wjf-logo
1 877 291 5572    |    Contact Us    |    Search

Online Silica Analyzer

Seres Topaz Silica

The continuous measurement of silica in process water, surface water, wastewater and effluents.

Silica Analyzer
  • Description
  • Specification
  • Application
  • Options
  • Downloads
  • F.A.Q

Online Silica Analyzer

Complete monitoring system for the automatic, continuous measurement of silica in process water, surface water, wastewater and effluents.

For the continuous, colorimetric online determination of Silica.

  • Available in separate measuring ranges:
    • Seres OL Topaz Silica MR: 0 to 20 ppm
    • Seres OL Topaz Silica HR: 0 to 50 ppm
    • Seres OL Topaz Silica HRx2: 0 to 100 ppm
  • Complete system including measurement and control electronics, measuring unit, flow indicator, reaction chamber and reagent dosing system.
  • Robust, high quality analyzer cabinet painted stainless steel, 316L.
  • Automatic, electrical zero measurement prior to each measurement cycle.
  • Automatic cell cleaning.
  • 3 easily accessible peristaltic pump modules (4 for HRx2) for accurate, automatic dosing of chemical reagents.
  • 2 analog and 6 digital outputs for alarms for process values and diagnostic alarms for each sample stream.
  • RS485 Modbus/JBUS RTU interface.
  • Large back-lit touchscreen color LCD display for the reading of all measured values and status information simultaneously.
  • Easy menu-guided operation in English or French.

The Serez OL Topaz series provides you with a high-quality industrial-grade Silica analyzer specific to your analysis requirement.

Seres OL Analyzer Topaz Silica

Molybdate method; colorimetric determination of silica ions.

  • Reaction time 15 min.
  • Reaction time 17 min.
  • Topaz Silica MR 0-20 ppm
    • Limit of Detection < 0.1 ppm
    • Repeatability ± 2 % FS
    • Accuracy ± 2 % FS
  • Topaz Silica HR 0-50 ppm
    • Limit of Detection 0.5 ppm
    • Repeatability ± 2 % FS
    • Accuracy ± 2 % FS
  • Topaz Silica HRx2 0-100 ppm
    • Limit of Detection 1 ppm
    • Repeatability ± 3 % FS
    • Accuracy ± 2 % FS

Complete system including measurement and control electronics, measuring unit, flow indicator, reaction chamber and reagent dosing system.

Signal outputs

  • 2 programmable signal outputs for measured values (freely scalable, linear).
  • Current loop: 4 – 20 mA
  • Communication interfaceRS485 interface (galvanically separated) with Modbus/JBUS RTU protocol.
  • Ethernet interface (TCP/IP) optional.

Relays

  • Alarm Relay s 1 summary alarm for ” analyzer failure”Maximum load:1A / 24 V
  • 2 potential-free contacts for each channel programmable as limit switches for measuring values (high/low thresholds)
  • 1 sample flow alarm for each channel
  • 1 output for indication of the active sample stream for each channel.
  • 1 output for maintenance indication.

For full details please view or download the Silica DATE SHEET

  • Silica in Process Water.
  • Silica in Surface Water.
  • Silica in Wastewater.
  • Silica in Effluents.

Analyzer

  • Seres OL Topaz Silica MR (0-20ppm) SOL–55.311.000
  • Seres OL Topaz Silica HR (0-50 ppm) SOL–55.311.100

Configuration

  • Dilution (HRx2) (Range extension 0-100 ppm for Topaz Silica HR) SOL–82.350.020
  • 2-Channel Setup (MR/HR only, similar range) SOL-83.590.020
  • 4-Channel Setup (MR/HR only, similar range) SOL-83.590.040
  • 6-Channel Setup (MR/HR only, similar range) SOL-83.590.060
  • Ethernet Interface (TCP/IP) SOL-81.410.020

Option

  • 1-Year Spare Part Package “Basis” (Analyzer + 1st channel) SOL-84.110.160
  • 1-Year Spare Part Package “Multi-Channel” (add once if multi-channel configuration was selected) SOL-84.110.150
  • Reagent shelf inf SS316L SOL-89.610.010

Reagent specifications

  • Sulfuric acid 4N RXX158
  • Sodium Molybdate 29% RXX116G290
  • Oxalic Acid 10% RXX165
    Reagent Consumption 1.1 l/month

  • Deionized Water (Dilution – Silica HRx2)
    Consumption max 30l/month
  • 2 programmable signal outputs for measured values (freely scalable, linear). Current loop:4 – 20 mA
  • Communication interface RS485 interface (galvanically separated) withModbus/JBUS RTU protocol.
  • Ethernet interface (TCP/IP) optional.

Relays

  • Alarm Relay s 1 summary alarm for ” analyzer failure”Maximum load:1A / 24 V
  • 2 potential-free contacts for each channel programmable as limit switches for measuring values (high/low thresholds)
  • 1 sample flow alarm for each channel
  • 1 output for indication of the active sample stream for each channel.
  • 1 output for maintenance indication.

