| SKU |
HI9829-01-web |
| Product Name |
HI9829 Multiparameter Meter pH/ISE/EC/DO/Turbidity Waterproof Meter with GPS option |
| Quote Required |
No |
| pH Range |
0.00 to 14.00 pH |
| pH Resolution |
0.01 pH |
| pH Accuracy |
±0.02 pH |
| pH Calibration |
Automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer |
| ORP Range |
±2000 mV |
| ORP Resolution |
0.1 mV |
| ORP Accuracy |
±1.0 mV |
| ORP Calibration |
automatic at one custom point (relative mV) |
| mV Range |
±600.0 mV |
| mV Resolution |
0.1 mV |
| mV Accuracy |
±0.5 mV |
| EC Range |
0 to 200 mS/cm (absolute EC up to 400 mS/cm) |
| EC Resolution |
Manual |
| EC Accuracy |
±1% of reading or ±1 µS/cm whichever is greater |
| EC Calibration |
automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
| TDS Range |
0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor) |
| TDS Resolution |
Manual |
| TDS Accuracy |
±1% of reading or ±1 ppm (mg/L), whichever is greater |
| TDS Calibration |
based on conductivity or salinity calibration |
| Salinity (PSU) Range |
0.00 to 70.00 PSU |
| Salinity (PSU) Resolution |
0.01 PSU |
| Salinity (PSU) Accuracy |
±2% of reading or ±0.01 PSU whichever is greater |
| Salinity (PSU) Calibration |
based on conductivity calibration |
| Salinity (Seawater Sigma) Range |
0.0 to 50.0 σt, σ₀, σ₁₅ |
| Salinity (Seawater Sigma) Resolution |
0.1 σt, σ₀, σ₁₅ |
| Salinity (Seawater Sigma) Accuracy |
±1 σt, σ₀, σ₁₅ |
| Salinity (Seawater Sigma) Calibration |
based on conductivity or salinity calibration |
| Resistivity Range |
0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
| Resistivity Resolution |
dependent on resistivity reading |
| Resistivity Calibration |
based on conductivity calibration |
| Dissolved Oxygen Range |
0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) |
| Dissolved Oxygen Resolution |
0.1%; 0.01 ppm (mg/L) |
| Dissolved Oxygen Accuracy |
0.0 to 300.0% saturation |
| Dissolved Oxygen Calibration |
automatic one or two points at 0 and 100% or one custom point |
| Turbidity Range |
0.0 to 99.9 FNU; 100 to 1000 FNU |
| Turbidity Resolution |
0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU |
| Turbidity Accuracy |
±0.3 FNU or ±2 % of reading, whichever is greater |
| Turbidity Calibration |
Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom |
| Temperature Range |
-5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K |
| Temperature Resolution |
0.01 K, 0.01 °C, 0.01 °F |
| Temperature Accuracy |
±0.15 °C; ±0.27 °F; ±0.15 K |
| Temperature Calibration |
automatic at one custom point |
| Temperature Compensation |
automatic from -5 to 55 °C (23 to 131 °F) |
| Ammonium Range |
0.02 to 200 ppm as NH4+-N |
| Ammonium Resolution |
0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
| Ammonium Accuracy |
±5 % reading or 2 ppm |
| Ammonium Calibration |
1 or 2 point, 10 ppm and 100 ppm |
| Chloride Rang |
e 0.6 to 200.0 ppm Cl (as Cl- ) |
| Chloride Resolution |
0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
| Chloride Accuracy |
±5 % of reading or 2 ppm |
| Chloride Calibration |
1 or 2 point, 10 ppm and 100 ppm |
| Nitrate Range |
0.62 to 200.0 ppm Ni (as NO3 – -N) |
| Nitrate Resolution |
0.01 ppm to 1 ppm 0.1 ppm to 200 ppm |
| Nitrate Calibration |
1 or 2 point, 10 ppm and 100 ppm |
| Logging Memory |
44,000 records (continuous logging or log-on-demand of all parameters) |
| Logging Interval |
one second to three hours |
| Connectivity |
USB (with HI 929829 software) |
| Battery Type/Life |
1.2V (4) NiMH, rechargeable batteries, size C type; up to 140 hours depending on configuration |
| IP Protection |
IP67 |
| Environment |
0 to 50°C (32 to 122°F); RH max 100% |
| Dimensions |
221 x 115 x 55 mm (8.7 x 4.5 x 2.2”) |
| Weight |
750 g (26.5 oz.) |
| GPS |
12 channel receiver 10 m (30 ft) accuracy |
| Ordering Information |
The HI9829 and HI98290 (GPS model) are supplied with a HI710140 hard carrying case, HI7612VDC adapter, HI7698292 probe maintenance kit, HI929829 PC application software, HI7698291 USB cable (PC to meter), HI710045 power supply cable, HI710046 cigarette lighter power cable, HI9829-25 quick calibration solution, HI920005 iButton with holder (5), HI7609829-1 pH/ORP sensor, HI7609829-2 galvanic DO sensor, HI7609829-3 EC sensor, HI7698290 short calibration beaker, HI7698295 short protective weighted shield, NiMH rechargeable “C” cell batteries (4), 12VDC power adapter, and instruction manual. |
| Atmospheric Pressure Range |
450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
| Atmospheric Pressure Resolution |
0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
| Atmospheric Pressure Accuracy |
±3 mm Hg within ±15% from calibration point |
| Atmospheric Pressure Calibration |
Automatic at one custom point |