | stainless steel 1.4404 (316 L) / 1.4571 (316 Ti) Hastelloy C-22 |
– housing: | stainless steel 1.4301 (304) up to TMU-x040 St 37.2 /1.4301 (304) from TMU-x050 |
Process connections: | acc. to EN 1092, ASME B16.5, DIN 2512, special connections on request |
Nominal pressure: | PN 40, ASME Cl 150 / 300 higher pressures on request |
Process temperature: | -40 … +260 °C |
Ambient temperature: | -20 … +60 °C (standard) -20 …+80 °C (as special version) |
Protection: | IP 66/68 (EN60529) |
Certificates and approvals | |
– explosion protection: | sensor circuits: intrinsically safe DMT 01 ATEX E 149 X II ½ G EEx ia IIC T6–T2 (approval for zone 0 inside flow tubes available) |
– CE-marking: | pressure equipment directive 97 / 23 / EG |
Material | |
– housing: | aluminium (painted) |
– display cover: | safety glass |
Mounting: | integrated or remote mounted (junction box or plug in connector) |
Power supply: | 19 – 36 VDC, 24 VAC ±20 %, 90 – 265 VAC |
Outputs: | galvanically isolated |
Current: | 2 x 0 (4) – 20 mA |
Binary 1: | active, potential free 24 V =, max. 200 mA passive, optocoupler, Ui = 30 V, Ii = 200 mA, Pi = 3 W |
Frequency: | 1 KHz |
Binary 2: | passive, optocoupler, Ui = 30 V, Ii = 200 mA, Pi = 3 W |
Status: | passive, optocoupler, Ui = 30 V, Ii = 200 mA, Pi = 3 W |
Input binary: | counter reset |
Ambient temperature: | -20 … +60 °C (standard) -20 … +80 °C (remote mounted transmitter with appovals 5 and 6) |
Protection: | IP 68 (EN60529) |
Communication: | HART® Profibus® PA Fieldbus® Foundation™ Modbus RTU (RS 485) |
Material | |
– housing: | aluminium (painted) |
Mounting: | integrated or remote mounted (junction box or cable) |
Power supply: | 19 – 36 VDC 24 VAC + 5 % / -20 %, 50 / 60 Hz 90 – 265 VAC, 50 / 60 Hz |
Output signals | |
All signal outputs: | galvanically isolated |
Analogue output: | 2 x 4 – 20 mA passive Current output 1: mass flow, volume flow, density, temperature (when using HART® protocol, output 1 is assigned to mass flow) Current output 2: mass flow, volume flow, density, temperature |
Pulse output | |
Binary 1: | pulse duration, standard 50 ms, adjustable from 0,1 … 2000 ms pulse/pause ratio 1:1 (if the set pulse duration is below limit) as frequency output: max. 1 KHz passive, optocoupler, Unom: 24 V, Ui = 30 V, Ii = 60 mA, Pi = 1,8 W |
Pulse value: | settable in decade increments of selected pulse unit (e. g. kg or m³) |
Status: | forward flow, reverse flow, Min. / Max. flow rate, Min. / Max. density, Min. / Max. temperature, alarm, second pulse output (out of phase by 90°) passive, optocoupler, Unom: 24 V, Ui = 30 V, Ii = 60 mA, Pi = 1,8 W |
Ambient temperature: | -20 … +60 °C (standard) below 0 °C the readability of the LC-display is limited |
Protection: | IP 68 (EN60529) |
Communication: | HART® |
Liquid: | ±0,1 % of reading ±zero point stability up to TMU-x040 ±0,15 % of reading ±zero point stability from TMU-x050 |
Gas: | ±0,5 % of reading ±zero point stability |
Density (liquid): | ±0,005 g/cm³ with density calibration ±0,001 g/cm³ with special density calibration for TMU-x015, TMU-x025 and TMU-x040 ±0,002 g/cm³ with special density calibration for other models |
Volume: | ±0,2 % of reading ±zero point stability |
Sensor |
Instrisically safe sensor circuits |
DMT 01 ATEX E 149 X |
II 1/2 G Ex ia IIC T6 – T2 |
(Zone 0 is permitted in the measuring tube) |
NEPSI Approval Cert. No. GYJ06476X |
GOST-R |
UMC-3 |
BVS 05 ATEX E 021 X |
II (1)2G EEx de [ia] IIC/IIB T6–T3 |
II (1)2G EEx d [ia] IIC/IIB T6–T3 |
NEPSI Approval Cert. No. GYJ06477 |
GOST-R |
UMC-4 |
BVS 10 ATEX E 110 X |
II (1)2G Ex d [ia Ga] IIC T4–T3 Gb |
IEC-Ex |
The Heinrichs TMU high performance Coriolis mass flow meter distinguishes itself from the competition because we are able to achieve higher flow rates and mass flow measurements in larger line sizes than other mass flow meter providers. With the TMU, we have achieved accurate mass flow measurements up to 2,200 metric tons per hour in line sizes up to 16 inches.
It has a very accurate, rugged design built for mass flow measurements of liquids and gases in most chemical, petrochemical, oil and gas applications.
Mass flow, density and temperature are simultaneously measured, and volumetric flow is computed from these parameters.
The flow meter’s wetted materials (fittings and measuring tubes) are available in 316L stainless steel or Hastelloy® C-22 with other materials available on request.
There are no moving parts to wear out, and the measuring tubes and sensors are protected by a very rugged, all-welded housing. The TMU employs a highly effective measuring tube de-coupling system that virtually eliminates errors caused by piping-induced vibrations and stresses. This allows the flow meter to provide very accurate mass flow measurements in the most demanding applications.
