wjf-logo
1 877 291 5572    |    Contact Us    |    Search

pH or redox Monitor

AMI pH-Redox QV-Flow AC

pH or redox (ORP) in high purity water, steam and condensate.

pH or redox (ORP) in high purity water, steam and condensate.

Monitor for continuous measurement of pH or redox (ORP) in high purity water, steam and condensate.

pH or redox Monitor Features:

Complete system mounted on stainless steel panel:

  • Transmitter AMI pH-Redox in a rugged aluminum enclosure (IP 66).
  • Measuring range: 1 to 13 pH respectively -500 to +1’500mV depending on installed sensor.
  • Various combined or separated sensors with reference electrodes available.
  • Flow cell QV-Flow IS1000 made of stainless steel with quick release vessel for easy calibration, needle valve, digital sample flow meter and temperature sensor.
  • Factory tested, ready for installation and operation.

Special features for high purity water with Nernst plus solution temperature compensation.

pH Redox Monitor Analyzer

Specifications:

Complete system mounted on stainless steel mounting panel.

Transmitter in aluminum housing (IP 66) with 2 signal outputs for measuring value or for continuous control, 2 relays as limit switch or controller or timer, 1 alarm relay as summary alarm contact, 1 input for potential-free contact.

Flow cell QV-Flow pHT1000 made of stainless steel SS316L with built-in temperature sensor, flow adjustment valve and digital sample flow meter for two PG13.5 sensors.

  • Measuring range:
    • with Swansensor ST: 1.00 to 13.00 pH respectively -400 to +1’200 mV
    • with Swansensor SI/FL: 1.00 to 12.00 pH respectively -500 to +1’500 m
  • Process connections:
    • Inlet: Swagelok ¼” tube adapter
    • Outlet: G ½” adapter for flexible tube Ø 20 x 15 mm, pressure-free
  • Power Supply
    • 100-240 VAC (±10%)
    • 10-36 VDC
  • Simultaneous measurement of pH or redox, sample temperature and sample flow.
  • Big backlit LC display for the reading of measuring value, sample temperature,
    sample flow and operating status.
  • Easy user menus with simple programming of all parameters by keypad.
  • Two current outputs (0/4 – 20 mA) for measured signals (3rd output optional).

Detailed Specification can be found on Page 2 of the AMI pH-redox monitor Data Sheet.

  • Feed Water.
  • Steam.
  • Condensate.
  • Pure and Ultrapure Water Applications.
  • Power Plants.
Consumables
  • A-85.113.300 Calibration solution pH 7 40ml
  • A-85.114.300 Calibration solution pH 9 40ml
  • A-85.119.010 pH-Calibration set (1x pH 7, 1x pH 9, each 40 ml)
  • A-85.121.300 Redox buffer 475mV, 40ml
  • A-87.893.500 Filling solution 3,5M for Swansensor pH SI+FL; 200ml
Accessories
  • A-75.100.000 QS-Monitor AMI INSPECTOR pH
  • A-81.420.020 AMI Option; Profibus- / Modbus Interface
  • A-81.420.042 AMI Option; USB Interface
  • A-81.420.050 AMI Option; 3rd signal output
  • A-81.420.060 AMI Option; HART Interface
  • A-83.910.120 Screw fitting 12mm/PG 13,5 plus distance sleeve
  • A-87.110.200 Swansensor pH SI
  • A-87.150.200 Swansensor pH FL
  • A-87.410.200 Swansensor Redox SI
  • A-87.411.200 Swansensor Redox FL
  • A-87.860.100 Swansensor Reference FL
  • A-88.121.120 Sensor cable 0.4 meters sleeves/screw plug
  • A-88.224.220 Communication cable, AMI to PC, 2 m
Spare parts
  • A-88.121.120 Sensor cable 0.4 meters sleeves/screw plug
  • A-89.811.060 Set of fuses for AMI
  • 2 Relay outputs Two potential-free contacts program-able as limit switches for measuring values, controllers or timer with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bi-linear) or as continuous control out-put (control parameters programmable) as current source. 3rd signal output selectable as current source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Ω
  • Optional Profibus- / Modbus Interface
  • Optional HART Interface
  • Optional USB Interface
  • Optional Third 0/4 – 20  mA Output

All Swan Analyzers are CSA Certified before shipping.

