Home > Flowmeters > Paddle Wheel Flowmeters > Batch Controller Flowmeter
- Description
- Specification
- Controller Batch System
- Downloads
The Type 8025 batch controller flowmeter or batch controller is specially designed for use in neutral, slightly aggressive, solid-free liquids. Type 8025 flowmeter is offered in different versions.
The compact flowmeter with paddle wheel sensor is available in two versions:
- standard signal output or
- battery powered indicator/totalizer version without output.
The remote transmitter is available in two versions:
- Universal transmitter for control cabinet or wall mounting, which can be connected to other flow sensors; sensors with open collector output, reed relay output, TTL, CMOS or coil can be operated by this transmitter.
- Transmitter, for control cabinet or wall mounting: standard signal input for combination with the Bürkert Type 8020/8030/SE30+S077 flowmeters “Low Power” version.
Type 8025 batch controller is also available in various versions:
- The compact batch controller with paddle wheel sensor
- The remote batch controller for control cabinet or wall mounting for coupling to the Bürkert Type 8020/8030/8031/8041/SE30+S077 flowmeters or to other flow sensors; sensors with open collector output, reed relay output, TTL, CMOS or coil can be operated by this batch controller.
Featuring:
- Up to PN10, size of measuring tube: DN 06…DN 400
- Display for indication of flow rate and volume with two totalizers or dosing
- Automatic calibration using Teach-In
- Inputs (with batch controller) and all outputs can be checked without the need for actual flow
- Total and day counters for batch quantity and number of dosing, volume or mass counter indicator (with batch controller)
Insertion Flowmeter Specifications
Spec | Value |
---|---|
Non wetted parts |
|
Housing cover | PC |
Lid | PC |
Front Panel foil | Polyester |
Nutl | PC |
Seals | NBR |
Screws | Stainless steel |
Female cable plug/male fixed plug or cable glands | PA |
Wetted parts |
|
Seal | FKM standard (EPDM included, but not mounted) |
Axis and bearings | Ceramics (Al2O3) |
Sensor holder, paddle wheel | PVDF |
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 18 |
Measuring principle | Paddle wheel |
Compatibility | Any pipe from DN 20.)…DN 400 which is fitted with Bürkert S020 Insertion fitting. For the selection of the nominal diameter of the Insertion fittings, see data sheet Type S020 |
Display | 15 × 60 mm, 8-digit LCD, alphanumeric,15 segments, 9 mm high |
Pipe diameter | DN 20…DN 400 |
Measuring range |
|
Insertion Flowmeter Performance data |
|
Measurement deviation | Teach-In: ± 1 % of the measured value.) (at Teach-In flow rate value) Standard K-factor: ± 2.5 % of the measured value.) |
Linearity | ± 0.5 % of full scale |
Repeatability | ± 0.4 % of the measured value |
Electrical Data |
|
Power source (not supplied) | Limited power source according to UL/EN 60950-1 standards or limited energy circuit according to UL/EN 61010-1 §9.4 |
DC reverse polarity protection | Yes |
Overvoltage protection | Yes |
Voltage supply cable |
|
Full details can be found in the 8020 Data Sheet
Single or Multi 8025 Batch Controller flowmeter System
- Batched volume and totalizers displayed.
- Simulation: all output signals provided without need
of real flow. - Seven selectable preset programs.
- Automatic calibration: Teach-In.
- Customisation available on request.
- Enclosures available in mild and stainless steel and plastic/GRP
- Full set of drawings and tags.
- Installation and commissioning available upon request
The batch controller flowmeter is specially designed for use in neutral and slightly aggressive, solid-free liquids.
- Local dosing:
The user enters the quantity to be metered and initiates the dosage from the keypad. - Local dosing with pre-set quantity: The user selects a quantity which has been preset and initiates the dosage from the keypad.
- Remote control dosing:
Using a rotary knob (selecting a pre-set quantity) or binary data inputs. - Dosing controlled by a PLC unit: Using binary data inputs.
- Automatic dosing controlled by variation of pulse duration.
The quantity of the dose is directly proportional to the duration of a pulse
Indication in operating mode / Display
- Dosing amount
- Dosing mode
- Main totalizer
- Daily totalizer with reset function Parameter definition
- Language
- Engineering units
- K-factor / TEACH-IN function
- Selection of dosing mode
- Over-run correction
- Alarm
- Function mode of relays
- Reset main totalizer Test
- Display of state of binary inputs
- Relay test
- Frequency test
The Type 8025 batch controller flowmeter or batch controller is specially designed for use in neutral, slightly aggressive, solid-free liquids. Type 8025 flowmeter is offered in different versions.
