wjf-logo
1 877 291 5572    |    Contact Us    |    Search

Insertion flowmeter with paddle wheel, ELEMENT design - Burkert Type 8026

Designed for measuring the flow rate in solid-free liquids.

water, waste water monitoring, chemical processing, etc.

Insertion flowmeter 8026
  • Description
  • Specification
  • Downloads
The Burkert type 8026 insertion flowmeter is a compact device, specially designed for measuring the flow rate in solid-free liquids, in a variety of applications (water, waste water monitoring, chemical processing, etc.). Type 8026 is available with:
  • 2 configurable outputs: one transistor output (NPN) and one 4…20 mA current output (2-wire)
  • 3 configurable outputs: two transistor outputs (NPN/PNP) and one 4…20 mA current output (2-wire)
  • 4 configurable outputs: two transistor outputs (NPN/PNP) and two 4…20 mA current outputs (3-wire).
Type 8026 converts the measured signal, displays different values in different units (if display/configuration module mounted) and computes the output signals, which are provided via one or two M12 fixed connectors. Thanks to 1 or 2 transistor outputs, the flowmeter can be used to switch a solenoid valve, activate an alarm and, thanks to 1 or 2 current outputs, establish one or two control loops.

Featuring:

  • Up to PN10, size of measurement pipes: DN 20…DN 400
  • Configurable outputs: one or two transistor output(s) and one or two 4…20 mA current output(s)
  • Removable backlit display/configuration module for indication of flow rate and volume with two flow totalizers
  • Automatic calibration using Teach-In, all outputs can be checked without the need for actual flow
INsertion Paddle Wheel Flowmeter

Insertion Flowmeter Specifications

Electrical data
SpecValue
Non wetted parts
HousingStainless steel 1.4404 (316L), PPS
CoverPolycarbonate (PC), transparent (opaque on request)
Display/configurationPC
SealsEPDM, silicone
ScrewsStainless steel 1.4401 (316 (A4))
Fixed connector holderPPS CF30
Fixed connectorNickel-plated brass (Stainless Steel on request)
Grounding terminal and screwStainless steel 1.4301 (304 (A2))
Wetted parts
SealFKM standard (EPDM included, but not mounted)
Axis and bearingsCeramics (Al2O3)
Sensor armature, paddle wheelPVDF
DimensionsDetailed information can be found in chapter “4. Dimensions” on page 6
Measuring principlePaddle wheel
CompatibilityAny pipe from DN 201.)…DN 400 which is fitted with Bürkert S020 Insertion fitting.
For the selection of the nominal diameter of the Insertion fittings, see data sheet Type
S020
Pipe diameterDN 20…DN 400
Measuring range
  • Flow rate: 0.5…75000 l/min (0.13…19813 gpm)
  • Flow velocity: 0.3…10 m/s
Product accessories
Display/configuration moduleGrey dot matrix 128 x 64 with backlighting
insertion Flowmeter Performance data
Measurement deviationTeach-In: ± 1 % of the measured value.) (at Teach-In flow rate value)
Standard K-factor: ± 2.5 % of the measured value.)
Linearity± 0.5 % of full scale
Repeatability± 0.4 % of the measured value
4…20 mA output uncertainty± 1 % of range
Operating voltage
  • 2 or 3 outputs transmitter (2-wire) version: 14…36 V DC, filtered and regulated
  • 4 outputs transmitter (3-wire) version: 12…36 V DC, filtered and regulated
    Connection to main supply: permanent (through external SELV (Safety Extra Low Voltage) and LPS

(Limited Power Source) power supply

Power source (not supplied)Limited power source according to UL/EN 60950-1 standards or limited energy circuit according
to UL/EN 61010-1 §9.4
DC reverse polarity protectionYes
Overvoltage protectionYes
Current consumption

With sensor

  • ≤ 1 A (with transistors load)
  • 2 or 3 outputs transmitter (2-wire) version: ≤ 25 mA (at 14 V DC without transistors load, with
    current loop)
  • 4 outputs transmitter (3-wire) version: ≤ 5 mA (at 12 V DC without transistors load, without
    current loop)
Power consumptionMax. 40 W
Outputs
Transistor

Protected against overvoltage, polarity reversals and short circuit

  • 1 transistor output (transmitter 2-wire):
    • NPN, open collector
    • 1…36 V DC
    • Max. 700 mA
  • 2 transistor outputs (transmitter 2 or 3-wire):
    • Adjustable as sourcing or sinking (respectively both as PNP or NPN ), open collector
    • Max. 700 mA
    • 0.5 A max. per transistor if the 2 transistor outputs are wired
    • NPN-output: 1…36 V DC
    • PNP-output: Power supply
Current

4…20 mA adjustable as sourcing or sinking (in the same mode as transistor):

  • 1 current output (transmitter 2-wire)
    • Max. loop impedance: 1100 Ω at 36 V DC; 610 Ω at 24 V DC; 180 Ω at 14 V DC
  • 2 current outputs (transmitter 3-wire)
    • Max. loop impedance: 1100 Ω at 36 V DC; 610 Ω at 24 V DC; 100 Ω at 12 V DC

