wjf-logo
1 877 291 5572    |    Contact Us    |    Search

Trace Levels of Dissolved Oxygen

AMI Oxytrace

High precision monitor with three electrode Oxytrace G sensor for the continuous measurement of trace levels of dissolved oxygen in high purity water.

levels of dissolved oxygen in high purity water.

High precision monitor with three electrode Oxytrace G sensor for the continuous measurement of trace levels of dissolved oxygen in high purity water.

  • Range: 0-20 ppm or 0-200 % saturation (at 25°C).
  • Automatic air pressure and temperature compensation.
  • Short rinse-down time due to integrated guard.
  • Factory tested, ready for use.


Continuous amperometric measurement of  trace levels of dissolved Oxygen in high purity water.

  • Integrated air pressure and temperature compensation for simple calibration using ambient air.
  • Long-term stable measuring system with robust electrode for minimized operating cost.
  • Easy to handle membrane and electrolyte exchange, sensor cap for up to 24 months of operation.

Swansensor Oxytrace G with three electrode set-up (cathode [gold], anode [silver] and guard [silver]) with integrated NT5k temperature sensor.

Complete system mounted on stainless steel mounting panel.

Transmitter in aluminum housing (IP 66) with 2 signal outputs for measuring value or for continuous control, 2 relays as limit switch or controller or timer, 1 alarm relay as summary alarm contact, 1 input for potential-free contact.

Flow cell QV-Flow PMMA OTG made of acrylic glass with needle valve and digital sample flow meter on mounting angle made of stainless steel.

Trace Levels of Dissolved Oxygen
Monitor AMI Oxytrace
Specifications:
Monitor AMI Oxytrace – Trace Levels of Dissolved Oxygen
Measuring range Measuring range with Swansensor OXYTRACE G (at 25 °C): – 0 – 20.0 ppm O2 or – 0 – 200% saturation
Transmitter Specifications
Power Supply
  • AC Version: 100-240 VAC (±10%), 50/60Hz
  • DC Verson: 10-36 VDC
Power consumption max. 35 VA
Sample conditions
Water consumption 8 to 25 l/h
Water inlet pressure 0.2 to 1 bar
Sample temperature up to 45 °C
Panel
Dimension 280 x 850 x 150 mm
Material stainless steel
Weight 8 kg
Detailed Specification can be found on Page 2 of this Data Sheet.
  • Power and Steam Applications
  • Semiconductor Industry
Consumables
  • A-87.290.050 Sensor Cap Oxytrace G
  • A-87.290.060 DO Filling Solution; 1ALK
Accessories
  • A-75.200.000 QS-Monitor AMI INSPECTOR Oxygen
  • A-81.420.020 AMI Option; Profibus- / Modbus Interface
  • A-81.420.042 AMI Option; USB Interface
  • A-81.420.050 AMI Option; 3rd signal output
  • A-81.420.060 AMI Option; HART Interface
  • A-88.224.220 Communication cable, AMI to PC, 2 m
Spare parts
  • A-83.910.030 Mounting set for sensors 32 mm, without pressure
  • A-89.811.060 Set of fuses for AMI
pdf

AMI Oxytrace Data Sheet: Trace Levels of Dissolved Oxygen .pdf 

  • 2 Relay outputs Two potential-free contacts program-able as limit switches for measuring values, controllers or timer with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bi-linear) or as continuous control out-put (control parameters programmable) as current source. 3rd signal output selectable as current source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Ω
  • Optional Profibus- / Modbus Interface
  • Optional HART Interface
  • Optional USB Interface
  • Optional Third 0/4 – 20  mA Output

All Swan Analyzers are CSA Certified before shipping.

Description

High precision monitor with three electrode Oxytrace G sensor for the continuous measurement of trace levels of dissolved oxygen in high purity water.

  • Range: 0-20 ppm or 0-200 % saturation (at 25°C).
  • Automatic air pressure and temperature compensation.
  • Short rinse-down time due to integrated guard.
  • Factory tested, ready for use.


Continuous amperometric measurement of  trace levels of dissolved Oxygen in high purity water.

  • Integrated air pressure and temperature compensation for simple calibration using ambient air.
  • Long-term stable measuring system with robust electrode for minimized operating cost.
  • Easy to handle membrane and electrolyte exchange, sensor cap for up to 24 months of operation.

Swansensor Oxytrace G with three electrode set-up (cathode [gold], anode [silver] and guard [silver]) with integrated NT5k temperature sensor.

Complete system mounted on stainless steel mounting panel.

Transmitter in aluminum housing (IP 66) with 2 signal outputs for measuring value or for continuous control, 2 relays as limit switch or controller or timer, 1 alarm relay as summary alarm contact, 1 input for potential-free contact.

Flow cell QV-Flow PMMA OTG made of acrylic glass with needle valve and digital sample flow meter on mounting angle made of stainless steel.

Trace Levels of Dissolved Oxygen
Monitor AMI Oxytrace
Specifications
Specifications:
Monitor AMI Oxytrace – Trace Levels of Dissolved Oxygen
Measuring range Measuring range with Swansensor OXYTRACE G (at 25 °C): – 0 – 20.0 ppm O2 or – 0 – 200% saturation
Transmitter Specifications
Power Supply
  • AC Version: 100-240 VAC (±10%), 50/60Hz
  • DC Verson: 10-36 VDC
Power consumption max. 35 VA
Sample conditions
Water consumption 8 to 25 l/h
Water inlet pressure 0.2 to 1 bar
Sample temperature up to 45 °C
Panel
Dimension 280 x 850 x 150 mm
Material stainless steel
Weight 8 kg
Detailed Specification can be found on Page 2 of this Data Sheet.
Application
  • Power and Steam Applications
  • Semiconductor Industry
Options
Consumables
  • A-87.290.050 Sensor Cap Oxytrace G
  • A-87.290.060 DO Filling Solution; 1ALK
Accessories
  • A-75.200.000 QS-Monitor AMI INSPECTOR Oxygen
  • A-81.420.020 AMI Option; Profibus- / Modbus Interface
  • A-81.420.042 AMI Option; USB Interface
  • A-81.420.050 AMI Option; 3rd signal output
  • A-81.420.060 AMI Option; HART Interface
  • A-88.224.220 Communication cable, AMI to PC, 2 m
Spare parts
  • A-83.910.030 Mounting set for sensors 32 mm, without pressure
  • A-89.811.060 Set of fuses for AMI
Downloads
pdf

AMI Oxytrace Data Sheet: Trace Levels of Dissolved Oxygen .pdf 

F.A.Q.
  • 2 Relay outputs Two potential-free contacts program-able as limit switches for measuring values, controllers or timer with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bi-linear) or as continuous control out-put (control parameters programmable) as current source. 3rd signal output selectable as current source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Ω
  • Optional Profibus- / Modbus Interface
  • Optional HART Interface
  • Optional USB Interface
  • Optional Third 0/4 – 20  mA Output

All Swan Analyzers are CSA Certified before shipping.