The compact flowmeter with paddle wheel sensor is available in two versions:
- standard signal output or
- battery powered indicator/totalizer version without output.
The remote transmitter is available in two versions:
- Universal transmitter for control cabinet or wall mounting, which can be connected to other flow sensors; sensors with open collector output, reed relay output, TTL, CMOS or coil can be operated by this transmitter.
- Transmitter, for control cabinet or wall mounting: standard signal input for combination with the Bürkert Type 8020/8030/SE30+S077 flowmeters “Low Power” version.
Type 8025 batch controller is also available in various versions:
- The compact batch controller with paddle wheel sensor
- The remote batch controller for control cabinet or wall mounting for coupling to the Bürkert Type 8020/8030/8031/8041/SE30+S077 flowmeters or to other flow sensors; sensors with open collector output, reed relay output, TTL, CMOS or coil can be operated by this batch controller.
Featuring:
- Up to PN10, size of measuring tube: DN 06…DN 400
- Display for indication of flow rate and volume with two totalizers or dosing
- Automatic calibration using Teach-In
- Inputs (with batch controller) and all outputs can be checked without the need for actual flow
- Total and day counters for batch quantity and number of dosing, volume or mass counter indicator (with batch controller)
Insertion Flowmeter Specifications
Spec | Value |
---|---|
Non wetted parts |
|
Housing cover | PC |
Lid | PC |
Front Panel foil | Polyester |
Nutl | PC |
Seals | NBR |
Screws | Stainless steel |
Female cable plug/male fixed plug or cable glands | PA |
Wetted parts |
|
Seal | FKM standard (EPDM included, but not mounted) |
Axis and bearings | Ceramics (Al2O3) |
Sensor holder, paddle wheel | PVDF |
Dimensions | Detailed information can be found in chapter “4. Dimensions” on page 18 |
Measuring principle | Paddle wheel |
Compatibility | Any pipe from DN 20.)…DN 400 which is fitted with Bürkert S020 Insertion fitting. For the selection of the nominal diameter of the Insertion fittings, see data sheet Type S020 |
Display | 15 × 60 mm, 8-digit LCD, alphanumeric,15 segments, 9 mm high |
Pipe diameter | DN 20…DN 400 |
Measuring range |
|
Insertion Flowmeter Performance data |
|
Measurement deviation | Teach-In: ± 1 % of the measured value.) (at Teach-In flow rate value) Standard K-factor: ± 2.5 % of the measured value.) |
Linearity | ± 0.5 % of full scale |
Repeatability | ± 0.4 % of the measured value |
Electrical Data |
|
Power source (not supplied) | Limited power source according to UL/EN 60950-1 standards or limited energy circuit according to UL/EN 61010-1 §9.4 |
DC reverse polarity protection | Yes |
Overvoltage protection | Yes |
Voltage supply cable |
|
Full details can be found in the 8020 Data Sheet
Single or Multi 8025 Batch Controller flowmeter System
- Batched volume and totalizers displayed.
- Simulation: all output signals provided without need
of real flow. - Seven selectable preset programs.
- Automatic calibration: Teach-In.
- Customisation available on request.
- Enclosures available in mild and stainless steel and plastic/GRP
- Full set of drawings and tags.
- Installation and commissioning available upon request
The batch controller flowmeter is specially designed for use in neutral and slightly aggressive, solid-free liquids.
- Local dosing:
The user enters the quantity to be metered and initiates the dosage from the keypad. - Local dosing with pre-set quantity: The user selects a quantity which has been preset and initiates the dosage from the keypad.
- Remote control dosing:
Using a rotary knob (selecting a pre-set quantity) or binary data inputs. - Dosing controlled by a PLC unit: Using binary data inputs.
- Automatic dosing controlled by variation of pulse duration.
The quantity of the dose is directly proportional to the duration of a pulse
Indication in operating mode / Display
- Dosing amount
- Dosing mode
- Main totalizer
- Daily totalizer with reset function Parameter definition
- Language
- Engineering units
- K-factor / TEACH-IN function
- Selection of dosing mode
- Over-run correction
- Alarm
- Function mode of relays
- Reset main totalizer Test
- Display of state of binary inputs
- Relay test