All Swan Analyzers are CSA Certified at our premises before shipping.

Online Silica Analyzer

Complete monitoring system for the automatic, continuous measurement of silica in process water, surface water, wastewater and effluents.

For the continuous, colorimetric online determination of Silica.

  • Available in separate measuring ranges:
    • Seres OL Topaz Silica MR: 0 to 20 ppm
    • Seres OL Topaz Silica HR: 0 to 50 ppm
    • Seres OL Topaz Silica HRx2: 0 to 100 ppm
  • Complete system including measurement and control electronics, measuring unit, flow indicator, reaction chamber and reagent dosing system.
  • Robust, high quality analyzer cabinet painted stainless steel, 316L.
  • Automatic, electrical zero measurement prior to each measurement cycle.
  • Automatic cell cleaning.
  • 3 easily accessible peristaltic pump modules (4 for HRx2) for accurate, automatic dosing of chemical reagents.
  • 2 analog and 6 digital outputs for alarms for process values and diagnostic alarms for each sample stream.
  • RS485 Modbus/JBUS RTU interface.
  • Large back-lit touchscreen color LCD display for the reading of all measured values and status information simultaneously.
  • Easy menu-guided operation in English or French.

The Serez OL Topaz series provides you with a high-quality industrial-grade Silica analyzer specific to your analysis requirement.

Seres OL Analyzer Topaz Silica

Molybdate method; colorimetric determination of silica ions.

  • Reaction time 15 min.
  • Reaction time 17 min.
  • Topaz Silica MR 0-20 ppm
    • Limit of Detection < 0.1 ppm
    • Repeatability ± 2 % FS
    • Accuracy ± 2 % FS
  • Topaz Silica HR 0-50 ppm
    • Limit of Detection 0.5 ppm
    • Repeatability ± 2 % FS
    • Accuracy ± 2 % FS
  • Topaz Silica HRx2 0-100 ppm
    • Limit of Detection 1 ppm
    • Repeatability ± 3 % FS
    • Accuracy ± 2 % FS

Complete system including measurement and control electronics, measuring unit, flow indicator, reaction chamber and reagent dosing system.

Signal outputs

  • 2 programmable signal outputs for measured values (freely scalable, linear).
  • Current loop: 4 – 20 mA
  • Communication interfaceRS485 interface (galvanically separated) with Modbus/JBUS RTU protocol.
  • Ethernet interface (TCP/IP) optional.

Relays

  • Alarm Relay s 1 summary alarm for ” analyzer failure”Maximum load:1A / 24 V
  • 2 potential-free contacts for each channel programmable as limit switches for measuring values (high/low thresholds)
  • 1 sample flow alarm for each channel
  • 1 output for indication of the active sample stream for each channel.
  • 1 output for maintenance indication.

For full details please view or download the Silica DATE SHEET

  • Silica in Process Water.
  • Silica in Surface Water.
  • Silica in Wastewater.
  • Silica in Effluents.

Analyzer

  • Seres OL Topaz Silica MR (0-20ppm) SOL–55.311.000
  • Seres OL Topaz Silica HR (0-50 ppm) SOL–55.311.100

Configuration

  • Dilution (HRx2) (Range extension 0-100 ppm for Topaz Silica HR) SOL–82.350.020
  • 2-Channel Setup (MR/HR only, similar range) SOL-83.590.020
  • 4-Channel Setup (MR/HR only, similar range) SOL-83.590.040
  • 6-Channel Setup (MR/HR only, similar range) SOL-83.590.060
  • Ethernet Interface (TCP/IP) SOL-81.410.020

Option

  • 1-Year Spare Part Package “Basis” (Analyzer + 1st channel) SOL-84.110.160
  • 1-Year Spare Part Package “Multi-Channel” (add once if multi-channel configuration was selected) SOL-84.110.150
  • Reagent shelf inf SS316L SOL-89.610.010

Reagent specifications

  • Sulfuric acid 4N RXX158
  • Sodium Molybdate 29% RXX116G290
  • Oxalic Acid 10% RXX165
    Reagent Consumption 1.1 l/month

  • Deionized Water (Dilution – Silica HRx2)
    Consumption max 30l/month
  • 2 programmable signal outputs for measured values (freely scalable, linear). Current loop:4 – 20 mA
  • Communication interface RS485 interface (galvanically separated) withModbus/JBUS RTU protocol.
  • Ethernet interface (TCP/IP) optional.

Relays

  • Alarm Relay s 1 summary alarm for ” analyzer failure”Maximum load:1A / 24 V
  • 2 potential-free contacts for each channel programmable as limit switches for measuring values (high/low thresholds)
  • 1 sample flow alarm for each channel
  • 1 output for indication of the active sample stream for each channel.
  • 1 output for maintenance indication.

All Swan Analyzers are CSA Certified at our premises before shipping.