DTG07 Digital Temperature Gauge

Back Mount RTD sensor probe with Compression Fitting

Back Mount Digital Temperature Gauge and RTD Sensor Probe, Compression Mount
  • Description
  • Options
  • Specification
  • Downloads

The DTG07 series Digital Temperature Gauges are a complete solution for most industrial temperature monitoring and temperature indicating applications.

Of high quality construction, these gauges features a bright and large 4-digit red LED display with an analog 4-20 mA output.

Based on Intempco’s patented MIST™ technology, they are designed for optimum accuracy and performance.

The series DTG07 are an ideal replacement for bi-metal, liquid bulb and gas thermometers.

The DTG07s can be factory calibrated to customer specified temperature range. As with any other MIST™ series patented technology sensor, the DTG’s built-in programmable transmitter can be re-scaled and re-calibrated using the optional interface module and software.

The DTG arrives factory scaled and calibrated to the customer’s specified temperature range. No costly field calibration is required. If the application changes, the DTG can be re-scaled at any range within the sensor limits while maintaining its accuracy. Reprogramming is done with the optional PC interface module and software.

Housing, probe and fitting material is all fabricated from Stainless Steel 316. DTG is rated to NEMA 4X ( IP65 ).

Many mounting configurations are available to meet customer requirements. Standard extension cables offered are PVC or Silicon insulated wires. Some models are available with M12 Micro-Male Connector.

Certain features of this product are covered under US Patent no.: 7,233,014

  • Large 4-digit red LED display.
  • Field re-programmable with optional PC software.
  • Security protection.
  • 4-20 mA programmable linearized signal output.
  • Utilizes self-calibration feature for accurate and stable performance.
  • Utilizes Pt-100 Ohm RTD Class A element.
  • M12 male plug or cable for electrical connection.
  • IP 65 / NEMA 4 rated environmental protection.
  • All stainless 316 construction.
  • Easy installation with various mounting configurations.

Custom Builder

Sensing Element RTD, Type Pt100 Class A
Temperature Ranges Customer re-scalable between –200 o C to 600 o C or –50 o C to 200 o C depending model. No re-calibration required.
Switching Ranges Customer programmable between –200 o C to 600 o C or –50 o C to 200 o C depending model.
Hysteresis Customer programmable, 1% of range by factory setting.
Accuracy ± ( 0.25 o C + 0.40 % of reading ) max. with default calibration. ± ( 0.10 o C + 0.20 % of reading ) max. with one-point factory or customer calibration.
Open circuit detection Upscale ( 22 mA ) or Downscale ( 2.5 mA ) current output. Error message on LED display.
Warm-up 30 seconds.
Response Time 0.5 sec to 30 sec ( software selectable )
Display 4-DIGITS LED, decimal point selectable by software.
Display resolution ± 0.02 % F.S. ±1 DIGIT
RFI effect 1 % or less typical
Temp. Effect < 0.01 % FS/ o C
Ambient Temp. Range – 40 o C to 80 o C ( -40 o F to 176 o F )
Storage Temp. Range – 50 o C to 85 o C ( -58 o F to 185 o F )
Max. Pressure 500 PSIG ( on probe )
Housing Material Stainless steel 316
Probe Material Stainless steel 316 standard
Cable Materials PVC, Teflon®, Silicone, SS armored Teflon®
Environmental Protection NEMA 4/IP 65
ELE CTRICAL
Power Supply 9-36 VDC, polarity protected
Supply effect 0.005 %/V
Power consumption 15 mA @ 24 VDC + output current – 950 mW max. 20 mA @ 24 VDC for PNP output – 500 mW max. 20 mA @ 24 VDC + sourcing current for NPN output 50 mA @ 24 VDC for Relay Output – 1200 mW max.
Current Output4-20 mA (3 wires configuration) linear to temperature.
Max load on current output ( Vsupply-9V )/ 20 mA, Ohms
Switching Output Transistor NPN ( max 100 mA source ) or Transistor PNP (max 100mA sink) or Relay SPDT 0.5A @ 240 VAC
Switching Logic N.C. or N.O. Software selectable.
Isolation 500 VDC Input / Output ( between probe and output signal )
Electrical Connection Micro-DC male plug or cable only

Teflon ® is a registered trademark of E.I. du Pont de Nemours and Company.
1. Max. error on complete span. Error at calibration point ≤ 0.1 % of Span.
2. Max. error on complete calibrated span. Error at calibration points ≤ 0.1 % of Span.
3. Intempco sanitary sensors bearing the 3-A symbol meet the requirements of 3-A Sanitary Standards for Sensors and Sensor Fittings and Connections,
Number 74-03, with some exceptions to section D10 for heat sterilization systems . Intempco sensors meet the requirements of section D10.1 and D10.1.1
for sterilization of the product contact surfaces, with exception made for section D10.1.2 and D10.1.3. Intempco sensors do not have a steam or other
sterilization chamber surrounding the joint at the product contact surfaces between the fitting and the devices.
• Information furnished by Intempco is believed to be accurate and reliable. However, no responsibility is assumed by Intempco for its use.
• Specifications subject to change without notice

The DTG07 series Digital Temperature Gauges are a complete solution for most industrial temperature monitoring and temperature indicating applications.

