Spec | Value |
---|---|
Product Properties & Material | |
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 5. |
Body | Brass (Body C with stainless steel seat 1.4112, except NBR version) or stainless steel 1.4581 |
Seal | NBR, FKM, others on request |
Solenoid Valve Performance data | |
KV value water | Measured at + 20 °C, 1 bar pressure at valve inlet and free outlet |
Response times | Opening Pressure build-up 0 to 90 % Closing Pressure decay 100 to 10 % |
Electrical Data | |
Voltage tolerance | ± 10 % |
Duty cycle | 100 % continuous rating |
Medium Data | |
NBR (EPDM on request) | Neutral media, compressed air, water, oil – 10 °C…+ 80 °C |
FKM | Hot air, hot oils, oils with additives – 10 °C…+ 130 °C |
Viscosity | Max. 21 mm2/s |
Process/Port connection & communication | |
Electrical connection | Cable plug for Ø 7 mm cable (supplied as standard) 2.) |
Environment and installation | |
Installation | As required, preferably with actuator upright |
Degree of protection | IP65 with cable plug |
Ambient temperature | Max. + 55 °C |
Explosion-proof approvals | |
ATEX: EPS 18 ATEX 1232 X II 2G Ex mb IIC T4 Gb II 2D Ex mb IIIC T130 ºC Db II 2G Ex eb mb IIC T4 Gb II 2D Ex mb tb IIIC T130 ºC Db | IECEx: IECEx EPS 18.0110 X Ex mb IIC T4 Gb Ex mb IIIC T130 ºC Db Ex eb mb IIC T4 Gb Ex mb tb IIIC T130 ºC Db |
Approved for Hazardous Locations. CSA, Class 1, Div. 1. Class 1 Div. 2, Groups A,B,C and D. Zone 0, Zone 1 and zone 2. |
Full details can be found in the 0256 Data Sheet
Spec | Value |
---|---|
Product Properties & Material | |
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 5. |
Body | Brass (Body C with stainless steel seat 1.4112, except NBR version) or stainless steel 1.4581 |
Seal | NBR, FKM, others on request |
Solenoid Valve Performance data | |
KV value water | Measured at + 20 °C, 1 bar pressure at valve inlet and free outlet |
Response times | Opening Pressure build-up 0 to 90 % Closing Pressure decay 100 to 10 % |
Electrical Data | |
Voltage tolerance | ± 10 % |
Duty cycle | 100 % continuous rating |
Medium Data | |
NBR (EPDM on request) | Neutral media, compressed air, water, oil – 10 °C…+ 80 °C |
FKM | Hot air, hot oils, oils with additives – 10 °C…+ 130 °C |
Viscosity | Max. 21 mm2/s |
Process/Port connection & communication | |
Electrical connection | Cable plug for Ø 7 mm cable (supplied as standard) 2.) |
Environment and installation | |
Installation | As required, preferably with actuator upright |
Degree of protection | IP65 with cable plug |
Ambient temperature | Max. + 55 °C |
Explosion-proof approvals | |
ATEX: EPS 18 ATEX 1232 X II 2G Ex mb IIC T4 Gb II 2D Ex mb IIIC T130 ºC Db II 2G Ex eb mb IIC T4 Gb II 2D Ex mb tb IIIC T130 ºC Db | IECEx: IECEx EPS 18.0110 X Ex mb IIC T4 Gb Ex mb IIIC T130 ºC Db Ex eb mb IIC T4 Gb Ex mb tb IIIC T130 ºC Db |
Approved for Hazardous Locations. CSA, Class 1, Div. 1. Class 1 Div. 2, Groups A,B,C and D. Zone 0, Zone 1 and zone 2. |