Home > Temperature > Industrial Magnetic Flow Meter
The EPS Industrial Magnetic Flow Meter delivers accurate, pressure-drop free, volumetric flow measurement of liquids, slurries, pastes, and other electrically conductive media. The measurement is unaffected by pressure, temperature, density, or viscosity. The EPS sensor is paired with the UMF2 transmitter, which is available in a compact or a remote version.
The EPS offers several advantages over similar models. It is designed specifically for reliability and longevity in harsh environments, comes in a wide variety of lining materials to maximize compatibility with the process media, and offers a large selection of process connections. It also features electrodes in stainless steel, Hastelloy C276, tantalum, platinum-iridium, and titanium. Linings are available in hard rubber, soft rubber, EPDM, PTFE, and ceramic. With these features, the EPS is an ideal solution for a wide variety of liquids, pastes, and slurries.
We offer the MIS Industrial Magnetic Flow Meter for lines sizes from 2″ to 8″ and features an integral LCD touch display, bi-directional flow measurement, batching, totalizing, and IO-Link.
Pressure, temperature, density and viscosity do not affect the volume measurements. Solid particles and small gas bubbles should be avoided.
An electrically conductive media flowing through a magnetic field, in accordance to Faraday’s law of induction, will induce a voltage proportional to the mean flow velocity rate and hence the volumetric flow. A magnetic inductive flowmeter consists of a lined flow body, through which a conductive liquid flows, a magnetic field coil and two electrodes. The electrode voltage is detected by a transmitter and converted into standardized electrical signal such as 4-20 mA or pulse output.
Flow Body: | Painted Steel (Standard), Stainless Steel Tri-Clamp®, Ceramic Models |
Nominal Sizes: | 1/12″ , 1/8″, 1/4″, 3/8″ Inside Diameter Process Connection in ½” NPT, ANSI ½” … 24″ (Other Nominal Sizes on Request) |
Connection: | Flanges of Steel or 304 Stainless Steel (ASME B16.5), 1/2″ NPT of 316L Stainless Steel or Hastelloy®, or Tri-Clamp® (Other Connections on Request) |
Lining Material: | Hard Rubber, Soft Rubber, EPDM, PTFE, or Ceramic |
Electrode Material: | 316-Ti Stainless Steel, Hastelloy® C276, Titanium, Tantalum or Platinum-Iridium |
Straight Piping | |
Requirement: | 5x Upstream, 2x Downstream |
Nominal Pressure (ANSI Flange) per ASME B16.5: (verify flange material, rating, & temperature) | |
1/2″ to 24″: | Class 150, 230 PSI |
1/2″ to 12″: | Class 300, 580 PSI (Higher Pressures on Request) |
Process Temperature: | |
EPDM Lining: | 14…158 °F |
PTFE Lining: | -4…302 °F |
Ceramic Lining | |
w/ EPDM Gaskets: | -4…302°F |
w/ PTFE Gaskets: | -4…266°F |
Hard Rubber: | 32…203 °F |
Soft Rubber: | 32…158 °F |
Ambient Temp: | -4…140 °F, Depending on Process Temperature |
Conductivity: | ≥ 5 μS/cm ≥ 20 μS/cm with Demineralized Water |
Measuring Ranges: | 0.5 m/s … 10 m/s |
Accuracy: | ± 0.3 % of Measured Value ± 0.01 % * (Q at 10 m/s) (Under Reference Conditions) |
Repeatability: | ± 0.15 % of Measured Value ± 0.005 % * (Q at 10 m/s) (Under Reference Conditions) |
Protection: | IP67 (EN60529), IP68 |
Mounting Options: | Compact or Remote |
Housing: | Die Cast Aluminum, Painted |
Power Supply: | 115 / 230 VAC 50/60 Hz, 10 VA 24 VDC 10 W |
Indication: | LCD, 2-lines, 16 Digits, Back-lit |
Interface Language: | English, German |
Output | |
Analog: | 4-20 mA, Active, Galvanically Isolated |
Pulse: | Passive, Galvanically Isolated 24 V, 60 mA |
Status: | Passive, Galvanically Isolated 24 V, 60 mA |
Ambient Temp: | -4…140 °F (-20…60 °C), Depending on Process Temperature |
Protection: | IP67 or IP68 (EN60529) |
Communication: | HART® |
Diagnostics: | Empty Pipe Detection, Coil Current Monitoring |
Electromagnetic | |
Tolerance: | EMC-Directive 2014/30/EU (EMC) |
The EPS Industrial Magnetic Flow Meter delivers accurate, pressure-drop free, volumetric flow measurement of liquids, slurries, pastes, and other electrically conductive media. The measurement is unaffected by pressure, temperature, density, or viscosity. The EPS sensor is paired with the UMF2 transmitter, which is available in a compact or a remote version.
