Specific (total) Conductivity for Feed Water, Cooling Water and Effluents

AMI Solicon 4

Specific (total) Conductivity for Feed Water. Accurate 4-electrode conductivity sensor, user-friendly transmitter and flow cell.

Specific (total) Conductivity for Feed Water. Accurate 4-electrode conductivity sensor, user-friendly transmitter and flow cell.

Complete monitoring of Specific (total) Conductivity for Feed Water, Cooling Water and Effluents. Continuous measurement of specific conductivity, concentration of CIP solutions, salinity and TDS.

  • Monitor AMI Solicon4 consisting of accurate 4-electrode conductivity sensor, user-friendly transmitter and flow cell
  • Applications in surface water, potable water and effluents
  • Temperature compensation with selectable coefficient or non-linear function according to EN 27888/ DIN 38404
  • Precise quality-system: inexpensive, low maintenance, and simple to handle
  • Complete panel mounted system; tested, calibrated and ready for operation
  • Option: Swansensor deltaT for flow detection.

Transmitter / Controller

  • Rugged aluminium housing IP66
  • Easy full text menu guidance
  • Internal data logger
  • Programmable PID controllers
  • 2 free programmable signal outputs (4 – 20 mA)
  • 2 potential free contacts programmable as PID controllers, limit or alarm switches
  • Internal data logging including alarms, events and calibration data

Swansensor Shurecon P

  • 4-electrode platinum design with built-in Pt1000 temperature sensor.
  • Accurate and low-maintenance sensor: unaffected by fouling.
  • Measuring range: 0.1 μS/cm … 100 mS/cm.
  • Operating conditions for complete monitor system: temperature up to 50°C and pressure up to 1 bar.

Flow cell M-Flow PG

  • Made of PVC with quick-connect vessel made of acrylic glass for easy sensor calibration and maintenance.
Complete monitoring system for the automatic, continuous measurement of the specific conductivity, concentration of CIP solutions, salinity and TDS in surface water, potable water and cooling water.

Analytical System

  • Conductivity measurement range:
    • 0.055 μS/cm-30 mS/cm
  • High precision:
    • ± 1 % of the measured value
  • Temperature compensation:
    • non linear function for high purity water
    • neutral salts
    • strong acids
    • strong bases
    • Ammonia, Ethanolamine
    • Morpholine
    • Linear coefficient in %/°C
    • Absolute (none)
  • AMI Electronic Unit
    • Rugged aluminum housing (IP66)
    • Two freely scalable current signal outputs (0/4-20 mA), third one as an option
    • Optional fieldbus communication board (Profibus, Modbus, Webserver)
  • Flow-Cell with Sensors
    • Stainless steel flow cell with integrated needle valve and digital sample flow meter
    • Quick sensor release with patented slot-lock design.
  • Comprehensive monitoring of surface water, cooling water and effluents.
  • Intake Water.

Consumables

Order/No.Description
A-85.131.700OXYCON RC 1,413

Accessories

Order/No.Description
A-81.420.020AMI Option; Profibus- / Modbus Interface
A-81.420.042AMI Option; USB Interface
A-81.420.050AMI Option; 3rd signal output
A-81.420.060AMI Option; HART Interface
A-87.933.010Swansensor Flow deltaT
A-88.224.220Communication cable, AMI to PC, 2 m

Spare parts

Order/No.Description
A-83.437.330Flow cell M-Flow PG
A-87.342.1X0Swansensor Shurecon P, 1m
A-89.811.060Set of fuses for AMI
  • Transmitter temperature monitoring with programmable high/low alarm limits
  • 1 Alarm relay One potential free contact for summary alarm indication for programmable alarm values and instrument faults. Maximum load: 1A / 250 VAC
  • 1 Input One input for potential-free contact. Programmable hold or remote off function.
  • 2 Relay outputs Two potential-free contacts programmable as limit switches for measuring values, controllers or timer for system cleaning with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bilinear) or as continuous control outputs (control parameters programmable) as current source.
  • 3rd signal output selectable as cur-rent source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Control functions Relays or current outputs programmable for 1 or 2 pulse dosing pumps, solenoid valves or for one motor valve. Programmable P, PI, PID or PD control parameters.
  • 1 Communication interface (option) RS485 interface (galvanically separated) with Fieldbus protocol Modbus RTU or Pro-fibus DP / 3rd Signal output / USB int
  • SD card interface Possibility to record measured values and diagnostic data to an SD card. SD card included.

