We stock a large selection of Magnetic Flow Meters available for shipping from our location in Calgary, Alberta, Canada.
Below represents a small selection of more popular Flow Meters.
Contact us for advice and consultation regarding flow meter configuration and our expert staff can help you.
The complete full bore magmeter Type Flow Meter 8054/8055, which consists of a magnetic sensor fitting Type S054 or S055 connected to an electronics Type SE56 (blind in compact version or with display in compact or remote version) is designed for applications with liquids with a minimum conductivity of 5 µS/cm.
Combined with a valve as the actuat-ing element, the complete flowmeter Type 8054/8055 can control high-precision dosing operations and flow measurements in potable water treatment and waste water treatment.
The sensor fitting Type S054 or S055 consists of a stainless steel pipe section internally lined with insulating material. Two electrodes mounted opposite to each other on the internal surface of the tube generate an electrical signal. The coils generating the magnetic field are placed outside the pipe. The signal generated by the sensor fitting S054 or S055 must be amplified and processed by an electronics (SE56) which outputs an electrical signal proportional to the fluid flow velocity respectively to the flow rate. Faraday’s induction law is the basis for this magnetic flow meter measurement.
Call 1-877 291 5572 for Flow Meter consultation and configuration questions.
The Mag flow meter 8045 has been designed for pipes with diameters ranging from 1/4” to 16”and liquids having a conductivity > 20 μS/cm.
The transmitter has a large display, a keyboard and provides 4-20 mA, relay and pulse outputs.The version with a stainless steel sensor has been designed for applications with high pressures 230 PSI and high temperatures(up to 230°F)
The E-shaped magnetic system inside the sensor induces a magnetic field into the fluid, which is perpendicular to the direction of flow.Two electrodes are in galvanic contact with the liquid. Based on the Faraday law a voltage can be measured between these electrodes once a liquid (min.conductivity of 20 μS/cm) flows along the pipe. This voltage is proportional to the flow velocity. Using the K factor for the individual pipe diameter the speed of flow is converted into volume per time.
Call 1-877 291 5572 for Flow Meter consultation and configuration questions.
The fittings can be used to connect any INSERTION device for a measurement in the pipe. i.e. sensors, indicators, flow meter transmitters; as in the 8045 Type.
Call 1-877 291 5572 for Flow Meter consultation and configuration questions.