Full details can be found in the 8036 Data Sheet

Type 8026 data sheet | Insertion paddle wheel flow sensor with ELEMENT design
The Burkert type 8026 insertion flowmeter is a compact device, specially designed for measuring the flow rate in solid-free liquids, in a variety of applications (water, waste water monitoring, chemical processing, etc.). Type 8026 is available with:
  • 2 configurable outputs: one transistor output (NPN) and one 4…20 mA current output (2-wire)
  • 3 configurable outputs: two transistor outputs (NPN/PNP) and one 4…20 mA current output (2-wire)
  • 4 configurable outputs: two transistor outputs (NPN/PNP) and two 4…20 mA current outputs (3-wire).
Type 8026 converts the measured signal, displays different values in different units (if display/configuration module mounted) and computes the output signals, which are provided via one or two M12 fixed connectors. Thanks to 1 or 2 transistor outputs, the flowmeter can be used to switch a solenoid valve, activate an alarm and, thanks to 1 or 2 current outputs, establish one or two control loops.

Featuring:

  • Up to PN10, size of measurement pipes: DN 20…DN 400
  • Configurable outputs: one or two transistor output(s) and one or two 4…20 mA current output(s)
  • Removable backlit display/configuration module for indication of flow rate and volume with two flow totalizers
  • Automatic calibration using Teach-In, all outputs can be checked without the need for actual flow
INsertion Paddle Wheel Flowmeter

Insertion Flowmeter Specifications

Electrical data
SpecValue
Non wetted parts
HousingStainless steel 1.4404 (316L), PPS
CoverPolycarbonate (PC), transparent (opaque on request)
Display/configurationPC
SealsEPDM, silicone
ScrewsStainless steel 1.4401 (316 (A4))
Fixed connector holderPPS CF30
Fixed connectorNickel-plated brass (Stainless Steel on request)
Grounding terminal and screwStainless steel 1.4301 (304 (A2))
Wetted parts
SealFKM standard (EPDM included, but not mounted)
Axis and bearingsCeramics (Al2O3)
Sensor armature, paddle wheelPVDF
DimensionsDetailed information can be found in chapter “4. Dimensions” on page 6
Measuring principlePaddle wheel
CompatibilityAny pipe from DN 201.)…DN 400 which is fitted with Bürkert S020 Insertion fitting.
For the selection of the nominal diameter of the Insertion fittings, see data sheet Type
S020
Pipe diameterDN 20…DN 400
Measuring range
  • Flow rate: 0.5…75000 l/min (0.13…19813 gpm)
  • Flow velocity: 0.3…10 m/s
Product accessories
Display/configuration moduleGrey dot matrix 128 x 64 with backlighting
insertion Flowmeter Performance data
Measurement deviationTeach-In: ± 1 % of the measured value.) (at Teach-In flow rate value)
Standard K-factor: ± 2.5 % of the measured value.)
Linearity± 0.5 % of full scale
Repeatability± 0.4 % of the measured value
4…20 mA output uncertainty± 1 % of range
Operating voltage
  • 2 or 3 outputs transmitter (2-wire) version: 14…36 V DC, filtered and regulated
  • 4 outputs transmitter (3-wire) version: 12…36 V DC, filtered and regulated
    Connection to main supply: permanent (through external SELV (Safety Extra Low Voltage) and LPS

(Limited Power Source) power supply

Power source (not supplied)Limited power source according to UL/EN 60950-1 standards or limited energy circuit according
to UL/EN 61010-1 §9.4
DC reverse polarity protectionYes
Overvoltage protectionYes
Current consumption

With sensor

  • ≤ 1 A (with transistors load)
  • 2 or 3 outputs transmitter (2-wire) version: ≤ 25 mA (at 14 V DC without transistors load, with
    current loop)
  • 4 outputs transmitter (3-wire) version: ≤ 5 mA (at 12 V DC without transistors load, without
    current loop)
Power consumptionMax. 40 W
Outputs
Transistor

Protected against overvoltage, polarity reversals and short circuit

  • 1 transistor output (transmitter 2-wire):
    • NPN, open collector
    • 1…36 V DC
    • Max. 700 mA
  • 2 transistor outputs (transmitter 2 or 3-wire):
    • Adjustable as sourcing or sinking (respectively both as PNP or NPN ), open collector
    • Max. 700 mA
    • 0.5 A max. per transistor if the 2 transistor outputs are wired
    • NPN-output: 1…36 V DC
    • PNP-output: Power supply
Current

4…20 mA adjustable as sourcing or sinking (in the same mode as transistor):

  • 1 current output (transmitter 2-wire)
    • Max. loop impedance: 1100 Ω at 36 V DC; 610 Ω at 24 V DC; 180 Ω at 14 V DC
  • 2 current outputs (transmitter 3-wire)
    • Max. loop impedance: 1100 Ω at 36 V DC; 610 Ω at 24 V DC; 100 Ω at 12 V DC

Full details can be found in the 8036 Data Sheet

Type 8026 data sheet | Insertion paddle wheel flow sensor with ELEMENT design