Surface Mount Temperature Sensor | RTD Temperature Transmitter.

MIST M340 RTD Temperature Transmitter Surface Mount Ring

Surface mount ring type RTD, extension cable to remote transmitter and M12 connector. Designed for heavy duty BTU temperature measurement applications

Surface Mount Temperature Sensor

The MIST M340 Surface Mount Temperature Sensor RTD Transmitter consists of surface mount ring type RTD, extension cable to remote transmitter and M12 connector. It is designed for heavy duty BTU temperature measurement applications due to its very high accuracy. As all the other MIST Series transducers, it can be re-calibrated and re-scaled in the field.

  • Output signals: 4-20mA 2-wire; 0-5, 1-5, 0-10 VDC 3-wire.
  • Input: Platinum RTD 100, Class A, 3-wire.
  • Ranges: Std. and programmable from -50°C to 200°C.
  • Power Supply: 10-32 VDC polarity protected.
  • Accuracy: ±(.10°C + 0.10% of calibrated span ) with two-point calibration.
  • Wetted Mat’l: SS316/316L, dual certified.
  • Housing: Mat’l: SS316.
  • Electrical Connection: M12 male receptacle Operating Temp. Range: -40°C to 80°C (housing only).
  • Protection: Meets NEMA 6P, IP67 (IEC 529).
00 Surface Mount Temperature
01 Surface Mount Temperature
02 Surface Mount Temperature
Surface Mount Temperature
Surface Mount Temperature 5 & 6
Surface Mount Temperature 8 & 9
Surface Mount Temperature 10

Electrical Properties

Input RTD, type Pt100
Sensor Temperature Ranges See Box1 code for standard ranges. Field re-scalable between -200 ºC to 600 ºC or -50 ºC to 200 ºC, depending on model.
Outputs 4-20 mA loop powered, 2-wire, linear to temperature 0-5 Vdc, 1-5 Vdc, 0-10 Vdc all 3-wire, linear to temperature
Minimum Input Impedance 1000 Ohm (of measuring device, for voltage output)
Power Supply 12-32 VDC, polarity protected
Supply Effect 0.001 % / V
Accuracy ± ( .25 ºC + 0.40 % of span ) with one-point calibration 1. ± ( .10 ºC + 0.10 % of calibrated span ) with two-point calibration 2.
Maximum Loop Resistance [ ( Vsupply – 7 ) * 40 ] ohms ( for 4-20 mA output only )
Sensor Open Circuit Upscale 24 mA or Downscale 2.5 mA ( for 4-20 mA output only )
Warmup 30 seconds
RFI Effect 1 % or less typical
Isolation 500 Vdc Input / Output
Temp. Effects ± 0.001 % of Span / ºC
Long Term Drift ≤ 0.1 % FS / Year

Mechanical Properties

Sanitary Series
Wetted Surface Material Stainless steel 316 / 316L, dual certified Environmental Rating
Head assemblies Refer to head enclosures specifications
Cabled probe and M12 connection Meets NEMA 6P ( IP67 ), hermetically sealed
Cable Material PVC, Teflon ®, SS armor over Teflon ®
Protection Meets NEMA 6P ( IP67 ), hermetically sealed
Storage Temp. Range -40 ºC to 80 ºC
Operating Temp. Range -40 ºC to 80 ºC ( housing only )
Maximum Operating Pressure 500 PSIG ( applies to sensor portion only )
Description

The MIST M340 Surface Mount Temperature Sensor RTD Transmitter consists of surface mount ring type RTD, extension cable to remote transmitter and M12 connector. It is designed for heavy duty BTU temperature measurement applications due to its very high accuracy. As all the other MIST Series transducers, it can be re-calibrated and re-scaled in the field.

  • Output signals: 4-20mA 2-wire; 0-5, 1-5, 0-10 VDC 3-wire.
  • Input: Platinum RTD 100, Class A, 3-wire.
  • Ranges: Std. and programmable from -50°C to 200°C.
  • Power Supply: 10-32 VDC polarity protected.
  • Accuracy: ±(.10°C + 0.10% of calibrated span ) with two-point calibration.
  • Wetted Mat’l: SS316/316L, dual certified.
  • Housing: Mat’l: SS316.
  • Electrical Connection: M12 male receptacle Operating Temp. Range: -40°C to 80°C (housing only).
  • Protection: Meets NEMA 6P, IP67 (IEC 529).
Options
00 Surface Mount Temperature
01 Surface Mount Temperature
02 Surface Mount Temperature
Surface Mount Temperature
Surface Mount Temperature 5 & 6
Surface Mount Temperature 8 & 9
Surface Mount Temperature 10
Specifications

Electrical Properties

Input RTD, type Pt100
Sensor Temperature Ranges See Box1 code for standard ranges. Field re-scalable between -200 ºC to 600 ºC or -50 ºC to 200 ºC, depending on model.
Outputs 4-20 mA loop powered, 2-wire, linear to temperature 0-5 Vdc, 1-5 Vdc, 0-10 Vdc all 3-wire, linear to temperature
Minimum Input Impedance 1000 Ohm (of measuring device, for voltage output)
Power Supply 12-32 VDC, polarity protected
Supply Effect 0.001 % / V
Accuracy ± ( .25 ºC + 0.40 % of span ) with one-point calibration 1. ± ( .10 ºC + 0.10 % of calibrated span ) with two-point calibration 2.
Maximum Loop Resistance [ ( Vsupply – 7 ) * 40 ] ohms ( for 4-20 mA output only )
Sensor Open Circuit Upscale 24 mA or Downscale 2.5 mA ( for 4-20 mA output only )
Warmup 30 seconds
RFI Effect 1 % or less typical
Isolation 500 Vdc Input / Output
Temp. Effects ± 0.001 % of Span / ºC
Long Term Drift ≤ 0.1 % FS / Year

Mechanical Properties

Sanitary Series
Wetted Surface Material Stainless steel 316 / 316L, dual certified Environmental Rating
Head assemblies Refer to head enclosures specifications
Cabled probe and M12 connection Meets NEMA 6P ( IP67 ), hermetically sealed
Cable Material PVC, Teflon ®, SS armor over Teflon ®
Protection Meets NEMA 6P ( IP67 ), hermetically sealed
Storage Temp. Range -40 ºC to 80 ºC
Operating Temp. Range -40 ºC to 80 ºC ( housing only )
Maximum Operating Pressure 500 PSIG ( applies to sensor portion only )