Online Chloride Analyzer

Seres Topaz Chloride

For the continuous, selective electrode (ISE method) online determination of chloride.

Seres OL Analyzer Topaz Chloride

Online Chloride Analyzer

Complete monitoring system for the automatic, continuous measurement of chloride in potable water. Features of the Topaz online Chloride analyzer include: For the continuous, selective electrode (ISE method) online determination of chloride.
  • Available in several measuring ranges:
    • 5 to 50 ppm or
    • 5 to 100 ppm or
    • 5 to 200 ppm
  • Complete system including measurement and control electronics, measuring unit, flow indicator, reaction chamber and reagent dosing system.
  • Robust, high quality analyzer cabinet painted stainless steel, 316L.
  • Automatic, electrical zero measurement prior to each measurement cycle.
  • Automatic cell cleaning.
  • 2 easily accessible peristaltic pump modules for accurate, automatic dosing of chemical reagents.
  • 1 peristaltic pump for demineralized water to control the slope of the electrode automatically.
  • 2 analog and 7 digital outputs for alarms for process values and diagnostic alarms for each sample stream.
  • RS485 Modbus/JBUS RTU interface.
  • Large back-lit touchscreen color LCD display for the reading of all measured values and status information simultaneously.
  • Easy menu-guided operation in English or French.
The Serez OL Topaz series provides you with a high-quality industrial-grade analyzer specific to your Chloride analysis requirement.
Chloride
Potentiometric method (ISE): Measurement by selective ion electrode (ISE) combined with addition of standard:
  • Reaction time 10/11 min.
  • Topaz Chlorides 5-50/5-100/5-200 ppm
    • Repeatability 5% FS
    • Accuracy 5% FS
Complete system including measurement and control electronics, measuring unit, flow indicator, reaction chamber and reagent dosing system.

Signal outputs
  • 2 programmable signal outputs for measured values (freely scalable, linear).
  • Current loop: 4 – 20 mA
  • Communication interfaceRS485 interface (galvanically separated) with Modbus/JBUS RTU protocol.
  • Ethernet interface (TCP/IP) optional.
Relays
  • Alarm Relay s 1 summary alarm for ” analyzer failure”Maximum load:1A / 24 V
  • 2 potential-free contacts for each channel programmable as limit switches for measuring values (high/low thresholds)
  • 1 sample flow alarm for each channel
  • 1 output for indication of the active sample stream for each channel.
  • 1 output for maintenance indication.
For full details please view or download the Chloride DATE SHEET
  • Chloride in Potable Water.

Analyzer

  • Seres OL Topaz Chloride (select range from below) SOL–57.341.000

Range Selection

  • 5-50 ppm Specify in Order
  • 5-100 ppm Specify in Order
  • 5-200 ppm Specify in Order

Configuration

  • 2-Channel Setup (similar range) (similar range) SOL-83.590.020
  • 4-Channel Setup (similar range) (similar range) SOL-83.590.040
  • 6-Channel Setup (similar range) (similar range) SOL-83.590.060
  • Ethernet Interface (TCP/IP) SOL-81.410.020

Option

  • 1-Year Spare Part Package “Basis” (Analyzer + 1st channel) SOL-84.110.060
  • 1-Year Spare Part Package “Multi-Channel” (add once if multi-channel configuration was selected) SOL-84.110.150
  • Reagent shelf inf SS316L SOL-89.610.010

Reagent specifications

  • Demineralized Water RXX273
    Reagent Consumption
    4l/month (1 slope control/week)
  • Sodium Nitrate 1M RXX109
    Reagent Consumption 2.1l/month
  • Chloride Standard RXX256
    (The concentration of the standard depends on
    the range)
    Reagent Consumption 3.7l/month
  • 2 programmable signal outputs for measured values (freely scalable, linear). Current loop:4 – 20 mA
  • Communication interface RS485 interface (galvanically separated) withModbus/JBUS RTU protocol.
  • Ethernet interface (TCP/IP) optional.

Relays

  • Alarm Relay s 1 summary alarm for ” analyzer failure”Maximum load:1A / 24 V
  • 2 potential-free contacts for each channel programmable as limit switches for measuring values (high/low thresholds)
  • 1 sample flow alarm for each channel
  • 1 output for indication of the active sample stream for each channel.
  • 1 output for maintenance indication.

