wjf-logo
1 877 291 5572    |    Contact Us    |    Search

Measurement of pH and redox (ORP)

Monitor pH:mV

pH and Redox (ORP) potential in potable water and effluents. Dual channel monitor for continuous measurement.

Monitor pH:mV

Online Monitor for Continuous Measurement of pH and redox (ORP) in Potable Water and Effluents

This advanced online monitor is designed for the continuous and accurate measurement of pH and ORP levels in potable water and effluent systems.

  • Dual Channel Functionality: The system features a dual-channel transmitter capable of simultaneously supporting two combined pH or ORP sensors, allowing for efficient monitoring of multiple parameters.

  • Comprehensive Measurement: It provides simultaneous measurement of pH, ORP, sample temperature, and sample flow, offering a complete overview of water quality in real-time.

  • Versatile Sensors: The system includes combined sensors that are suitable for various sample conditions, ensuring reliable performance across different environments.

  • Optional Features: For enhanced functionality, the monitor can be equipped with an optional spray nozzle for automatic sensor cleaning, as well as a swansensor deltaT for accurate flow detection.

  • Ready-to-Use System: The monitor is delivered as a complete, panel-mounted system that has been tested, calibrated, and is ready for immediate operation, ensuring a quick and hassle-free installation process.

Transmitter / Controller

  • Rugged aluminium housing IP66
  • Easy full text menu guidance
  • Internal data logger
  • Programmable PID controllers
  • 2 free programmable signal outputs (4 – 20 mA)
  • 2 potential free contacts programmable as PID controllers, limit or alarm switches
  • Internal data logging including alarms, events and calibration data Sensors
  • Swansensor ST/AY: pH 1 to 13 resp. -400 to +1200 mV Swansensor SI/FL: pH 1 to 12 resp. -500 to +1500 mV
pH:mV
Swan AMI pHmV

Specifications

pH Measurement
Measuring range with Swansensor ST/AY pH 1 to 13
Measuring range with Swansensor SI pH 1 to 12
Resolution 0.01 pH
Reference temperature 25° C
Automatic temperature compensation according to Nernst.
ORP (Redox) measurement
Measuring range with Swansensor ST/AY -400 to 1’200 mV
Measuring range with Swansensor SI -500 to 1’500 mV
Resolution 1 mV
Temperature measurement
Measuring range -30 to 130°C
Resolution 0.1° C
Power Supply
Voltage 100-240 VAC (±10%), 50/60Hz or 10-36 VDC
Sample conditions
Flow rate 4 to 15 l/h
Temperature up to 50° C
Inlet pressure up to 1 bar
Outlet pressure pressure free
Dimensions
Panel 280 x 850 x 150 mm
For further information see datasheet.
  • Potable Water and Municipal Wastewater
  • Power and Steam Applications

Consumables

Order/No.Description
A-85.112.300Calibration solution pH 4 40ml
A-85.113.300Calibration solution pH 7 40ml
A-85.113.500Calibration solution pH 7 200ml
A-85.113.700Calibration solution pH 7 1000ml
A-85.114.300Calibration solution pH 9 40ml
A-85.114.500Calibration solution pH 9 200ml
A-85.114.700Calibration solution pH 9 1000ml
A-85.119.010pH-Calibration set (1x pH 7, 1x pH 9, each 40 ml)
A-85.121.300Redox buffer 475mV, 40ml

Accessories

Order/No.Description
A-81.420.020AMI Option; Profibus- / Modbus Interface
A-81.420.042AMI Option; USB Interface
A-81.420.050AMI Option; 3rd signal output
A-81.420.060AMI Option; HART Interface
A-83.491.120Spray nozzle for M-Flow 10-3PG
A-87.120.200Swansensor pH
A-87.130.200Swansensor pH AY
A-87.420.200Swansensor Redox
A-87.430.200Swansensor Redox AY
A-87.933.010Swansensor Flow deltaT
A-88.224.220Communication cable, AMI to PC, 2 m
A-89.812.100Relay box for AMI transmitters

Spare parts

Order/No.Description
A-83.416.330Flow cell Flow cell M-Flow 10-3PG
A-89.811.060Set of fuses for AMI
  • Transmitter temperature monitoring with programmable high/low alarm limits
  • 1 Alarm relay One potential free contact for summary alarm indication for programmable alarm values and instrument faults. Maximum load: 1A / 250 VAC
  • 1 Input One input for potential-free contact. Programmable hold or remote off function.
  • 2 Relay outputs Two potential-free contacts programmable as limit switches for measuring values, controllers or timer for system cleaning with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bilinear) or as continuous control outputs (control parameters programmable) as current source.
  • 3rd signal output selectable as cur-rent source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Control functions Relays or current outputs programmable for 1 or 2 pulse dosing pumps, solenoid valves or for one motor valve. Programmable P, PI, PID or PD control parameters.
  • 1 Communication interface (option) RS485 interface (galvanically separated) with Fieldbus protocol Modbus RTU or Pro-fibus DP / 3rd Signal output / USB int
  • SD card interface Possibility to record measured values and diagnostic data to an SD card. SD card included.

All Swan Analyzers are CSA Certified before shipping.