Flow rate: 5 to 10 l/h

Description

Monitor for continuous measurement of pH or redox (ORP) in high purity water, steam and condensate.

pH or redox Monitor Features:

Complete system mounted on stainless steel panel:

  • Transmitter AMI pH-Redox in a rugged aluminum enclosure (IP 66).
  • Measuring range: 1 to 13 pH respectively -500 to +1’500mV depending on installed sensor.
  • Various combined or separated sensors with reference electrodes available.
  • Flow cell QV-Flow IS1000 made of stainless steel with quick release vessel for easy calibration, needle valve, digital sample flow meter and temperature sensor.
  • Factory tested, ready for installation and operation.

Special features for high purity water with Nernst plus solution temperature compensation.

pH Redox Monitor Analyzer
Specifications

Specifications:

Complete system mounted on stainless steel mounting panel.

Transmitter in aluminum housing (IP 66) with 2 signal outputs for measuring value or for continuous control, 2 relays as limit switch or controller or timer, 1 alarm relay as summary alarm contact, 1 input for potential-free contact.

Flow cell QV-Flow pHT1000 made of stainless steel SS316L with built-in temperature sensor, flow adjustment valve and digital sample flow meter for two PG13.5 sensors.

  • Measuring range:
    • with Swansensor ST: 1.00 to 13.00 pH respectively -400 to +1’200 mV
    • with Swansensor SI/FL: 1.00 to 12.00 pH respectively -500 to +1’500 m
  • Process connections:
    • Inlet: Swagelok ¼” tube adapter
    • Outlet: G ½” adapter for flexible tube Ø 20 x 15 mm, pressure-free
  • Power Supply
    • 100-240 VAC (±10%)
    • 10-36 VDC
  • Simultaneous measurement of pH or redox, sample temperature and sample flow.
  • Big backlit LC display for the reading of measuring value, sample temperature,
    sample flow and operating status.
  • Easy user menus with simple programming of all parameters by keypad.
  • Two current outputs (0/4 – 20 mA) for measured signals (3rd output optional).

Detailed Specification can be found on Page 2 of the AMI pH-redox monitor Data Sheet.

Application
  • Feed Water.
  • Steam.
  • Condensate.
  • Pure and Ultrapure Water Applications.
  • Power Plants.
Options
Consumables
  • A-85.113.300 Calibration solution pH 7 40ml
  • A-85.114.300 Calibration solution pH 9 40ml
  • A-85.119.010 pH-Calibration set (1x pH 7, 1x pH 9, each 40 ml)
  • A-85.121.300 Redox buffer 475mV, 40ml
  • A-87.893.500 Filling solution 3,5M for Swansensor pH SI+FL; 200ml
Accessories
  • A-75.100.000 QS-Monitor AMI INSPECTOR pH
  • A-81.420.020 AMI Option; Profibus- / Modbus Interface
  • A-81.420.042 AMI Option; USB Interface
  • A-81.420.050 AMI Option; 3rd signal output
  • A-81.420.060 AMI Option; HART Interface
  • A-83.910.120 Screw fitting 12mm/PG 13,5 plus distance sleeve
  • A-87.110.200 Swansensor pH SI
  • A-87.150.200 Swansensor pH FL
  • A-87.410.200 Swansensor Redox SI
  • A-87.411.200 Swansensor Redox FL
  • A-87.860.100 Swansensor Reference FL
  • A-88.121.120 Sensor cable 0.4 meters sleeves/screw plug
  • A-88.224.220 Communication cable, AMI to PC, 2 m
Spare parts
  • A-88.121.120 Sensor cable 0.4 meters sleeves/screw plug
  • A-89.811.060 Set of fuses for AMI
Downloads
F.A.Q.
  • 2 Relay outputs Two potential-free contacts program-able as limit switches for measuring values, controllers or timer with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bi-linear) or as continuous control out-put (control parameters programmable) as current source. 3rd signal output selectable as current source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Ω
  • Optional Profibus- / Modbus Interface
  • Optional HART Interface
  • Optional USB Interface
  • Optional Third 0/4 – 20  mA Output

All Swan Analyzers are CSA Certified before shipping.

Flow rate: 5 to 10 l/h