Physical
|
| Dimensions (hxwxd) |
470 x Ø80 mm |
| Weight |
2.2 kg (inc 10 metres of cable) |
| Protection Class |
IP68 |
| Enclosure Material |
Black Acetal Co-polymer |
| Cable Entries |
Integral Cable Gland |
| Wetted Parts |
Black Acetal, 316 Stainless Steel, Glass, Polyurethane, Nitrile |
| Cable Type |
4 core, 2 Twisted Pair, 9 mm O/D Polyurethane Coated |
| Cable Length |
10 metres standard, 100 metres maximum |
| Service Requirement |
Automatic Self Cleaning Seal Service every 3500 cleans (application dependent) |
Environmental Data
|
|
| Operating Temperature |
0 to 50ºC |
| Interface to Monitor |
| Power Supply |
12 VDC from Monitor |
| Sensor Output |
ModTechw², RS485 |
Measurement Characteristics
|
| Range |
0 – 50,000 mg/l |
| Accuracy |
±5% of reading or 100 mg/l whichever is greater |
| Limit of Detection |
250 mg/l |
| Minimum Operating Range |
0 – 5,000 mg/l |
| Measurement Principle |
Light Attenuation |
| Wavelength |
860 nm Infrared |
| Pressure Rating (Depth) |
1Bar or 14.5 psi |
| Flowrate |
Not affected by flowrate, avoid deadspots and extreme turbulence |
| Units |
FAU, mg/l, ppm, g/l, %SS, User Defined |
| |
NOTE: The actual measuring range for Suspended Solids will depend on the nature of sample being monitored and cannot be guaranteed. |