Description

Online Monitor for Continuous Measurement of pH and redox (ORP) in Potable Water and Effluents

This advanced online monitor is designed for the continuous and accurate measurement of pH and ORP levels in potable water and effluent systems.

  • Dual Channel Functionality: The system features a dual-channel transmitter capable of simultaneously supporting two combined pH or ORP sensors, allowing for efficient monitoring of multiple parameters.

  • Comprehensive Measurement: It provides simultaneous measurement of pH, ORP, sample temperature, and sample flow, offering a complete overview of water quality in real-time.

  • Versatile Sensors: The system includes combined sensors that are suitable for various sample conditions, ensuring reliable performance across different environments.

  • Optional Features: For enhanced functionality, the monitor can be equipped with an optional spray nozzle for automatic sensor cleaning, as well as a swansensor deltaT for accurate flow detection.

  • Ready-to-Use System: The monitor is delivered as a complete, panel-mounted system that has been tested, calibrated, and is ready for immediate operation, ensuring a quick and hassle-free installation process.

Transmitter / Controller

  • Rugged aluminium housing IP66
  • Easy full text menu guidance
  • Internal data logger
  • Programmable PID controllers
  • 2 free programmable signal outputs (4 – 20 mA)
  • 2 potential free contacts programmable as PID controllers, limit or alarm switches
  • Internal data logging including alarms, events and calibration data Sensors
  • Swansensor ST/AY: pH 1 to 13 resp. -400 to +1200 mV Swansensor SI/FL: pH 1 to 12 resp. -500 to +1500 mV
pH:mV
Swan AMI pHmV
Specifications

Specifications

pH Measurement
Measuring range with Swansensor ST/AY pH 1 to 13
Measuring range with Swansensor SI pH 1 to 12
Resolution 0.01 pH
Reference temperature 25° C
Automatic temperature compensation according to Nernst.
ORP (Redox) measurement
Measuring range with Swansensor ST/AY -400 to 1’200 mV
Measuring range with Swansensor SI -500 to 1’500 mV
Resolution 1 mV
Temperature measurement
Measuring range -30 to 130°C
Resolution 0.1° C
Power Supply
Voltage 100-240 VAC (±10%), 50/60Hz or 10-36 VDC
Sample conditions
Flow rate 4 to 15 l/h
Temperature up to 50° C
Inlet pressure up to 1 bar
Outlet pressure pressure free
Dimensions
Panel 280 x 850 x 150 mm
For further information see datasheet.
Application
  • Potable Water and Municipal Wastewater
  • Power and Steam Applications
Options

Consumables

Order/No.Description
A-85.112.300Calibration solution pH 4 40ml
A-85.113.300Calibration solution pH 7 40ml
A-85.113.500Calibration solution pH 7 200ml
A-85.113.700Calibration solution pH 7 1000ml
A-85.114.300Calibration solution pH 9 40ml
A-85.114.500Calibration solution pH 9 200ml
A-85.114.700Calibration solution pH 9 1000ml
A-85.119.010pH-Calibration set (1x pH 7, 1x pH 9, each 40 ml)
A-85.121.300Redox buffer 475mV, 40ml

Accessories

Order/No.Description
A-81.420.020AMI Option; Profibus- / Modbus Interface
A-81.420.042AMI Option; USB Interface
A-81.420.050AMI Option; 3rd signal output
A-81.420.060AMI Option; HART Interface
A-83.491.120Spray nozzle for M-Flow 10-3PG
A-87.120.200Swansensor pH
A-87.130.200Swansensor pH AY
A-87.420.200Swansensor Redox
A-87.430.200Swansensor Redox AY
A-87.933.010Swansensor Flow deltaT
A-88.224.220Communication cable, AMI to PC, 2 m
A-89.812.100Relay box for AMI transmitters

Spare parts

Order/No.Description
A-83.416.330Flow cell Flow cell M-Flow 10-3PG
A-89.811.060Set of fuses for AMI
Downloads
F.A.Q.
  • Transmitter temperature monitoring with programmable high/low alarm limits
  • 1 Alarm relay One potential free contact for summary alarm indication for programmable alarm values and instrument faults. Maximum load: 1A / 250 VAC
  • 1 Input One input for potential-free contact. Programmable hold or remote off function.
  • 2 Relay outputs Two potential-free contacts programmable as limit switches for measuring values, controllers or timer for system cleaning with automatic hold function. Rated load: 1A / 250 VAC
  • 2 Signal outputs (3rd as option)Two programmable signal outputs for measured values (freely scalable, linear or bilinear) or as continuous control outputs (control parameters programmable) as current source.
  • 3rd signal output selectable as cur-rent source or current sink. Current loop: 0/4 – 20 mA Maximum burden: 510 Control functions Relays or current outputs programmable for 1 or 2 pulse dosing pumps, solenoid valves or for one motor valve. Programmable P, PI, PID or PD control parameters.
  • 1 Communication interface (option) RS485 interface (galvanically separated) with Fieldbus protocol Modbus RTU or Pro-fibus DP / 3rd Signal output / USB int
  • SD card interface Possibility to record measured values and diagnostic data to an SD card. SD card included.

All Swan Analyzers are CSA Certified before shipping.