Online Ozone Analyzer - AMI Codes-II O3

Swan AMI Codes-II O3

Low maintenance monitor for the measurement of trace concentrations down to 1 ppb of ozone in water for pharmaceutical purposes.

ozone in water Analyzer
  • Description
  • Specification
  • Application
  • Options
  • Downloads
  • F.A.Q.

Online Ozone Analyzer AMI Codes-II O3 is a proven, low-maintenance monitor for the measurement of trace concentrations down to 1 ppb of dissolved ozone in water for pharmaceutical purposes.

Using the robust colorimetric standard measurement method (DPD) according to DIN 38404-3, it is ideally suited to reliably prove the continuous protection of water storage systems against microbial growth as well as the absence of dissolved ozone before the water is used in a pharmaceutical production process.

Online Ozone Analyzer Features:

  • Specific features for the pharmaceutical industry include Audit Trail, Performance verification and a Validation Package
  • Complete system including measurement and control electronics, photometer, flow indicator, reaction chamber, reagent dosing system and reagent containers.
  • All usual dosing devices for disinfectants control can be connected either through relays or analog output signals. Two independent controllers can
    operate simultaneously.
  • Dosing of disinfectant can be interrupted automatically with an external signal.
  • Alarm display and activation of alarm relay when user defined, critical limits for a measurement value are reached.
  • Continuous, automatic monitoring of main instrument functions (dirty photometer, sample flow, reagents).
  • Large back-lit LCD display showing all measured values and status information simultaneously.
  • Factory tested, ready for installation and operation.
  • Measurement range 0-500 ppb suitable for all ozone-sanitized water storage systems.
  • No sensitivity loss: reliable results even during longer-term absence of ozone.
  • Assured long-term stability through automatic zero point detection as part of every measurement.
  • Factory calibrated; simple verification of instrument performance with a filter set.
  • Continuous monitoring of sample flow assures integrity of measured data.

 

Your benefits

  • Straight forward instrument set-up and qualification allows rapid plant integration.
  • Save time due to easy maintenance and no running-in time after maintenance.
  • Confidently protect your production facilities from contamination with ozone containing water.
  • Avoid production interruptions through maximum instrument availability.

 

AMI CodesII 03

Specifications:

Dissolved Ozone Measurement
Measuring range0 to 500 ppb
Accuracy±1 ppb or 5% (whichever is greater)
Limit of detection1 ppb
Cycle time5 … 10 min. (default 6′)
Transmitter Specifications
Power Supply100-240 VAC (±10%), 50/60Hz or 10-36 VDC
Power consumptionmax. 30 VA
Sample conditions
Water consumptionmin. 10 l/h
Water inlet pressure0.15 … 2 bar
Sample temperature5 … 50 °C
Panel
Dimension400 x 850 x 200 mm
Materialstainless steel
Weight14.0 kg

Detailed Specification can be found on Page 2 of this Data Sheet.

  • Water for pharmaceutical purposes
  • Industrial high purity water applications.
  • Ozone Sanitization Systems.
  • Purified water (PW).
  • Highly purified water (HPW).
  • Water for injection (WFI).
Consumables
  • A-85.410.210 Reagent set Oxycon On-line Ozone, 3 sets.
  • A-86.191.151 Tube 2.29mm in frame for PeriClip pump.
Accessories
  • A-70.065.030 Chematest 30.
  • A-70.065.035 Chematest 35.
  • A-81.420.020 AMI Option; Profibus- / Modbus Interface.
  • A-81.420.042 AMI Option; USB Interface.
  • A-81.420.060 AMI Option; HART Interface.
  • A-85.151.300 Verification-kit AMI Codes-II O3.
  • A-96.250.880 Operator’s Manual AMI Codes-II Ozone, German.
  • A-96.250.881 Operator’s Manual AMI Codes-II Ozone, English.
  • A-96.250.882 Operator’s Manual AMI Codes-II Ozone, French.
  • A-96.250.883 Operator’s Manual AMI Codes-II Ozone, Spanish.
  • A-96.260.121 Validation Package AMI Codes-II O3 with IQ/OQ/PQ and SOP, English.
Spare parts
  • A-82.931.060 Reagent container 2.5l with cover.
  • A-83.590.030 Cleaning set for Trides flow cell.
  • A-83.590.036 Spare part set for Codes-II flow cell and fotometer.
  • A-86.170.040 Tubing kit for AMI photometers.
  • A-86.180.020 LD-PE tubing 8/6mm x 3m.
  • A-86.191.871 Tubing kit to suction lance; V2.
  • A-86.191.890 Tubing kit reagent AMI Codes-II and AMI Phosphate-II.
  • A-89.811.060 Set of fuses for AMI.
  • 2 Relay outputs Two potential-free contacts program-able as limit switches for measuring values, controllers or timer with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bi-linear) or as continuous control out-put (control parameters programmable) as current source. 3rd signal output selectable as current source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Ω
  • Optional Profibus- / Modbus Interface
  • Optional HART Interface
  • Optional USB Interface
  • Optional Third 0/4 – 20  mA Output

All Swan Analyzers are CSA Cirtified at our premises before shipping.

