Seres Topaz Phenol

For the continuous, colorimetric online determination of phenol per AFNOR T90-109

Phenol Online Analyzer

Online Phenol Analyzer

Complete monitoring system for the automatic, continuous measurement of phenol C6H5OH in
process water, wastewater and effluents

Features of the Topaz online phenol analyzer include:

  • For the continuous, colorimetric online determination of phenol per AFNOR T90-109.
  • Available in separate measuring ranges :
    • Analyzer Topaz Phenol LR: 0 to 5 ppm.
    • Analyzer Topaz Phenol HR: 0 to 20 ppm.
  • Complete system including measurement and control
    electronics, measuring unit, flow indicator, reaction
    chamber and reagent dosing system.
  • With sample dilution for Topaz Phenol HR.
  • Robust, high quality analyzer cabinet painted stainless
    steel, 316L.
  • Automatic, electrical zero measurement prior to each
    measurement cycle.
  • Automatic cell cleaning.
  • 4 (LR) or 5 (HR) easily accessible peristaltic pump
    modules for accurate, automatic dosing of chemical
    reagents.
  • 2 analog and 7 digital outputs for alarms for process
    values and diagnostic alarms for each sample stream.
  • RS485 Modbus/JBUS RTU interface.
  • Large back-lit touchscreen color LCD display for the
    reading of all measured values and status information
    simultaneously.
  • Easy menu-guided operation in English or French.

The Serez OL Topaz series provides you with a high-quality industrial-grade analyzer specific to your phenol analysis requirement.

 

Phenol Analyzer

Colorimetric method; determination of phenol after chemical reaction in an alkaline environment. Available in separate measuring ranges:

  • Topaz Phenol LR 0-5 ppm
    • Limit of Detection 29 ppb
    • Repeatability ± 2 % FS or ± 0.03 ppm whichever is greater.
    • Precision ± 3 % FS or ± 0.03 ppm whichever is greater
  • Topaz Phenol HR 0-20 ppm
    • Limit of Detection 0.2 ppm
    • Repeatability ± 2 % FS or ± 0.1 ppm whichever is greater.
    • Precision ± 3% FS or ± 0.1 ppm whichever is greater.

Complete system including Detection wavelength 555 nm. Temperature controlled measuring chamber. Sample dilution for Topaz Phenol HR.

Signal outputs

  • 2 programmable signal outputs for measured values (freely scalable, linear).
  • Current loop: 4 – 20 mA
  • Communication interfaceRS485 interface (galvanically separated) with Modbus/JBUS RTU protocol.
  • Ethernet interface (TCP/IP) optional.

Relays

  • Alarm Relay s 1 summary alarm for ” analyzer failure”Maximum load:1A / 24 V
  • 2 potential-free contacts for each channel programmable as limit switches for measuring values (high/low thresholds)
  • 1 sample flow alarm for each channel
  • 1 output for indication of the active sample stream for each channel.
  • 1 output for maintenance indication.

For full details please view or download the DATE SHEET

  • Phenol in Process Water
  • Phenol in Wastewater
  • Phenol in Effluents

Online Phenol Analyzer

  • Analyzer Topaz Phenol LR (0-5 ppm) SOL–55.341.000
  • Analyzer Topaz Phenol HR (0-20 ppm) SOL–55.341.100

Configuration

  • 2-Channel Setup (LR only, similar range) SOL-83.590.020
  • 4-Channel Setup (LR only, similar range) SOL-83.590.040
  • 6-Channel Setup (LR only, similar range) SOL-83.590.060
  • Ethernet Interface (TCP/IP) SOL-81.410.020

Option

  • 1-Year Spare Part Package “Basis” (Analyzer + 1st channel) SOL-84.110.110
  • 1-Year Spare Part Package “Multi-Channel” (add once if multi-channel config. was selected) SOL-84.110.150
  • Reagent Shelf in SS316L SOL-89.610.010

Reagent specifications

  • pH Buffer Solution (pH10) RXX143
    Reagent Consumption 2.5 l/month.
  • Potassium Hexacyanoferrate RXX161
    Reagent Consumption 3.0 l/month.
  • Amino 4 Antipyrine RXX160
    Reagent Consumption 1.5 l/month.
  • Sulfuric Acid 2N RXX159
    Reagent Consumption 2.0 l/month.
  • Deionized Water (Dilution – for Phenol HR only)
    Reagent Consumption ~4000l/month.
  • 2 programmable signal outputs for measured values (freely scalable, linear). Current loop:4 – 20 mA
  • Communication interfaceRS485 interface (galvanically separated) withModbus/JBUS RTU protocol.
  • Ethernet interface (TCP/IP) optional.

 

Relays

  • Alarm Relay s 1 summary alarm for ” analyzer failure”Maximum load:1A / 24 V
  • 2 potential-free contacts for each channel programmable as limit switches for measuring values (high/low thresholds)
  • 1 sample flow alarm for each channel
  • 1 output for indication of the active sample stream for each channel.
  • 1 output for maintenance indication.

