wjf-logo
1 877 291 5572    |    Contact Us    |    Search

pH or redox Monitor

AMI pH-Redox QV-Flow AC

pH or redox (ORP) in high purity water, steam and condensate.

pH or redox (ORP) in high purity water, steam and condensate.
  • Description
  • Specification
  • Application
  • Options
  • Downloads
  • F.A.Q.

Monitor for continuous measurement of pH or redox (ORP) in high purity water, steam and condensate.

pH or redox Monitor Features:

Complete system mounted on stainless steel panel:

  • Transmitter AMI pH-Redox in a rugged aluminum enclosure (IP 66).
  • Measuring range: 1 to 13 pH respectively -500 to +1’500mV depending on installed sensor.
  • Various combined or separated sensors with reference electrodes available.
  • Flow cell QV-Flow IS1000 made of stainless steel with quick release vessel for easy calibration, needle valve, digital sample flow meter and temperature sensor.
  • Factory tested, ready for installation and operation.

Special features for high purity water with Nernst plus solution temperature compensation.

pH Redox Monitor Analyzer

Specifications:

Complete system mounted on stainless steel mounting panel.

Transmitter in aluminum housing (IP 66) with 2 signal outputs for measuring value or for continuous control, 2 relays as limit switch or controller or timer, 1 alarm relay as summary alarm contact, 1 input for potential-free contact.

Flow cell QV-Flow pHT1000 made of stainless steel SS316L with built-in temperature sensor, flow adjustment valve and digital sample flow meter for two PG13.5 sensors.

  • Measuring range:
    • with Swansensor ST: 1.00 to 13.00 pH respectively -400 to +1’200 mV
    • with Swansensor SI/FL: 1.00 to 12.00 pH respectively -500 to +1’500 m
  • Process connections:
    • Inlet: Swagelok ¼” tube adapter
    • Outlet: G ½” adapter for flexible tube Ø 20 x 15 mm, pressure-free
  • Power Supply
    • 100-240 VAC (±10%)
    • 10-36 VDC
  • Simultaneous measurement of pH or redox, sample temperature and sample flow.
  • Big backlit LC display for the reading of measuring value, sample temperature,
    sample flow and operating status.
  • Easy user menus with simple programming of all parameters by keypad.
  • Two current outputs (0/4 – 20 mA) for measured signals (3rd output optional).

Detailed Specification can be found on Page 2 of the AMI pH-redox monitor Data Sheet.

  • Feed Water.
  • Steam.
  • Condensate.
  • Pure and Ultrapure Water Applications.
  • Power Plants.
Consumables
  • A-85.113.300 Calibration solution pH 7 40ml
  • A-85.114.300 Calibration solution pH 9 40ml
  • A-85.119.010 pH-Calibration set (1x pH 7, 1x pH 9, each 40 ml)
  • A-85.121.300 Redox buffer 475mV, 40ml
  • A-87.893.500 Filling solution 3,5M for Swansensor pH SI+FL; 200ml
Accessories
  • A-75.100.000 QS-Monitor AMI INSPECTOR pH
  • A-81.420.020 AMI Option; Profibus- / Modbus Interface
  • A-81.420.042 AMI Option; USB Interface
  • A-81.420.050 AMI Option; 3rd signal output
  • A-81.420.060 AMI Option; HART Interface
  • A-83.910.120 Screw fitting 12mm/PG 13,5 plus distance sleeve
  • A-87.110.200 Swansensor pH SI
  • A-87.150.200 Swansensor pH FL
  • A-87.410.200 Swansensor Redox SI
  • A-87.411.200 Swansensor Redox FL
  • A-87.860.100 Swansensor Reference FL
  • A-88.121.120 Sensor cable 0.4 meters sleeves/screw plug
  • A-88.224.220 Communication cable, AMI to PC, 2 m
Spare parts
  • A-88.121.120 Sensor cable 0.4 meters sleeves/screw plug
  • A-89.811.060 Set of fuses for AMI
  • 2 Relay outputs Two potential-free contacts program-able as limit switches for measuring values, controllers or timer with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bi-linear) or as continuous control out-put (control parameters programmable) as current source. 3rd signal output selectable as current source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Ω
  • Optional Profibus- / Modbus Interface
  • Optional HART Interface
  • Optional USB Interface
  • Optional Third 0/4 – 20  mA Output

All Swan Analyzers are CSA Cirtified at our premises before shipping.

