wjf-logo
1 877 291 5572    |    Contact Us    |    Search

Specific Conductivity, Concentration of CIP Solutions, Salinity and TDS

Swan AMU Solicon 4

Control panel mountable transmitter for continuous measurement in surface water, potable water and cooling water.

continuous measurements of specific conductivity, concentration of CIP solutions, salinity and TDS in surface water, potable water and cooling water.
  • Description
  • Specification
  • Options
  • Downloads

An electronic transmitter for continuous measurements of specific conductivity, concentration of CIP solutions, salinity and TDS in surface water, potable water and cooling water. The size of the transmitter complies with DIN 43700 which allows it to be mounted in control panels easily. The transmitter case is produced from Noryl® resin and its front panel has a protection degree conformed IP54.

  • Four-electrode conductivity sensor with built-in Pt1000 temperature probe.
  • With selectable coefficient or nonlinear function for natural waters according to EN 27888/DIN 38404.
  • Conductivity
    0.055 μS/cm to 100 mS/cm

Swan instruments are delivered as fully functional, ready-to-use instruments. This ensures easy system integration as well as user-friendly operation and maintainability. Each analyzer is thoroughly tested and factory calibrated prior to delivery. With its uniform menu navigation for simple operation and maintenance – one platform for all instruments. The self-explanatory maintenance procedures can be easily performed by the operating company.

Shurecon P
Shurecon P ± 1.5 % or ± 0.2 μS/cm - Sample temperatures up to 90°C
Shurecon S
Shurecon P ± 1 % or ± 0.2 μS/cm - Sample temperatures up to 120°C

Specifications
Measuring and control transmitter for panel installation in a Noryl® resin enclosure (front IP 54).

Sensors:
Connections for a four-electrode conductivity sensor with built-in Pt1000 temperature sensor like Swansensor Shurecon P or Shurecon S and for a digital sample flow meter.

Measuring range:
0.05 μS/cm to 100 mS/cm
Conversion to concentration selectable for aqueous solutions of many chemicals.

User interface:

  • Big backlit LC display for measuring value, sample temperature, sample flow and operating status.
  • Easy user menus in English, German, French and Spanish.
  • Simple programming of all parameters by keypad.
  • Data logger for 1’500 data records stored at a selectable interval.

Connections:

  • 2 signal outputs (0/4 – 20 mA) for measured values or continuous control.
  • 2 potential-free contacts as limit switches or as controllers, configuration normally open.
  • 1 potential-free alarm contact as summary alarm indication, default configuration normally open (option: normally closed).
  • 1 input for potential-free contact for hold or remote-off function.
  • 1 serial interface RS232 for logger download.
  • Option: Profibus DP or Modbus RTU interface.
  • All in- and outputs protected against overvoltages.

Dimensions:

  • 96 x 96 x 120 mm (DIN 43700)
  • A-87.342.1X0 Swansensor Shurecon P, 1m
  • A-87.951.001 Separate Flowmeter, incl. Flowsensor; 1m
  • A-87.951.005 Separate Flowmeter, incl. Flowsensor; 5m
  • A-87.951.007 Separate Flowmeter, incl. Flowsensor; 15m
Shurecon P
Shurecon P ± 1.5 % or ± 0.2 μS/cm - Sample temperatures up to 90°C
Shurecon S
Shurecon P ± 1 % or ± 0.2 μS/cm - Sample temperatures up to 120°C

An electronic transmitter for continuous measurements of specific conductivity, concentration of CIP solutions, salinity and TDS in surface water, potable water and cooling water. The size of the transmitter complies with DIN 43700 which allows it to be mounted in control panels easily. The transmitter case is produced from Noryl® resin and its front panel has a protection degree conformed IP54.

  • Four-electrode conductivity sensor with built-in Pt1000 temperature probe.
  • With selectable coefficient or nonlinear function for natural waters according to EN 27888/DIN 38404.
  • Conductivity
    0.055 μS/cm to 100 mS/cm

Swan instruments are delivered as fully functional, ready-to-use instruments. This ensures easy system integration as well as user-friendly operation and maintainability. Each analyzer is thoroughly tested and factory calibrated prior to delivery. With its uniform menu navigation for simple operation and maintenance – one platform for all instruments. The self-explanatory maintenance procedures can be easily performed by the operating company.

Shurecon P
Shurecon P ± 1.5 % or ± 0.2 μS/cm - Sample temperatures up to 90°C
Shurecon S
Shurecon P ± 1 % or ± 0.2 μS/cm - Sample temperatures up to 120°C

Specifications
Measuring and control transmitter for panel installation in a Noryl® resin enclosure (front IP 54).

Sensors:
Connections for a four-electrode conductivity sensor with built-in Pt1000 temperature sensor like Swansensor Shurecon P or Shurecon S and for a digital sample flow meter.

Measuring range:
0.05 μS/cm to 100 mS/cm
Conversion to concentration selectable for aqueous solutions of many chemicals.

User interface:

  • Big backlit LC display for measuring value, sample temperature, sample flow and operating status.
  • Easy user menus in English, German, French and Spanish.
  • Simple programming of all parameters by keypad.
  • Data logger for 1’500 data records stored at a selectable interval.

Connections:

  • 2 signal outputs (0/4 – 20 mA) for measured values or continuous control.
  • 2 potential-free contacts as limit switches or as controllers, configuration normally open.
  • 1 potential-free alarm contact as summary alarm indication, default configuration normally open (option: normally closed).
  • 1 input for potential-free contact for hold or remote-off function.
  • 1 serial interface RS232 for logger download.
  • Option: Profibus DP or Modbus RTU interface.
  • All in- and outputs protected against overvoltages.

Dimensions:

  • 96 x 96 x 120 mm (DIN 43700)
  • A-87.342.1X0 Swansensor Shurecon P, 1m
  • A-87.951.001 Separate Flowmeter, incl. Flowsensor; 1m
  • A-87.951.005 Separate Flowmeter, incl. Flowsensor; 5m
  • A-87.951.007 Separate Flowmeter, incl. Flowsensor; 15m
Shurecon P
Shurecon P ± 1.5 % or ± 0.2 μS/cm - Sample temperatures up to 90°C
Shurecon S
Shurecon P ± 1 % or ± 0.2 μS/cm - Sample temperatures up to 120°C