All Swan Analyzers are CSA Certified at our premises before shipping.

Description

Online Phenol Analyzer

Complete monitoring system for the automatic, continuous measurement of phenol C6H5OH in
process water, wastewater and effluents

Features of the Topaz online phenol analyzer include:

  • For the continuous, colorimetric online determination of phenol per AFNOR T90-109.
  • Available in separate measuring ranges :
    • Analyzer Topaz Phenol LR: 0 to 5 ppm.
    • Analyzer Topaz Phenol HR: 0 to 20 ppm.
  • Complete system including measurement and control
    electronics, measuring unit, flow indicator, reaction
    chamber and reagent dosing system.
  • With sample dilution for Topaz Phenol HR.
  • Robust, high quality analyzer cabinet painted stainless
    steel, 316L.
  • Automatic, electrical zero measurement prior to each
    measurement cycle.
  • Automatic cell cleaning.
  • 4 (LR) or 5 (HR) easily accessible peristaltic pump
    modules for accurate, automatic dosing of chemical
    reagents.
  • 2 analog and 7 digital outputs for alarms for process
    values and diagnostic alarms for each sample stream.
  • RS485 Modbus/JBUS RTU interface.
  • Large back-lit touchscreen color LCD display for the
    reading of all measured values and status information
    simultaneously.
  • Easy menu-guided operation in English or French.

The Serez OL Topaz series provides you with a high-quality industrial-grade analyzer specific to your phenol analysis requirement.

 

Phenol Analyzer
Specifications

Colorimetric method; determination of phenol after chemical reaction in an alkaline environment. Available in separate measuring ranges:

  • Topaz Phenol LR 0-5 ppm
    • Limit of Detection 29 ppb
    • Repeatability ± 2 % FS or ± 0.03 ppm whichever is greater.
    • Precision ± 3 % FS or ± 0.03 ppm whichever is greater
  • Topaz Phenol HR 0-20 ppm
    • Limit of Detection 0.2 ppm
    • Repeatability ± 2 % FS or ± 0.1 ppm whichever is greater.
    • Precision ± 3% FS or ± 0.1 ppm whichever is greater.

Complete system including Detection wavelength 555 nm. Temperature controlled measuring chamber. Sample dilution for Topaz Phenol HR.

Signal outputs

  • 2 programmable signal outputs for measured values (freely scalable, linear).
  • Current loop: 4 – 20 mA
  • Communication interfaceRS485 interface (galvanically separated) with Modbus/JBUS RTU protocol.
  • Ethernet interface (TCP/IP) optional.

Relays

  • Alarm Relay s 1 summary alarm for ” analyzer failure”Maximum load:1A / 24 V
  • 2 potential-free contacts for each channel programmable as limit switches for measuring values (high/low thresholds)
  • 1 sample flow alarm for each channel
  • 1 output for indication of the active sample stream for each channel.
  • 1 output for maintenance indication.

For full details please view or download the DATE SHEET

Application
  • Phenol in Process Water
  • Phenol in Wastewater
  • Phenol in Effluents
Options

Online Phenol Analyzer

  • Analyzer Topaz Phenol LR (0-5 ppm) SOL–55.341.000
  • Analyzer Topaz Phenol HR (0-20 ppm) SOL–55.341.100

Configuration

  • 2-Channel Setup (LR only, similar range) SOL-83.590.020
  • 4-Channel Setup (LR only, similar range) SOL-83.590.040
  • 6-Channel Setup (LR only, similar range) SOL-83.590.060
  • Ethernet Interface (TCP/IP) SOL-81.410.020

Option

  • 1-Year Spare Part Package “Basis” (Analyzer + 1st channel) SOL-84.110.110
  • 1-Year Spare Part Package “Multi-Channel” (add once if multi-channel config. was selected) SOL-84.110.150
  • Reagent Shelf in SS316L SOL-89.610.010

Reagent specifications

  • pH Buffer Solution (pH10) RXX143
    Reagent Consumption 2.5 l/month.
  • Potassium Hexacyanoferrate RXX161
    Reagent Consumption 3.0 l/month.
  • Amino 4 Antipyrine RXX160
    Reagent Consumption 1.5 l/month.
  • Sulfuric Acid 2N RXX159
    Reagent Consumption 2.0 l/month.
  • Deionized Water (Dilution – for Phenol HR only)
    Reagent Consumption ~4000l/month.
Downloads
F.A.Q
  • 2 programmable signal outputs for measured values (freely scalable, linear). Current loop:4 – 20 mA
  • Communication interfaceRS485 interface (galvanically separated) withModbus/JBUS RTU protocol.
  • Ethernet interface (TCP/IP) optional.

 

Relays

  • Alarm Relay s 1 summary alarm for ” analyzer failure”Maximum load:1A / 24 V
  • 2 potential-free contacts for each channel programmable as limit switches for measuring values (high/low thresholds)
  • 1 sample flow alarm for each channel
  • 1 output for indication of the active sample stream for each channel.
  • 1 output for maintenance indication.

All Swan Analyzers are CSA Certified at our premises before shipping.