Specific (total) conductivity for high purity water

AMI Powercon Specific

Specific (total) conductivity for high purity water. Two-electrode titanium sensor with high precision cell constant, integrated temperature.

Specific (total) conductivity for high purity water

Analyzer for the automatic and continuous measurement of specific (total) conductivity for high purity water, feedwater, steam and condensate.

  • Complete system with dedicated transmitter, high precision conductivity sensor and flow cell with needle valve and digital sample flow meter.
  • Quick sensor release with patented slot-lock design.
  • Factory tested and ready for use.

Specific (total) conductivity for high purity water

  • Selectable temperature compensations for different sample qualities and alkalizing agents
  • Automatic zero verification with integrated high precision resistor
  • Two-electrode titanium conductivity sensor with high precision cell constant, integrated Pt1000 temperature probe
  • Patented slot lock sensor design for easy installation and release
Specific (total) conductivity for high purity water

Analytical System

  • Conductivity measurement range:
    • 0.055 μS/cm-30 mS/cm
  • High precision:
    • ± 1 % of the measured value
  • Temperature compensation:
    • non linear function for high purity water
    • neutral salts
    • strong acids
    • strong bases
    • Ammonia, Ethanolamine
    • Morpholine
    • Linear coefficient in %/°C
    • Absolute (none)
  • AMI Electronic Unit
    • Rugged aluminum housing (IP66)
    • Two freely scalable current signal outputs (0/4-20 mA), third one as an option
    • Optional fieldbus communication board (Profibus, Modbus, Webserver)
  • Flow-Cell with Sensors
    • Stainless steel flow cell with integrated needle valve and digital sample flow meter
    • Quick sensor release with patented slot-lock design.

Comprehensive monitoring of steam and condensate quality in power and industrial plants: specific conductivity

  • Order Nr. Monitor AMI Powercon-Specific AC A–23.441.100
  • Monitor AMI Powercon-Specific DC A–23.441.200
  • Option: [ ] 3rd current signal output (0/4 – 20mA) A-81.420.050
  • Profibus DP & Modbus RTU interface (RS-485) A-81.420.020
  • USB interface A-81.420.042
  • HART interface A-81.420.060
  • Transmitter temperature monitoring with programmable high/low alarm limits
  • 1 Alarm relay One potential free contact for summary alarm indication for programmable alarm values and instrument faults. Maximum load: 1A / 250 VAC
  • 1 Input One input for potential-free contact. Programmable hold or remote off function.
  • 2 Relay outputs Two potential-free contacts programmable as limit switches for measuring values, controllers or timer for system cleaning with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bilinear) or as continuous control outputs (control parameters programmable) as current source.
  • 3rd signal output selectable as cur-rent source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Control functions Relays or current outputs programmable for 1 or 2 pulse dosing pumps, solenoid valves or for one motor valve. Programmable P, PI, PID or PD control parameters.
  • 1 Communication interface (option) RS485 interface (galvanically separated) with Fieldbus protocol Modbus RTU or Pro-fibus DP / 3rd Signal output / USB int
  • SD card interface Possibility to record measured values and diagnostic data to an SD card. SD card included.

All Swan Analyzers are CSA Certified before shipping.

Description

Analyzer for the automatic and continuous measurement of specific (total) conductivity for high purity water, feedwater, steam and condensate.

  • Complete system with dedicated transmitter, high precision conductivity sensor and flow cell with needle valve and digital sample flow meter.
  • Quick sensor release with patented slot-lock design.
  • Factory tested and ready for use.

Specific (total) conductivity for high purity water

  • Selectable temperature compensations for different sample qualities and alkalizing agents
  • Automatic zero verification with integrated high precision resistor
  • Two-electrode titanium conductivity sensor with high precision cell constant, integrated Pt1000 temperature probe
  • Patented slot lock sensor design for easy installation and release
Specific (total) conductivity for high purity water
Specifications

Analytical System

  • Conductivity measurement range:
    • 0.055 μS/cm-30 mS/cm
  • High precision:
    • ± 1 % of the measured value
  • Temperature compensation:
    • non linear function for high purity water
    • neutral salts
    • strong acids
    • strong bases
    • Ammonia, Ethanolamine
    • Morpholine
    • Linear coefficient in %/°C
    • Absolute (none)
  • AMI Electronic Unit
    • Rugged aluminum housing (IP66)
    • Two freely scalable current signal outputs (0/4-20 mA), third one as an option
    • Optional fieldbus communication board (Profibus, Modbus, Webserver)
  • Flow-Cell with Sensors
    • Stainless steel flow cell with integrated needle valve and digital sample flow meter
    • Quick sensor release with patented slot-lock design.
Application

Comprehensive monitoring of steam and condensate quality in power and industrial plants: specific conductivity

Options
  • Order Nr. Monitor AMI Powercon-Specific AC A–23.441.100
  • Monitor AMI Powercon-Specific DC A–23.441.200
  • Option: [ ] 3rd current signal output (0/4 – 20mA) A-81.420.050
  • Profibus DP & Modbus RTU interface (RS-485) A-81.420.020
  • USB interface A-81.420.042
  • HART interface A-81.420.060
Downloads
F.A.Q
  • Transmitter temperature monitoring with programmable high/low alarm limits
  • 1 Alarm relay One potential free contact for summary alarm indication for programmable alarm values and instrument faults. Maximum load: 1A / 250 VAC
  • 1 Input One input for potential-free contact. Programmable hold or remote off function.
  • 2 Relay outputs Two potential-free contacts programmable as limit switches for measuring values, controllers or timer for system cleaning with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bilinear) or as continuous control outputs (control parameters programmable) as current source.
  • 3rd signal output selectable as cur-rent source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Control functions Relays or current outputs programmable for 1 or 2 pulse dosing pumps, solenoid valves or for one motor valve. Programmable P, PI, PID or PD control parameters.
  • 1 Communication interface (option) RS485 interface (galvanically separated) with Fieldbus protocol Modbus RTU or Pro-fibus DP / 3rd Signal output / USB int
  • SD card interface Possibility to record measured values and diagnostic data to an SD card. SD card included.

All Swan Analyzers are CSA Certified before shipping.