All Swan Analyzers are CSA Certified before shipping.

Description

Online Chloride Analyzer

Complete monitoring system for the automatic, continuous measurement of chloride in potable water. Features of the Topaz online Chloride analyzer include: For the continuous, selective electrode (ISE method) online determination of chloride.
  • Available in several measuring ranges:
    • 5 to 50 ppm or
    • 5 to 100 ppm or
    • 5 to 200 ppm
  • Complete system including measurement and control electronics, measuring unit, flow indicator, reaction chamber and reagent dosing system.
  • Robust, high quality analyzer cabinet painted stainless steel, 316L.
  • Automatic, electrical zero measurement prior to each measurement cycle.
  • Automatic cell cleaning.
  • 2 easily accessible peristaltic pump modules for accurate, automatic dosing of chemical reagents.
  • 1 peristaltic pump for demineralized water to control the slope of the electrode automatically.
  • 2 analog and 7 digital outputs for alarms for process values and diagnostic alarms for each sample stream.
  • RS485 Modbus/JBUS RTU interface.
  • Large back-lit touchscreen color LCD display for the reading of all measured values and status information simultaneously.
  • Easy menu-guided operation in English or French.
The Serez OL Topaz series provides you with a high-quality industrial-grade analyzer specific to your Chloride analysis requirement.
Chloride
Specifications
Potentiometric method (ISE): Measurement by selective ion electrode (ISE) combined with addition of standard:
  • Reaction time 10/11 min.
  • Topaz Chlorides 5-50/5-100/5-200 ppm
    • Repeatability 5% FS
    • Accuracy 5% FS
Complete system including measurement and control electronics, measuring unit, flow indicator, reaction chamber and reagent dosing system.

Signal outputs
  • 2 programmable signal outputs for measured values (freely scalable, linear).
  • Current loop: 4 – 20 mA
  • Communication interfaceRS485 interface (galvanically separated) with Modbus/JBUS RTU protocol.
  • Ethernet interface (TCP/IP) optional.
Relays
  • Alarm Relay s 1 summary alarm for ” analyzer failure”Maximum load:1A / 24 V
  • 2 potential-free contacts for each channel programmable as limit switches for measuring values (high/low thresholds)
  • 1 sample flow alarm for each channel
  • 1 output for indication of the active sample stream for each channel.
  • 1 output for maintenance indication.
For full details please view or download the Chloride DATE SHEET
Application
  • Chloride in Potable Water.
Options

Analyzer

  • Seres OL Topaz Chloride (select range from below) SOL–57.341.000

Range Selection

  • 5-50 ppm Specify in Order
  • 5-100 ppm Specify in Order
  • 5-200 ppm Specify in Order

Configuration

  • 2-Channel Setup (similar range) (similar range) SOL-83.590.020
  • 4-Channel Setup (similar range) (similar range) SOL-83.590.040
  • 6-Channel Setup (similar range) (similar range) SOL-83.590.060
  • Ethernet Interface (TCP/IP) SOL-81.410.020

Option

  • 1-Year Spare Part Package “Basis” (Analyzer + 1st channel) SOL-84.110.060
  • 1-Year Spare Part Package “Multi-Channel” (add once if multi-channel configuration was selected) SOL-84.110.150
  • Reagent shelf inf SS316L SOL-89.610.010

Reagent specifications

  • Demineralized Water RXX273
    Reagent Consumption
    4l/month (1 slope control/week)
  • Sodium Nitrate 1M RXX109
    Reagent Consumption 2.1l/month
  • Chloride Standard RXX256
    (The concentration of the standard depends on
    the range)
    Reagent Consumption 3.7l/month
Downloads
F.A.Q
  • 2 programmable signal outputs for measured values (freely scalable, linear). Current loop:4 – 20 mA
  • Communication interface RS485 interface (galvanically separated) withModbus/JBUS RTU protocol.
  • Ethernet interface (TCP/IP) optional.

Relays

  • Alarm Relay s 1 summary alarm for ” analyzer failure”Maximum load:1A / 24 V
  • 2 potential-free contacts for each channel programmable as limit switches for measuring values (high/low thresholds)
  • 1 sample flow alarm for each channel
  • 1 output for indication of the active sample stream for each channel.
  • 1 output for maintenance indication.