All Swan Analyzers are CSA Certified before shipping.

Description

Complete monitoring of Specific (total) Conductivity for Feed Water, Cooling Water and Effluents. Continuous measurement of specific conductivity, concentration of CIP solutions, salinity and TDS.

  • Monitor AMI Solicon4 consisting of accurate 4-electrode conductivity sensor, user-friendly transmitter and flow cell
  • Applications in surface water, potable water and effluents
  • Temperature compensation with selectable coefficient or non-linear function according to EN 27888/ DIN 38404
  • Precise quality-system: inexpensive, low maintenance, and simple to handle
  • Complete panel mounted system; tested, calibrated and ready for operation
  • Option: Swansensor deltaT for flow detection.

Transmitter / Controller

  • Rugged aluminium housing IP66
  • Easy full text menu guidance
  • Internal data logger
  • Programmable PID controllers
  • 2 free programmable signal outputs (4 – 20 mA)
  • 2 potential free contacts programmable as PID controllers, limit or alarm switches
  • Internal data logging including alarms, events and calibration data

Swansensor Shurecon P

  • 4-electrode platinum design with built-in Pt1000 temperature sensor.
  • Accurate and low-maintenance sensor: unaffected by fouling.
  • Measuring range: 0.1 μS/cm … 100 mS/cm.
  • Operating conditions for complete monitor system: temperature up to 50°C and pressure up to 1 bar.

Flow cell M-Flow PG

  • Made of PVC with quick-connect vessel made of acrylic glass for easy sensor calibration and maintenance.
Complete monitoring system for the automatic, continuous measurement of the specific conductivity, concentration of CIP solutions, salinity and TDS in surface water, potable water and cooling water.
Specifications

Analytical System

  • Conductivity measurement range:
    • 0.055 μS/cm-30 mS/cm
  • High precision:
    • ± 1 % of the measured value
  • Temperature compensation:
    • non linear function for high purity water
    • neutral salts
    • strong acids
    • strong bases
    • Ammonia, Ethanolamine
    • Morpholine
    • Linear coefficient in %/°C
    • Absolute (none)
  • AMI Electronic Unit
    • Rugged aluminum housing (IP66)
    • Two freely scalable current signal outputs (0/4-20 mA), third one as an option
    • Optional fieldbus communication board (Profibus, Modbus, Webserver)
  • Flow-Cell with Sensors
    • Stainless steel flow cell with integrated needle valve and digital sample flow meter
    • Quick sensor release with patented slot-lock design.
Application
  • Comprehensive monitoring of surface water, cooling water and effluents.
  • Intake Water.
Options

Consumables

Order/No.Description
A-85.131.700OXYCON RC 1,413

Accessories

Order/No.Description
A-81.420.020AMI Option; Profibus- / Modbus Interface
A-81.420.042AMI Option; USB Interface
A-81.420.050AMI Option; 3rd signal output
A-81.420.060AMI Option; HART Interface
A-87.933.010Swansensor Flow deltaT
A-88.224.220Communication cable, AMI to PC, 2 m

Spare parts

Order/No.Description
A-83.437.330Flow cell M-Flow PG
A-87.342.1X0Swansensor Shurecon P, 1m
A-89.811.060Set of fuses for AMI
Downloads
F.A.Q
  • Transmitter temperature monitoring with programmable high/low alarm limits
  • 1 Alarm relay One potential free contact for summary alarm indication for programmable alarm values and instrument faults. Maximum load: 1A / 250 VAC
  • 1 Input One input for potential-free contact. Programmable hold or remote off function.
  • 2 Relay outputs Two potential-free contacts programmable as limit switches for measuring values, controllers or timer for system cleaning with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bilinear) or as continuous control outputs (control parameters programmable) as current source.
  • 3rd signal output selectable as cur-rent source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Control functions Relays or current outputs programmable for 1 or 2 pulse dosing pumps, solenoid valves or for one motor valve. Programmable P, PI, PID or PD control parameters.
  • 1 Communication interface (option) RS485 interface (galvanically separated) with Fieldbus protocol Modbus RTU or Pro-fibus DP / 3rd Signal output / USB int
  • SD card interface Possibility to record measured values and diagnostic data to an SD card. SD card included.

All Swan Analyzers are CSA Certified before shipping.