AMI Inspector Hydrogen

Portable inspection equipment for trace measurement of dissolved hydrogen in water steam cycle.

Portable Trace Hydrogen Measurement

Portable inspection equipment for trace measurement of dissolved hydrogen in water steam cycle.

Portable Trace Hydrogen Monitor Features:

  • Complete portable system mounted on small, aluminum panel:
  • Transmitter AMI INSPECTOR Hydrogen in a rugged aluminum enclosure (IP 66).
  • Swansensor Hydrogen with platinum anode and integrated NT5k temperature sensor.
  • Flow cell QV-Flow PMMA OTG made of acrylic glass with needle valve and digital sample flow meter.
  • Rechargeable battery for stand-alone operation.
  • Carrying case
  • USB Stick for data logging.
  • Factory tested, ready for installation and operation.
Hyfrogen
Specifications:
  • Measuring range: 0.1 ppb to 800 ppb H2 (at 25°C, 1013hPa) or 0 – 50% saturation.
  • Big LC display for the reading of measuring value, sample temperature, sample flow, operating status and battery charge condition.
  • Easy user menus in English, German, French and Spanish. Simple programming of all parameters by keypad.
  • Electronic record of major process events and calibration data.
  • Data logger for 1’500 data records stored at a selectable interval.
  • One current output (0/4 – 20 mA) for measured signal.
Detailed Specification can be found on Page 2 of the Hydrogen monitor Data Sheet.
  • Water Steam Cycle.
  • Pure and Ultrapure Water Applications
  • Power Plants
Accessories
  • V-9700910 Service Hydrogen sensor including calibration and labeling
Spare parts
  • A-87.260.001 Swansensor Hydrogen
  • A-88.155.X20 Sensor cable for Sensors with M16 plug
  • A-89.819.020 Exchange battery for AMI Inspector; V2
  • C-89.700.030 Case Inspector
  • C-89.819.010 Power adapter for AMI Inspector; V2
  • 2 Relay outputs Two potential-free contacts program-able as limit switches for measuring values, controllers or timer with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bi-linear) or as continuous control out-put (control parameters programmable) as current source. 3rd signal output selectable as current source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Ω
  • Optional Profibus- / Modbus Interface
  • Optional HART Interface
  • Optional USB Interface
  • Optional Third 0/4 – 20  mA Output

All Swan Analyzers are CSA Certified before shipping.

Description

Portable inspection equipment for trace measurement of dissolved hydrogen in water steam cycle.

Portable Trace Hydrogen Monitor Features:

  • Complete portable system mounted on small, aluminum panel:
  • Transmitter AMI INSPECTOR Hydrogen in a rugged aluminum enclosure (IP 66).
  • Swansensor Hydrogen with platinum anode and integrated NT5k temperature sensor.
  • Flow cell QV-Flow PMMA OTG made of acrylic glass with needle valve and digital sample flow meter.
  • Rechargeable battery for stand-alone operation.
  • Carrying case
  • USB Stick for data logging.
  • Factory tested, ready for installation and operation.
Hyfrogen
Specifications
Specifications:
  • Measuring range: 0.1 ppb to 800 ppb H2 (at 25°C, 1013hPa) or 0 – 50% saturation.
  • Big LC display for the reading of measuring value, sample temperature, sample flow, operating status and battery charge condition.
  • Easy user menus in English, German, French and Spanish. Simple programming of all parameters by keypad.
  • Electronic record of major process events and calibration data.
  • Data logger for 1’500 data records stored at a selectable interval.
  • One current output (0/4 – 20 mA) for measured signal.
Detailed Specification can be found on Page 2 of the Hydrogen monitor Data Sheet.
Application
  • Water Steam Cycle.
  • Pure and Ultrapure Water Applications
  • Power Plants
Options
Accessories
  • V-9700910 Service Hydrogen sensor including calibration and labeling
Spare parts
  • A-87.260.001 Swansensor Hydrogen
  • A-88.155.X20 Sensor cable for Sensors with M16 plug
  • A-89.819.020 Exchange battery for AMI Inspector; V2
  • C-89.700.030 Case Inspector
  • C-89.819.010 Power adapter for AMI Inspector; V2
Downloads
F.A.Q.
  • 2 Relay outputs Two potential-free contacts program-able as limit switches for measuring values, controllers or timer with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bi-linear) or as continuous control out-put (control parameters programmable) as current source. 3rd signal output selectable as current source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Ω
  • Optional Profibus- / Modbus Interface
  • Optional HART Interface
  • Optional USB Interface
  • Optional Third 0/4 – 20  mA Output

All Swan Analyzers are CSA Certified before shipping.