wjf-logo
1 877 291 5572    |    Contact Us    |    Search

TOC Analyzer for High Purity Water

SWAN AMI LineTOC

TOC Analyzer for the continuous measurement of Total Organic Carbon in pure and ultrapure water.

TOC Analyzer
  • Description
  • Specification
  • Application
  • Options
  • Downloads
  • Videos
  • F.A.Q

SWAN Analytical Instrument’s model AMI LineTOC, TOC Analyzer. Continuously monitors total organic carbon (TOC) in purified water and high purity water.

The reagent-free online monitor utilizes a UV oxidation reactor with two high-precision stainless steel conductivity electrodes which perform the measurement by differential conductivity analysis.

A programmable performance test (function test) is available for use and quick and easy grab samples can be run through the system. A System Suitability Test (SST) according to USP <643> is integrated into the system for use for quality control requirements.

Features of the SWAN TOC Analyzer:

  • Continuous measurement
  • Fast results appearing within two minutes after sampling
  • Quick and easy grab sample measurement
  • Automatic system test according to USP and EP
  • Automatic function test daily, weekly or upon request
  • Reagent-free operation
  • Automatic temperature compensation
  • Grab sample function
  • Factory tested and ready for installation and operation


TOC Analyzer applications for the AMI LineTOC, include water for injection (WFI) and purified water (PW) in the range of 0 to 1000ppb of TOC.

Pharmaceutical (pharma) and semiconductor manufacturing are primary industries using purified water anlysis. Optimized sample flow and stable thermal conditions by way of heat exchanger (1 degree C control) ensure accurate measurement.

A simple verification system ensures optimal operation. Protect your purified/high purity/UPW water system from biofilm, germs, organics, or RO system / ion exchanger breakthrough.

TOC Analyzer

Specifications

TOC Analyzer Measurement
Measuring range:0.1 to 1,000 ppb TOC
Resolution:± 0.1 ppb
Max. Conductivity2µS at 20°C
Reproducibility:
0.1 to 50 ppb
50 to 1,000 ppb
± 1 ppb
± 2%

For full specifications please download the Data Sheet

Pharmaceutical and Biotechnological Applications
Strict regulations and audits ask for reliable and continuous monitoring. The AMI LineTOC, TOC Analyzer, meets all requirements to give you peace of mind. As a complete monitoring system it allows you to measure TOC levels in your purified water network with all the necessary documentation and continuous analyzing for constant surveillance of your process.

Semiconductor Production
Monitoring of organic contamination as an indicator for bacterial growth in ultrapure water systems is essential to keep water quality under control. The AMI LineTOC measures trace concentration levels down to 0.1 ppb TOC, which are mandatory for high precision applications such as the microelectronics industry. React early on TOC level variations to prevent costs based on lost product

Consumables

  • A-83.691.000 UV-Reactor LineTOC
  • A-86.191.884 Tubing kit PeriClip pump AMI LineTOC

TOC Analyzer Accessories

  • A-81.420.020 AMI Option; Profibus- / Modbus Interface
  • A-81.420.042 AMI Option; USB Interface
  • A-81.420.050 AMI Option; 3rd signal output
  • A-81.420.060 AMI Option; HART Interface
  • A-82.300.010 Sample Cooler AMI LineTOC
  • A-82.589.000 Pressure Reducing Regulator
  • A-88.224.220 Communication cable, AMI to PC, 2 m

TOC Analyzer Spare parts

  • A-86.191.050 Tubing kit AMI LineTOC
  • A-89.811.060 Set of fuses for AMI
  • C-82.881.000 Air filter Set, 10pcs.
  • C-82.930.061 Bottle PP 250 milliliter
  • C-82.930.062 Bottle PP 125 milliliter

TOC Analyzer for High Purity Water

Exchange of UV Reactor

  • TOC Analyzer Transmitter temperature monitoring with programmable high/low alarm limits
  • 1 Alarm relay One potential free contact for summary alarm indication for programmable alarm values and instrument faults. Maximum load: 1A / 250 VAC
  • 1 Input One input for potential-free contact. Programmable hold or remote off function.
  • 2 Relay outputs Two potential-free contacts programmable as limit switches for measuring values, controllers or timer for system cleaning with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bilinear) or as continuous control outputs (control parameters programmable) as current source.
  • 3rd signal output selectable as cur-rent source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Control functions Relays or current outputs programmable for 1 or 2 pulse dosing pumps, solenoid valves or for one motor valve. Programmable P, PI, PID or PD control parameters.
  • 1 Communication interface (option) RS485 interface (galvanically separated) with Fieldbus protocol Modbus RTU or Pro-fibus DP / 3rd Signal output / USB int

All Swan Analyzers are CSA Cirtified at our premises before shipping.

