wjf-logo
1 877 291 5572    |    Contact Us    |    Search

Industrial Magnetic Flow Meter for Liquids, Pastes, and Slurries

EPS - Industrial Magnetic Flow Meter

Accurate, pressure-drop free, volumetric flow measurement of liquids, slurries, pastes, and other electrically conductive media.

Industrial Magnetic Flow Meter for Liquids, Pastes, and Slurries

DTG6 A LED Display, 24 VDC Source 3-wire Switch Output

  • High Accuracy: 0.3 % of Measured Value ± 0.01 % * (Q at 10 m/s) (Under Reference Conditions).
  • Maintenance-free.
  • No Pressure Drop.
  • Wide Variety of Lining and Electrode Materials.
  • Electrodes in Stainless Steel, Hastelloy® C276, Tantalum, Platinum-Iridium, Titanium.
  • Large Selection of Process Connections.
  • For Use in Harsh Environments.
 

The EPS Industrial Magnetic Flow Meter delivers accurate, pressure-drop free, volumetric flow measurement of liquids, slurries, pastes, and other electrically conductive media. The measurement is unaffected by pressure, temperature, density, or viscosity. The EPS sensor is paired with the UMF2 transmitter, which is available in a compact or a remote version.

The EPS offers several advantages over similar models. It is designed specifically for reliability and longevity in harsh environments, comes in a wide variety of lining materials to maximize compatibility with the process media, and offers a large selection of process connections. It also features electrodes in stainless steel, Hastelloy C276, tantalum, platinum-iridium, and titanium. Linings are available in hard rubber, soft rubber, EPDM, PTFE, and ceramic. With these features, the EPS is an ideal solution for a wide variety of liquids, pastes, and slurries.

We offer the MIS Industrial Magnetic Flow Meter for lines sizes from 2″ to 8″ and features an integral LCD touch display, bi-directional flow measurement, batching, totalizing, and IO-Link.

Pressure, temperature, density and viscosity do not affect the volume measurements. Solid particles and small gas bubbles should be avoided.

An electrically conductive media flowing through a magnetic field, in accordance to Faraday’s law of induction, will induce a voltage proportional to the mean flow velocity rate and hence the volumetric flow. A magnetic inductive flowmeter consists of a lined flow body, through which a conductive liquid flows, a magnetic field coil and two electrodes. The electrode voltage is detected by a transmitter and converted into standardized electrical signal such as 4-20 mA or pulse output.

See PDF Brochure for Options Here

EPS Sensor

Industrial Magnetic Flow Meter

UMF2 Transmitter

Technical Details for EPS Sensor

Flow Body: Painted Steel (Standard), Stainless Steel
Tri-Clamp®, Ceramic Models
Nominal Sizes: 1/12″ , 1/8″, 1/4″, 3/8″ Inside Diameter
Process Connection in ½” NPT,
ANSI ½” … 24″
(Other Nominal Sizes on Request)
Connection: Flanges of Steel or 304 Stainless Steel
(ASME B16.5), 1/2″ NPT of 316L
Stainless Steel or Hastelloy®, or
Tri-Clamp®
(Other Connections on Request)
Lining Material: Hard Rubber, Soft Rubber, EPDM, PTFE,
or Ceramic
Electrode Material: 316-Ti Stainless Steel, Hastelloy® C276,
Titanium, Tantalum or Platinum-Iridium
Straight Piping
Requirement: 5x Upstream, 2x Downstream
Nominal Pressure (ANSI Flange) per ASME B16.5:
(verify flange material, rating, & temperature)

1/2″ to 24″: Class 150, 230 PSI
1/2″ to 12″: Class 300, 580 PSI
(Higher Pressures on Request)
Process Temperature:
EPDM Lining: 14…158 °F
PTFE Lining: -4…302 °F
Ceramic Lining
w/ EPDM Gaskets: -4…302°F
w/ PTFE Gaskets: -4…266°F
Hard Rubber: 32…203 °F
Soft Rubber: 32…158 °F
Ambient Temp: -4…140 °F, Depending on Process
Temperature
Conductivity: ≥ 5 μS/cm
≥ 20 μS/cm with Demineralized Water
Measuring Ranges: 0.5 m/s … 10 m/s
Accuracy: ± 0.3 % of Measured Value
± 0.01 % * (Q at 10 m/s)
(Under Reference Conditions)
Repeatability: ± 0.15 % of Measured Value
± 0.005 % * (Q at 10 m/s)
(Under Reference Conditions)
Protection: IP67 (EN60529), IP68
 

Technical Details for UMF2 Transmitter

Mounting Options: Compact or Remote
Housing: Die Cast Aluminum, Painted
Power Supply: 115 / 230 VAC 50/60 Hz, 10 VA 24 VDC 10 W
Indication: LCD, 2-lines, 16 Digits, Back-lit
Interface Language: English, German
Output
Analog: 4-20 mA, Active, Galvanically Isolated
Pulse: Passive, Galvanically Isolated 24 V, 60 mA
Status: Passive, Galvanically Isolated 24 V, 60 mA
Ambient Temp: -4…140 °F (-20…60 °C), Depending on Process Temperature
Protection: IP67 or IP68 (EN60529)
Communication: HART®
Diagnostics: Empty Pipe Detection, Coil Current Monitoring
Electromagnetic
Tolerance: EMC-Directive 2014/30/EU (EMC)
Description
  • High Accuracy: 0.3 % of Measured Value ± 0.01 % * (Q at 10 m/s) (Under Reference Conditions).
  • Maintenance-free.
  • No Pressure Drop.
  • Wide Variety of Lining and Electrode Materials.
  • Electrodes in Stainless Steel, Hastelloy® C276, Tantalum, Platinum-Iridium, Titanium.
  • Large Selection of Process Connections.
  • For Use in Harsh Environments.
 