Flow rate: 5 to 10 l/h

Monitor for continuous measurement of pH or redox (ORP) in high purity water, steam and condensate.

pH or redox Monitor Features:

Complete system mounted on stainless steel panel:

  • Transmitter AMI pH-Redox in a rugged aluminum enclosure (IP 66).
  • Measuring range: 1 to 13 pH respectively -500 to +1’500mV depending on installed sensor.
  • Various combined or separated sensors with reference electrodes available.
  • Flow cell QV-Flow IS1000 made of stainless steel with quick release vessel for easy calibration, needle valve, digital sample flow meter and temperature sensor.
  • Factory tested, ready for installation and operation.

Special features for high purity water with Nernst plus solution temperature compensation.

pH Redox Monitor Analyzer

Specifications:

Complete system mounted on stainless steel mounting panel.

Transmitter in aluminum housing (IP 66) with 2 signal outputs for measuring value or for continuous control, 2 relays as limit switch or controller or timer, 1 alarm relay as summary alarm contact, 1 input for potential-free contact.

Flow cell QV-Flow pHT1000 made of stainless steel SS316L with built-in temperature sensor, flow adjustment valve and digital sample flow meter for two PG13.5 sensors.

  • Measuring range:
    • with Swansensor ST: 1.00 to 13.00 pH respectively -400 to +1’200 mV
    • with Swansensor SI/FL: 1.00 to 12.00 pH respectively -500 to +1’500 m
  • Process connections:
    • Inlet: Swagelok ¼” tube adapter
    • Outlet: G ½” adapter for flexible tube Ø 20 x 15 mm, pressure-free
  • Power Supply
    • 100-240 VAC (±10%)
    • 10-36 VDC
  • Simultaneous measurement of pH or redox, sample temperature and sample flow.
  • Big backlit LC display for the reading of measuring value, sample temperature,
    sample flow and operating status.
  • Easy user menus with simple programming of all parameters by keypad.
  • Two current outputs (0/4 – 20 mA) for measured signals (3rd output optional).

Detailed Specification can be found on Page 2 of the AMI pH-redox monitor Data Sheet.

  • Feed Water.
  • Steam.
  • Condensate.
  • Pure and Ultrapure Water Applications.
  • Power Plants.
Consumables
  • A-85.113.300 Calibration solution pH 7 40ml
  • A-85.114.300 Calibration solution pH 9 40ml
  • A-85.119.010 pH-Calibration set (1x pH 7, 1x pH 9, each 40 ml)
  • A-85.121.300 Redox buffer 475mV, 40ml
  • A-87.893.500 Filling solution 3,5M for Swansensor pH SI+FL; 200ml
Accessories
  • A-75.100.000 QS-Monitor AMI INSPECTOR pH
  • A-81.420.020 AMI Option; Profibus- / Modbus Interface
  • A-81.420.042 AMI Option; USB Interface
  • A-81.420.050 AMI Option; 3rd signal output
  • A-81.420.060 AMI Option; HART Interface
  • A-83.910.120 Screw fitting 12mm/PG 13,5 plus distance sleeve
  • A-87.110.200 Swansensor pH SI
  • A-87.150.200 Swansensor pH FL
  • A-87.410.200 Swansensor Redox SI
  • A-87.411.200 Swansensor Redox FL
  • A-87.860.100 Swansensor Reference FL
  • A-88.121.120 Sensor cable 0.4 meters sleeves/screw plug
  • A-88.224.220 Communication cable, AMI to PC, 2 m
Spare parts
  • A-88.121.120 Sensor cable 0.4 meters sleeves/screw plug
  • A-89.811.060 Set of fuses for AMI
  • 2 Relay outputs Two potential-free contacts program-able as limit switches for measuring values, controllers or timer with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bi-linear) or as continuous control out-put (control parameters programmable) as current source. 3rd signal output selectable as current source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Ω
  • Optional Profibus- / Modbus Interface
  • Optional HART Interface
  • Optional USB Interface
  • Optional Third 0/4 – 20  mA Output

All Swan Analyzers are CSA Cirtified at our premises before shipping.

Flow rate: 5 to 10 l/h