Of high quality construction, these gauges features a bright and large 4-digit red LED display with an analog 4-20 mA output.

Based on Intempco’s patented MIST™ technology, they are designed for optimum accuracy and performance.

The series DTG07 are an ideal replacement for bi-metal, liquid bulb and gas thermometers.

The DTG07s can be factory calibrated to customer specified temperature range. As with any other MIST™ series patented technology sensor, the DTG’s built-in programmable transmitter can be re-scaled and re-calibrated using the optional interface module and software.

The DTG arrives factory scaled and calibrated to the customer’s specified temperature range. No costly field calibration is required. If the application changes, the DTG can be re-scaled at any range within the sensor limits while maintaining its accuracy. Reprogramming is done with the optional PC interface module and software.

Housing, probe and fitting material is all fabricated from Stainless Steel 316. DTG is rated to NEMA 4X ( IP65 ).

Many mounting configurations are available to meet customer requirements. Standard extension cables offered are PVC or Silicon insulated wires. Some models are available with M12 Micro-Male Connector.

Certain features of this product are covered under US Patent no.: 7,233,014

  • Large 4-digit red LED display.
  • Field re-programmable with optional PC software.
  • Security protection.
  • 4-20 mA programmable linearized signal output.
  • Utilizes self-calibration feature for accurate and stable performance.
  • Utilizes Pt-100 Ohm RTD Class A element.
  • M12 male plug or cable for electrical connection.
  • IP 65 / NEMA 4 rated environmental protection.
  • All stainless 316 construction.
  • Easy installation with various mounting configurations.

Custom Builder

Sensing Element RTD, Type Pt100 Class A
Temperature Ranges Customer re-scalable between –200 o C to 600 o C or –50 o C to 200 o C depending model. No re-calibration required.
Switching Ranges Customer programmable between –200 o C to 600 o C or –50 o C to 200 o C depending model.
Hysteresis Customer programmable, 1% of range by factory setting.
Accuracy ± ( 0.25 o C + 0.40 % of reading ) max. with default calibration. ± ( 0.10 o C + 0.20 % of reading ) max. with one-point factory or customer calibration.
Open circuit detection Upscale ( 22 mA ) or Downscale ( 2.5 mA ) current output. Error message on LED display.
Warm-up 30 seconds.
Response Time 0.5 sec to 30 sec ( software selectable )
Display 4-DIGITS LED, decimal point selectable by software.
Display resolution ± 0.02 % F.S. ±1 DIGIT
RFI effect 1 % or less typical
Temp. Effect < 0.01 % FS/ o C
Ambient Temp. Range – 40 o C to 80 o C ( -40 o F to 176 o F )
Storage Temp. Range – 50 o C to 85 o C ( -58 o F to 185 o F )
Max. Pressure 500 PSIG ( on probe )
Housing Material Stainless steel 316
Probe Material Stainless steel 316 standard
Cable Materials PVC, Teflon®, Silicone, SS armored Teflon®
Environmental Protection NEMA 4/IP 65
ELE CTRICAL
Power Supply 9-36 VDC, polarity protected
Supply effect 0.005 %/V
Power consumption 15 mA @ 24 VDC + output current – 950 mW max. 20 mA @ 24 VDC for PNP output – 500 mW max. 20 mA @ 24 VDC + sourcing current for NPN output 50 mA @ 24 VDC for Relay Output – 1200 mW max.
Current Output4-20 mA (3 wires configuration) linear to temperature.
Max load on current output ( Vsupply-9V )/ 20 mA, Ohms
Switching Output Transistor NPN ( max 100 mA source ) or Transistor PNP (max 100mA sink) or Relay SPDT 0.5A @ 240 VAC
Switching Logic N.C. or N.O. Software selectable.
Isolation 500 VDC Input / Output ( between probe and output signal )
Electrical Connection Micro-DC male plug or cable only

Teflon ® is a registered trademark of E.I. du Pont de Nemours and Company.
1. Max. error on complete span. Error at calibration point ≤ 0.1 % of Span.
2. Max. error on complete calibrated span. Error at calibration points ≤ 0.1 % of Span.
3. Intempco sanitary sensors bearing the 3-A symbol meet the requirements of 3-A Sanitary Standards for Sensors and Sensor Fittings and Connections,
Number 74-03, with some exceptions to section D10 for heat sterilization systems . Intempco sensors meet the requirements of section D10.1 and D10.1.1
for sterilization of the product contact surfaces, with exception made for section D10.1.2 and D10.1.3. Intempco sensors do not have a steam or other
sterilization chamber surrounding the joint at the product contact surfaces between the fitting and the devices.
• Information furnished by Intempco is believed to be accurate and reliable. However, no responsibility is assumed by Intempco for its use.
• Specifications subject to change without notice