The TMU is the clear choice if you require mass flow measurements of very high flows in large line sizes.
The Mass Flow Meter model TMU utilizes the Coriolis principle of operation to measure mass flow. Density and temperature are simultaneously monitored and volumetric flow is additionally calculated with these parameters. The TMU Series is available with a direct mounted transmitter or in a remote mounted configuration. The unit can be used to meter nearly all liquid or gaseous media and was especially designed to operate in many standard applications. It is applied in many different industrial branches. The TMU Series is also used for precise dosing as well as in loading and unloading applications. Approvals for service in custody transfer (fiscal metering) applications are also available.
Application Areas
Measuring principle: | Coriolis |
Measurable media: | liquids and gases |
Materials – flow tubes, splitter, | |
flanges: | stainless steel 1.4404 (316 L) / 1.4571 (316 Ti) Hastelloy C-22 |
– housing: | stainless steel 1.4301 (304) up to TMU-x040 St 37.2 /1.4301 (304) from TMU-x050 |
Process connections: | acc. to EN 1092, ASME B16.5, DIN 2512, special connections on request |
Nominal pressure: | PN 40, ASME Cl 150 / 300 higher pressures on request |
Process temperature: | -40 … +260 °C |
Ambient temperature: | -20 … +60 °C (standard) -20 …+80 °C (as special version) |
Protection: | IP 66/68 (EN60529) |
Certificates and approvals | |
– explosion protection: | sensor circuits: intrinsically safe DMT 01 ATEX E 149 X II ½ G EEx ia IIC T6–T2 (approval for zone 0 inside flow tubes available) |
– CE-marking: | pressure equipment directive 97 / 23 / EG |
Material | |
– housing: | aluminium (painted) |
– display cover: | safety glass |
Mounting: | integrated or remote mounted (junction box or plug in connector) |
Power supply: | 19 – 36 VDC, 24 VAC ±20 %, 90 – 265 VAC |
Outputs: | galvanically isolated |
Current: | 2 x 0 (4) – 20 mA |
Binary 1: | active, potential free 24 V =, max. 200 mA passive, optocoupler, Ui = 30 V, Ii = 200 mA, Pi = 3 W |
Frequency: | 1 KHz |
Binary 2: | passive, optocoupler, Ui = 30 V, Ii = 200 mA, Pi = 3 W |
Status: | passive, optocoupler, Ui = 30 V, Ii = 200 mA, Pi = 3 W |
Input binary: | counter reset |
Ambient temperature: | -20 … +60 °C (standard) -20 … +80 °C (remote mounted transmitter with appovals 5 and 6) |
Protection: | IP 68 (EN60529) |
Communication: | HART® Profibus® PA Fieldbus® Foundation™ Modbus RTU (RS 485) |
Material | |
– housing: | aluminium (painted) |
Mounting: | integrated or remote mounted (junction box or cable) |
Power supply: | 19 – 36 VDC 24 VAC + 5 % / -20 %, 50 / 60 Hz 90 – 265 VAC, 50 / 60 Hz |
Output signals | |
All signal outputs: | galvanically isolated |
Analogue output: | 2 x 4 – 20 mA passive Current output 1: mass flow, volume flow, density, temperature (when using HART® protocol, output 1 is assigned to mass flow) Current output 2: mass flow, volume flow, density, temperature |
Pulse output | |
Binary 1: | pulse duration, standard 50 ms, adjustable from 0,1 … 2000 ms pulse/pause ratio 1:1 (if the set pulse duration is below limit) as frequency output: max. 1 KHz passive, optocoupler, Unom: 24 V, Ui = 30 V, Ii = 60 mA, Pi = 1,8 W |
Pulse value: | settable in decade increments of selected pulse unit (e. g. kg or m³) |
Status: | forward flow, reverse flow, Min. / Max. flow rate, Min. / Max. density, Min. / Max. temperature, alarm, second pulse output (out of phase by 90°) passive, optocoupler, Unom: 24 V, Ui = 30 V, Ii = 60 mA, Pi = 1,8 W |
Ambient temperature: | -20 … +60 °C (standard) below 0 °C the readability of the LC-display is limited |
Protection: | IP 68 (EN60529) |
Communication: | HART® |
Liquid: | ±0,1 % of reading ±zero point stability up to TMU-x040 ±0,15 % of reading ±zero point stability from TMU-x050 |
Gas: | ±0,5 % of reading ±zero point stability |
Density (liquid): | ±0,005 g/cm³ with density calibration ±0,001 g/cm³ with special density calibration for TMU-x015, TMU-x025 and TMU-x040 ±0,002 g/cm³ with special density calibration for other models |
Volume: | ±0,2 % of reading ±zero point stability |
Sensor |
Instrisically safe sensor circuits |
DMT 01 ATEX E 149 X |
II 1/2 G Ex ia IIC T6 – T2 |
(Zone 0 is permitted in the measuring tube) |
NEPSI Approval Cert. No. GYJ06476X |
GOST-R |
UMC-3 |
BVS 05 ATEX E 021 X |
II (1)2G EEx de [ia] IIC/IIB T6–T3 |
II (1)2G EEx d [ia] IIC/IIB T6–T3 |
NEPSI Approval Cert. No. GYJ06477 |
GOST-R |
UMC-4 |
BVS 10 ATEX E 110 X |
II (1)2G Ex d [ia Ga] IIC T4–T3 Gb |
IEC-Ex |
WJF Instrumentation Ltd.
#5 3610 – 29th Street N.E.
Calgary, Alberta
Canada
T1Y 5Z7
Calgary Head Office
Toll-Free: (877)291-5572
Standard: (403)291-5570
Ontario & Maritimes Sales:
(905)809-6918