wjf-logo
1 877 291 5572    |    Contact Us    |    Search

Portable Hydrogen Monitor Quality Assurance Inspector

AMI Inspector Hydrogen

Portable inspection equipment for trace measurement of dissolved hydrogen in water steam cycle.

Portable Trace Hydrogen Measurement
  • Description
  • Specification
  • Application
  • Options
  • Downloads
  • F.A.Q.

Portable inspection equipment for trace measurement of dissolved hydrogen in water steam cycle.

Portable Trace Hydrogen Monitor Features:

  • Complete portable system mounted on small, aluminum panel:
  • Transmitter AMI INSPECTOR Hydrogen in a rugged aluminum enclosure (IP 66).
  • Swansensor Hydrogen with platinum anode and integrated NT5k temperature sensor.
  • Flow cell QV-Flow PMMA OTG made of acrylic glass with needle valve and digital sample flow meter.
  • Rechargeable battery for stand-alone operation.
  • Carrying case
  • USB Stick for data logging.
  • Factory tested, ready for installation and operation.
Hyfrogen
Specifications:
  • Measuring range: 0.1 ppb to 800 ppb H2 (at 25°C, 1013hPa) or 0 – 50% saturation.
  • Big LC display for the reading of measuring value, sample temperature, sample flow, operating status and battery charge condition.
  • Easy user menus in English, German, French and Spanish. Simple programming of all parameters by keypad.
  • Electronic record of major process events and calibration data.
  • Data logger for 1’500 data records stored at a selectable interval.
  • One current output (0/4 – 20 mA) for measured signal.
Detailed Specification can be found on Page 2 of the Hydrogen monitor Data Sheet.
  • Water Steam Cycle.
  • Pure and Ultrapure Water Applications
  • Power Plants
Accessories
  • V-9700910 Service Hydrogen sensor including calibration and labeling
Spare parts
  • A-87.260.001 Swansensor Hydrogen
  • A-88.155.X20 Sensor cable for Sensors with M16 plug
  • A-89.819.020 Exchange battery for AMI Inspector; V2
  • C-89.700.030 Case Inspector
  • C-89.819.010 Power adapter for AMI Inspector; V2
  • 2 Relay outputs Two potential-free contacts program-able as limit switches for measuring values, controllers or timer with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bi-linear) or as continuous control out-put (control parameters programmable) as current source. 3rd signal output selectable as current source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Ω
  • Optional Profibus- / Modbus Interface
  • Optional HART Interface
  • Optional USB Interface
  • Optional Third 0/4 – 20  mA Output

All Swan Analyzers are CSA Cirtified at our premises before shipping.

Portable inspection equipment for trace measurement of dissolved hydrogen in water steam cycle.

Portable Trace Hydrogen Monitor Features:

  • Complete portable system mounted on small, aluminum panel:
  • Transmitter AMI INSPECTOR Hydrogen in a rugged aluminum enclosure (IP 66).
  • Swansensor Hydrogen with platinum anode and integrated NT5k temperature sensor.
  • Flow cell QV-Flow PMMA OTG made of acrylic glass with needle valve and digital sample flow meter.
  • Rechargeable battery for stand-alone operation.
  • Carrying case
  • USB Stick for data logging.
  • Factory tested, ready for installation and operation.
Hyfrogen
Specifications:
  • Measuring range: 0.1 ppb to 800 ppb H2 (at 25°C, 1013hPa) or 0 – 50% saturation.
  • Big LC display for the reading of measuring value, sample temperature, sample flow, operating status and battery charge condition.
  • Easy user menus in English, German, French and Spanish. Simple programming of all parameters by keypad.
  • Electronic record of major process events and calibration data.
  • Data logger for 1’500 data records stored at a selectable interval.
  • One current output (0/4 – 20 mA) for measured signal.
Detailed Specification can be found on Page 2 of the Hydrogen monitor Data Sheet.
  • Water Steam Cycle.
  • Pure and Ultrapure Water Applications
  • Power Plants
Accessories
  • V-9700910 Service Hydrogen sensor including calibration and labeling
Spare parts
  • A-87.260.001 Swansensor Hydrogen
  • A-88.155.X20 Sensor cable for Sensors with M16 plug
  • A-89.819.020 Exchange battery for AMI Inspector; V2
  • C-89.700.030 Case Inspector
  • C-89.819.010 Power adapter for AMI Inspector; V2
  • 2 Relay outputs Two potential-free contacts program-able as limit switches for measuring values, controllers or timer with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bi-linear) or as continuous control out-put (control parameters programmable) as current source. 3rd signal output selectable as current source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Ω
  • Optional Profibus- / Modbus Interface
  • Optional HART Interface
  • Optional USB Interface
  • Optional Third 0/4 – 20  mA Output

All Swan Analyzers are CSA Cirtified at our premises before shipping.