SWAN Analytical Instrument’s model AMI LineTOC, TOC Analyzer. Continuously monitors total organic carbon (TOC) in purified water and high purity water.

The reagent-free online monitor utilizes a UV oxidation reactor with two high-precision stainless steel conductivity electrodes which perform the measurement by differential conductivity analysis.

A programmable performance test (function test) is available for use and quick and easy grab samples can be run through the system. A System Suitability Test (SST) according to USP <643> is integrated into the system for use for quality control requirements.

Features of the SWAN TOC Analyzer:

  • Continuous measurement
  • Fast results appearing within two minutes after sampling
  • Quick and easy grab sample measurement
  • Automatic system test according to USP and EP
  • Automatic function test daily, weekly or upon request
  • Reagent-free operation
  • Automatic temperature compensation
  • Grab sample function
  • Factory tested and ready for installation and operation


TOC Analyzer applications for the AMI LineTOC, include water for injection (WFI) and purified water (PW) in the range of 0 to 1000ppb of TOC.

Pharmaceutical (pharma) and semiconductor manufacturing are primary industries using purified water anlysis. Optimized sample flow and stable thermal conditions by way of heat exchanger (1 degree C control) ensure accurate measurement.

A simple verification system ensures optimal operation. Protect your purified/high purity/UPW water system from biofilm, germs, organics, or RO system / ion exchanger breakthrough.

TOC Analyzer

Specifications

TOC Analyzer Measurement
Measuring range:0.1 to 1,000 ppb TOC
Resolution:± 0.1 ppb
Max. Conductivity2µS at 20°C
Reproducibility:
0.1 to 50 ppb
50 to 1,000 ppb
± 1 ppb
± 2%

For full specifications please download the Data Sheet

Pharmaceutical and Biotechnological Applications
Strict regulations and audits ask for reliable and continuous monitoring. The AMI LineTOC, TOC Analyzer, meets all requirements to give you peace of mind. As a complete monitoring system it allows you to measure TOC levels in your purified water network with all the necessary documentation and continuous analyzing for constant surveillance of your process.

Semiconductor Production
Monitoring of organic contamination as an indicator for bacterial growth in ultrapure water systems is essential to keep water quality under control. The AMI LineTOC measures trace concentration levels down to 0.1 ppb TOC, which are mandatory for high precision applications such as the microelectronics industry. React early on TOC level variations to prevent costs based on lost product

Consumables

  • A-83.691.000 UV-Reactor LineTOC
  • A-86.191.884 Tubing kit PeriClip pump AMI LineTOC

TOC Analyzer Accessories

  • A-81.420.020 AMI Option; Profibus- / Modbus Interface
  • A-81.420.042 AMI Option; USB Interface
  • A-81.420.050 AMI Option; 3rd signal output
  • A-81.420.060 AMI Option; HART Interface
  • A-82.300.010 Sample Cooler AMI LineTOC
  • A-82.589.000 Pressure Reducing Regulator
  • A-88.224.220 Communication cable, AMI to PC, 2 m

TOC Analyzer Spare parts

  • A-86.191.050 Tubing kit AMI LineTOC
  • A-89.811.060 Set of fuses for AMI
  • C-82.881.000 Air filter Set, 10pcs.
  • C-82.930.061 Bottle PP 250 milliliter
  • C-82.930.062 Bottle PP 125 milliliter

TOC Analyzer for High Purity Water

Exchange of UV Reactor

  • TOC Analyzer Transmitter temperature monitoring with programmable high/low alarm limits
  • 1 Alarm relay One potential free contact for summary alarm indication for programmable alarm values and instrument faults. Maximum load: 1A / 250 VAC
  • 1 Input One input for potential-free contact. Programmable hold or remote off function.
  • 2 Relay outputs Two potential-free contacts programmable as limit switches for measuring values, controllers or timer for system cleaning with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bilinear) or as continuous control outputs (control parameters programmable) as current source.
  • 3rd signal output selectable as cur-rent source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Control functions Relays or current outputs programmable for 1 or 2 pulse dosing pumps, solenoid valves or for one motor valve. Programmable P, PI, PID or PD control parameters.
  • 1 Communication interface (option) RS485 interface (galvanically separated) with Fieldbus protocol Modbus RTU or Pro-fibus DP / 3rd Signal output / USB int

All Swan Analyzers are CSA Cirtified at our premises before shipping.