Analyzer for the automatic and continuous measurement of specific (total) conductivity for high purity water, feedwater, steam and condensate.
- Complete system with dedicated transmitter, high precision conductivity sensor and flow cell with needle valve and digital sample flow meter.
- Quick sensor release with patented slot-lock design.
- Factory tested and ready for use.
Specific (total) conductivity for high purity water
- Selectable temperature compensations for different sample qualities and alkalizing agents
- Automatic zero verification with integrated high precision resistor
- Two-electrode titanium conductivity sensor with high precision cell constant, integrated Pt1000 temperature probe
- Patented slot lock sensor design for easy installation and release
Analytical System
- Conductivity measurement range:
- 0.055 μS/cm-30 mS/cm
- High precision:
- ± 1 % of the measured value
- Temperature compensation:
- non linear function for high purity water
- neutral salts
- strong acids
- strong bases
- Ammonia, Ethanolamine
- Morpholine
- Linear coefficient in %/°C
- Absolute (none)
- AMI Electronic Unit
- Rugged aluminum housing (IP66)
- Two freely scalable current signal outputs (0/4-20 mA), third one as an option
- Optional fieldbus communication board (Profibus, Modbus, Webserver)
- Flow-Cell with Sensors
- Stainless steel flow cell with integrated needle valve and digital sample flow meter
- Quick sensor release with patented slot-lock design.
Comprehensive monitoring of steam and condensate quality in power and industrial plants: specific conductivity
- Order Nr. Monitor AMI Powercon-Specific AC A–23.441.100
- Monitor AMI Powercon-Specific DC A–23.441.200
- Option: [ ] 3rd current signal output (0/4 – 20mA) A-81.420.050
- Profibus DP & Modbus RTU interface (RS-485) A-81.420.020
- USB interface A-81.420.042
- HART interface A-81.420.060
Flyer AMI Powercon.pdf (1777kB)
- Transmitter temperature monitoring with programmable high/low alarm limits
- 1 Alarm relay One potential free contact for summary alarm indication for programmable alarm values and instrument faults. Maximum load: 1A / 250 VAC
- 1 Input One input for potential-free contact. Programmable hold or remote off function.
- 2 Relay outputs Two potential-free contacts programmable as limit switches for measuring values, controllers or timer for system cleaning with automatic hold function. Rated load: 1A / 250 VAC
- 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bilinear) or as continuous control outputs (control parameters programmable) as current source.
- 3rd signal output selectable as cur-rent source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Control functions Relays or current outputs programmable for 1 or 2 pulse dosing pumps, solenoid valves or for one motor valve. Programmable P, PI, PID or PD control parameters.
- 1 Communication interface (option) RS485 interface (galvanically separated) with Fieldbus protocol Modbus RTU or Pro-fibus DP / 3rd Signal output / USB int
- SD card interface Possibility to record measured values and diagnostic data to an SD card. SD card included.
All Swan Analyzers are CSA Certified before shipping.
5 to 20 L/h
Analyzer for the automatic and continuous measurement of specific (total) conductivity for high purity water, feedwater, steam and condensate.
- Complete system with dedicated transmitter, high precision conductivity sensor and flow cell with needle valve and digital sample flow meter.
- Quick sensor release with patented slot-lock design.
- Factory tested and ready for use.
Specific (total) conductivity for high purity water
- Selectable temperature compensations for different sample qualities and alkalizing agents
- Automatic zero verification with integrated high precision resistor
- Two-electrode titanium conductivity sensor with high precision cell constant, integrated Pt1000 temperature probe
- Patented slot lock sensor design for easy installation and release
Analytical System
- Conductivity measurement range:
- 0.055 μS/cm-30 mS/cm
- High precision:
- ± 1 % of the measured value
- Temperature compensation:
- non linear function for high purity water
- neutral salts
- strong acids
- strong bases
- Ammonia, Ethanolamine
- Morpholine
- Linear coefficient in %/°C
- Absolute (none)
- AMI Electronic Unit
- Rugged aluminum housing (IP66)
- Two freely scalable current signal outputs (0/4-20 mA), third one as an option
- Optional fieldbus communication board (Profibus, Modbus, Webserver)
- Flow-Cell with Sensors
- Stainless steel flow cell with integrated needle valve and digital sample flow meter
- Quick sensor release with patented slot-lock design.
Comprehensive monitoring of steam and condensate quality in power and industrial plants: specific conductivity
- Order Nr. Monitor AMI Powercon-Specific AC A–23.441.100
- Monitor AMI Powercon-Specific DC A–23.441.200
- Option: [ ] 3rd current signal output (0/4 – 20mA) A-81.420.050
- Profibus DP & Modbus RTU interface (RS-485) A-81.420.020
- USB interface A-81.420.042
- HART interface A-81.420.060
Flyer AMI Powercon.pdf (1777kB)
- Transmitter temperature monitoring with programmable high/low alarm limits
- 1 Alarm relay One potential free contact for summary alarm indication for programmable alarm values and instrument faults. Maximum load: 1A / 250 VAC
- 1 Input One input for potential-free contact. Programmable hold or remote off function.
- 2 Relay outputs Two potential-free contacts programmable as limit switches for measuring values, controllers or timer for system cleaning with automatic hold function. Rated load: 1A / 250 VAC
- 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bilinear) or as continuous control outputs (control parameters programmable) as current source.
- 3rd signal output selectable as cur-rent source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Control functions Relays or current outputs programmable for 1 or 2 pulse dosing pumps, solenoid valves or for one motor valve. Programmable P, PI, PID or PD control parameters.
- 1 Communication interface (option) RS485 interface (galvanically separated) with Fieldbus protocol Modbus RTU or Pro-fibus DP / 3rd Signal output / USB int
- SD card interface Possibility to record measured values and diagnostic data to an SD card. SD card included.
All Swan Analyzers are CSA Certified before shipping.
5 to 20 L/h