The EPS Industrial Magnetic Flow Meter delivers accurate, pressure-drop free, volumetric flow measurement of liquids, slurries, pastes, and other electrically conductive media. The measurement is unaffected by pressure, temperature, density, or viscosity. The EPS sensor is paired with the UMF2 transmitter, which is available in a compact or a remote version.

The EPS offers several advantages over similar models. It is designed specifically for reliability and longevity in harsh environments, comes in a wide variety of lining materials to maximize compatibility with the process media, and offers a large selection of process connections. It also features electrodes in stainless steel, Hastelloy C276, tantalum, platinum-iridium, and titanium. Linings are available in hard rubber, soft rubber, EPDM, PTFE, and ceramic. With these features, the EPS is an ideal solution for a wide variety of liquids, pastes, and slurries.

We offer the MIS Industrial Magnetic Flow Meter for lines sizes from 2″ to 8″ and features an integral LCD touch display, bi-directional flow measurement, batching, totalizing, and IO-Link.

Pressure, temperature, density and viscosity do not affect the volume measurements. Solid particles and small gas bubbles should be avoided.

An electrically conductive media flowing through a magnetic field, in accordance to Faraday’s law of induction, will induce a voltage proportional to the mean flow velocity rate and hence the volumetric flow. A magnetic inductive flowmeter consists of a lined flow body, through which a conductive liquid flows, a magnetic field coil and two electrodes. The electrode voltage is detected by a transmitter and converted into standardized electrical signal such as 4-20 mA or pulse output.

Options
See PDF Brochure for Options Here
Specifications

EPS Sensor

Industrial Magnetic Flow Meter

UMF2 Transmitter

Technical Details for EPS Sensor

Flow Body: Painted Steel (Standard), Stainless Steel
Tri-Clamp®, Ceramic Models
Nominal Sizes: 1/12″ , 1/8″, 1/4″, 3/8″ Inside Diameter
Process Connection in ½” NPT,
ANSI ½” … 24″
(Other Nominal Sizes on Request)
Connection: Flanges of Steel or 304 Stainless Steel
(ASME B16.5), 1/2″ NPT of 316L
Stainless Steel or Hastelloy®, or
Tri-Clamp®
(Other Connections on Request)
Lining Material: Hard Rubber, Soft Rubber, EPDM, PTFE,
or Ceramic
Electrode Material: 316-Ti Stainless Steel, Hastelloy® C276,
Titanium, Tantalum or Platinum-Iridium
Straight Piping
Requirement: 5x Upstream, 2x Downstream
Nominal Pressure (ANSI Flange) per ASME B16.5:
(verify flange material, rating, & temperature)

1/2″ to 24″: Class 150, 230 PSI
1/2″ to 12″: Class 300, 580 PSI
(Higher Pressures on Request)
Process Temperature:
EPDM Lining: 14…158 °F
PTFE Lining: -4…302 °F
Ceramic Lining
w/ EPDM Gaskets: -4…302°F
w/ PTFE Gaskets: -4…266°F
Hard Rubber: 32…203 °F
Soft Rubber: 32…158 °F
Ambient Temp: -4…140 °F, Depending on Process
Temperature
Conductivity: ≥ 5 μS/cm
≥ 20 μS/cm with Demineralized Water
Measuring Ranges: 0.5 m/s … 10 m/s
Accuracy: ± 0.3 % of Measured Value
± 0.01 % * (Q at 10 m/s)
(Under Reference Conditions)
Repeatability: ± 0.15 % of Measured Value
± 0.005 % * (Q at 10 m/s)
(Under Reference Conditions)
Protection: IP67 (EN60529), IP68
 

Technical Details for UMF2 Transmitter

Mounting Options: Compact or Remote
Housing: Die Cast Aluminum, Painted
Power Supply: 115 / 230 VAC 50/60 Hz, 10 VA 24 VDC 10 W
Indication: LCD, 2-lines, 16 Digits, Back-lit
Interface Language: English, German
Output
Analog: 4-20 mA, Active, Galvanically Isolated
Pulse: Passive, Galvanically Isolated 24 V, 60 mA
Status: Passive, Galvanically Isolated 24 V, 60 mA
Ambient Temp: -4…140 °F (-20…60 °C), Depending on Process Temperature
Protection: IP67 or IP68 (EN60529)
Communication: HART®
Diagnostics: Empty Pipe Detection, Coil Current Monitoring
Electromagnetic
Tolerance: EMC-Directive 2014/30/EU (EMC)
Downloads