The EPS offers several advantages over similar models. It is designed specifically for reliability and longevity in harsh environments, comes in a wide variety of lining materials to maximize compatibility with the process media, and offers a large selection of process connections. It also features electrodes in stainless steel, Hastelloy C276, tantalum, platinum-iridium, and titanium. Linings are available in hard rubber, soft rubber, EPDM, PTFE, and ceramic. With these features, the EPS is an ideal solution for a wide variety of liquids, pastes, and slurries.
We offer the MIS Industrial Magnetic Flow Meter for lines sizes from 2″ to 8″ and features an integral LCD touch display, bi-directional flow measurement, batching, totalizing, and IO-Link.
Pressure, temperature, density and viscosity do not affect the volume measurements. Solid particles and small gas bubbles should be avoided.
An electrically conductive media flowing through a magnetic field, in accordance to Faraday’s law of induction, will induce a voltage proportional to the mean flow velocity rate and hence the volumetric flow. A magnetic inductive flowmeter consists of a lined flow body, through which a conductive liquid flows, a magnetic field coil and two electrodes. The electrode voltage is detected by a transmitter and converted into standardized electrical signal such as 4-20 mA or pulse output.
Flow Body: | Painted Steel (Standard), Stainless Steel Tri-Clamp®, Ceramic Models |
Nominal Sizes: | 1/12″ , 1/8″, 1/4″, 3/8″ Inside Diameter Process Connection in ½” NPT, ANSI ½” … 24″ (Other Nominal Sizes on Request) |
Connection: | Flanges of Steel or 304 Stainless Steel (ASME B16.5), 1/2″ NPT of 316L Stainless Steel or Hastelloy®, or Tri-Clamp® (Other Connections on Request) |
Lining Material: | Hard Rubber, Soft Rubber, EPDM, PTFE, or Ceramic |
Electrode Material: | 316-Ti Stainless Steel, Hastelloy® C276, Titanium, Tantalum or Platinum-Iridium |
Straight Piping | |
Requirement: | 5x Upstream, 2x Downstream |
Nominal Pressure (ANSI Flange) per ASME B16.5: (verify flange material, rating, & temperature) | |
1/2″ to 24″: | Class 150, 230 PSI |
1/2″ to 12″: | Class 300, 580 PSI (Higher Pressures on Request) |
Process Temperature: | |
EPDM Lining: | 14…158 °F |
PTFE Lining: | -4…302 °F |
Ceramic Lining | |
w/ EPDM Gaskets: | -4…302°F |
w/ PTFE Gaskets: | -4…266°F |
Hard Rubber: | 32…203 °F |
Soft Rubber: | 32…158 °F |
Ambient Temp: | -4…140 °F, Depending on Process Temperature |
Conductivity: | ≥ 5 μS/cm ≥ 20 μS/cm with Demineralized Water |
Measuring Ranges: | 0.5 m/s … 10 m/s |
Accuracy: | ± 0.3 % of Measured Value ± 0.01 % * (Q at 10 m/s) (Under Reference Conditions) |
Repeatability: | ± 0.15 % of Measured Value ± 0.005 % * (Q at 10 m/s) (Under Reference Conditions) |
Protection: | IP67 (EN60529), IP68 |
Mounting Options: | Compact or Remote |
Housing: | Die Cast Aluminum, Painted |
Power Supply: | 115 / 230 VAC 50/60 Hz, 10 VA 24 VDC 10 W |
Indication: | LCD, 2-lines, 16 Digits, Back-lit |
Interface Language: | English, German |
Output | |
Analog: | 4-20 mA, Active, Galvanically Isolated |
Pulse: | Passive, Galvanically Isolated 24 V, 60 mA |
Status: | Passive, Galvanically Isolated 24 V, 60 mA |
Ambient Temp: | -4…140 °F (-20…60 °C), Depending on Process Temperature |
Protection: | IP67 or IP68 (EN60529) |
Communication: | HART® |
Diagnostics: | Empty Pipe Detection, Coil Current Monitoring |
Electromagnetic | |
Tolerance: | EMC-Directive 2014/30/EU (EMC) |
WJF Instrumentation Ltd.
#5 3610 – 29th Street N.E.
Calgary, Alberta
Canada
T1Y 5Z7
Calgary Head Office
Toll-Free: (877)291-5572
Standard: (403)291-5570