- Description
- Specification
- Application
- Options
- Downloads
- F.A.Q
Complete monitoring of Specific (total) Conductivity for Feed Water, Cooling Water and Effluents. Continuous measurement of specific conductivity, concentration of CIP solutions, salinity and TDS.
- Monitor AMI Solicon4 consisting of accurate 4-electrode conductivity sensor, user-friendly transmitter and flow cell
- Applications in surface water, potable water and effluents
- Temperature compensation with selectable coefficient or non-linear function according to EN 27888/ DIN 38404
- Precise quality-system: inexpensive, low maintenance, and simple to handle
- Complete panel mounted system; tested, calibrated and ready for operation
- Option: Swansensor deltaT for flow detection.
Transmitter / Controller
- Rugged aluminium housing IP66
- Easy full text menu guidance
- Internal data logger
- Programmable PID controllers
- 2 free programmable signal outputs (4 – 20 mA)
- 2 potential free contacts programmable as PID controllers, limit or alarm switches
- Internal data logging including alarms, events and calibration data
Swansensor Shurecon P
- 4-electrode platinum design with built-in Pt1000 temperature sensor.
- Accurate and low-maintenance sensor: unaffected by fouling.
- Measuring range: 0.1 μS/cm … 100 mS/cm.
- Operating conditions for complete monitor system: temperature up to 50°C and pressure up to 1 bar.
Flow cell M-Flow PG
- Made of PVC with quick-connect vessel made of acrylic glass for easy sensor calibration and maintenance.
Analytical System
- Conductivity measurement range:
- 0.055 μS/cm-30 mS/cm
- High precision:
- ± 1 % of the measured value
- Temperature compensation:
- non linear function for high purity water
- neutral salts
- strong acids
- strong bases
- Ammonia, Ethanolamine
- Morpholine
- Linear coefficient in %/°C
- Absolute (none)
- AMI Electronic Unit
- Rugged aluminum housing (IP66)
- Two freely scalable current signal outputs (0/4-20 mA), third one as an option
- Optional fieldbus communication board (Profibus, Modbus, Webserver)
- Flow-Cell with Sensors
- Stainless steel flow cell with integrated needle valve and digital sample flow meter
- Quick sensor release with patented slot-lock design.
- Comprehensive monitoring of surface water, cooling water and effluents.
- Intake Water.
Consumables
Order/No. | Description |
---|---|
A-85.131.700 | OXYCON RC 1,413 |
Accessories
Order/No. | Description |
---|---|
A-81.420.020 | AMI Option; Profibus- / Modbus Interface |
A-81.420.042 | AMI Option; USB Interface |
A-81.420.050 | AMI Option; 3rd signal output |
A-81.420.060 | AMI Option; HART Interface |
A-87.933.010 | Swansensor Flow deltaT |
A-88.224.220 | Communication cable, AMI to PC, 2 m |
Spare parts
Order/No. | Description |
---|---|
A-83.437.330 | Flow cell M-Flow PG |
A-87.342.1X0 | Swansensor Shurecon P, 1m |
A-89.811.060 | Set of fuses for AMI |
Flyer AMI Solicon 4.pdf (1777kB)
- Transmitter temperature monitoring with programmable high/low alarm limits
- 1 Alarm relay One potential free contact for summary alarm indication for programmable alarm values and instrument faults. Maximum load: 1A / 250 VAC
- 1 Input One input for potential-free contact. Programmable hold or remote off function.
- 2 Relay outputs Two potential-free contacts programmable as limit switches for measuring values, controllers or timer for system cleaning with automatic hold function. Rated load: 1A / 250 VAC
- 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bilinear) or as continuous control outputs (control parameters programmable) as current source.
- 3rd signal output selectable as cur-rent source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Control functions Relays or current outputs programmable for 1 or 2 pulse dosing pumps, solenoid valves or for one motor valve. Programmable P, PI, PID or PD control parameters.
- 1 Communication interface (option) RS485 interface (galvanically separated) with Fieldbus protocol Modbus RTU or Pro-fibus DP / 3rd Signal output / USB int
- SD card interface Possibility to record measured values and diagnostic data to an SD card. SD card included.
All Swan Analyzers are CSA Certified before shipping.