Online Ozone Analyzer AMI Codes-II O3 is a proven, low-maintenance monitor for the measurement of trace concentrations down to 1 ppb of dissolved ozone in water for pharmaceutical purposes.

Using the robust colorimetric standard measurement method (DPD) according to DIN 38404-3, it is ideally suited to reliably prove the continuous protection of water storage systems against microbial growth as well as the absence of dissolved ozone before the water is used in a pharmaceutical production process.

Online Ozone Analyzer Features:

  • Specific features for the pharmaceutical industry include Audit Trail, Performance verification and a Validation Package
  • Complete system including measurement and control electronics, photometer, flow indicator, reaction chamber, reagent dosing system and reagent containers.
  • All usual dosing devices for disinfectants control can be connected either through relays or analog output signals. Two independent controllers can
    operate simultaneously.
  • Dosing of disinfectant can be interrupted automatically with an external signal.
  • Alarm display and activation of alarm relay when user defined, critical limits for a measurement value are reached.
  • Continuous, automatic monitoring of main instrument functions (dirty photometer, sample flow, reagents).
  • Large back-lit LCD display showing all measured values and status information simultaneously.
  • Factory tested, ready for installation and operation.
  • Measurement range 0-500 ppb suitable for all ozone-sanitized water storage systems.
  • No sensitivity loss: reliable results even during longer-term absence of ozone.
  • Assured long-term stability through automatic zero point detection as part of every measurement.
  • Factory calibrated; simple verification of instrument performance with a filter set.
  • Continuous monitoring of sample flow assures integrity of measured data.

 

Your benefits

  • Straight forward instrument set-up and qualification allows rapid plant integration.
  • Save time due to easy maintenance and no running-in time after maintenance.
  • Confidently protect your production facilities from contamination with ozone containing water.
  • Avoid production interruptions through maximum instrument availability.

 

AMI CodesII 03

Specifications:

Dissolved Ozone Measurement
Measuring range0 to 500 ppb
Accuracy±1 ppb or 5% (whichever is greater)
Limit of detection1 ppb
Cycle time5 … 10 min. (default 6′)
Transmitter Specifications
Power Supply100-240 VAC (±10%), 50/60Hz or 10-36 VDC
Power consumptionmax. 30 VA
Sample conditions
Water consumptionmin. 10 l/h
Water inlet pressure0.15 … 2 bar
Sample temperature5 … 50 °C
Panel
Dimension400 x 850 x 200 mm
Materialstainless steel
Weight14.0 kg

Detailed Specification can be found on Page 2 of this Data Sheet.

  • Water for pharmaceutical purposes
  • Industrial high purity water applications.
  • Ozone Sanitization Systems.
  • Purified water (PW).
  • Highly purified water (HPW).
  • Water for injection (WFI).
Consumables
  • A-85.410.210 Reagent set Oxycon On-line Ozone, 3 sets.
  • A-86.191.151 Tube 2.29mm in frame for PeriClip pump.
Accessories
  • A-70.065.030 Chematest 30.
  • A-70.065.035 Chematest 35.
  • A-81.420.020 AMI Option; Profibus- / Modbus Interface.
  • A-81.420.042 AMI Option; USB Interface.
  • A-81.420.060 AMI Option; HART Interface.
  • A-85.151.300 Verification-kit AMI Codes-II O3.
  • A-96.250.880 Operator’s Manual AMI Codes-II Ozone, German.
  • A-96.250.881 Operator’s Manual AMI Codes-II Ozone, English.
  • A-96.250.882 Operator’s Manual AMI Codes-II Ozone, French.
  • A-96.250.883 Operator’s Manual AMI Codes-II Ozone, Spanish.
  • A-96.260.121 Validation Package AMI Codes-II O3 with IQ/OQ/PQ and SOP, English.
Spare parts
  • A-82.931.060 Reagent container 2.5l with cover.
  • A-83.590.030 Cleaning set for Trides flow cell.
  • A-83.590.036 Spare part set for Codes-II flow cell and fotometer.
  • A-86.170.040 Tubing kit for AMI photometers.
  • A-86.180.020 LD-PE tubing 8/6mm x 3m.
  • A-86.191.871 Tubing kit to suction lance; V2.
  • A-86.191.890 Tubing kit reagent AMI Codes-II and AMI Phosphate-II.
  • A-89.811.060 Set of fuses for AMI.
  • 2 Relay outputs Two potential-free contacts program-able as limit switches for measuring values, controllers or timer with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bi-linear) or as continuous control out-put (control parameters programmable) as current source. 3rd signal output selectable as current source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Ω
  • Optional Profibus- / Modbus Interface
  • Optional HART Interface
  • Optional USB Interface
  • Optional Third 0/4 – 20  mA Output

All Swan Analyzers are CSA Cirtified at our premises before shipping.