5 to 20 L/h
Description
Complete monitoring of Specific (total) Conductivity for Feed Water, Cooling Water and Effluents. Continuous measurement of specific conductivity, concentration of CIP solutions, salinity and TDS.
- Monitor AMI Solicon4 consisting of accurate 4-electrode conductivity sensor, user-friendly transmitter and flow cell
- Applications in surface water, potable water and effluents
- Temperature compensation with selectable coefficient or non-linear function according to EN 27888/ DIN 38404
- Precise quality-system: inexpensive, low maintenance, and simple to handle
- Complete panel mounted system; tested, calibrated and ready for operation
- Option: Swansensor deltaT for flow detection.
Transmitter / Controller
- Rugged aluminium housing IP66
- Easy full text menu guidance
- Internal data logger
- Programmable PID controllers
- 2 free programmable signal outputs (4 – 20 mA)
- 2 potential free contacts programmable as PID controllers, limit or alarm switches
- Internal data logging including alarms, events and calibration data
Swansensor Shurecon P
- 4-electrode platinum design with built-in Pt1000 temperature sensor.
- Accurate and low-maintenance sensor: unaffected by fouling.
- Measuring range: 0.1 μS/cm … 100 mS/cm.
- Operating conditions for complete monitor system: temperature up to 50°C and pressure up to 1 bar.
Flow cell M-Flow PG
- Made of PVC with quick-connect vessel made of acrylic glass for easy sensor calibration and maintenance.
Specifications
Analytical System
- Conductivity measurement range:
- 0.055 μS/cm-30 mS/cm
- High precision:
- ± 1 % of the measured value
- Temperature compensation:
- non linear function for high purity water
- neutral salts
- strong acids
- strong bases
- Ammonia, Ethanolamine
- Morpholine
- Linear coefficient in %/°C
- Absolute (none)
- AMI Electronic Unit
- Rugged aluminum housing (IP66)
- Two freely scalable current signal outputs (0/4-20 mA), third one as an option
- Optional fieldbus communication board (Profibus, Modbus, Webserver)
- Flow-Cell with Sensors
- Stainless steel flow cell with integrated needle valve and digital sample flow meter
- Quick sensor release with patented slot-lock design.
Application
- Comprehensive monitoring of surface water, cooling water and effluents.
- Intake Water.
Options
Consumables
Order/No. | Description |
---|---|
A-85.131.700 | OXYCON RC 1,413 |
Accessories
Order/No. | Description |
---|---|
A-81.420.020 | AMI Option; Profibus- / Modbus Interface |
A-81.420.042 | AMI Option; USB Interface |
A-81.420.050 | AMI Option; 3rd signal output |
A-81.420.060 | AMI Option; HART Interface |
A-87.933.010 | Swansensor Flow deltaT |
A-88.224.220 | Communication cable, AMI to PC, 2 m |
Spare parts
Order/No. | Description |
---|---|
A-83.437.330 | Flow cell M-Flow PG |
A-87.342.1X0 | Swansensor Shurecon P, 1m |
A-89.811.060 | Set of fuses for AMI |
Downloads
Flyer AMI Solicon 4.pdf (1777kB)
F.A.Q
- Transmitter temperature monitoring with programmable high/low alarm limits
- 1 Alarm relay One potential free contact for summary alarm indication for programmable alarm values and instrument faults. Maximum load: 1A / 250 VAC
- 1 Input One input for potential-free contact. Programmable hold or remote off function.
- 2 Relay outputs Two potential-free contacts programmable as limit switches for measuring values, controllers or timer for system cleaning with automatic hold function. Rated load: 1A / 250 VAC
- 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bilinear) or as continuous control outputs (control parameters programmable) as current source.
- 3rd signal output selectable as cur-rent source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Control functions Relays or current outputs programmable for 1 or 2 pulse dosing pumps, solenoid valves or for one motor valve. Programmable P, PI, PID or PD control parameters.
- 1 Communication interface (option) RS485 interface (galvanically separated) with Fieldbus protocol Modbus RTU or Pro-fibus DP / 3rd Signal output / USB int
- SD card interface Possibility to record measured values and diagnostic data to an SD card. SD card included.
All Swan Analyzers are CSA Certified before shipping.
5 to 20 L/h