The Deltacon DG Degassed Cation Conductivity Analyzer’s continuous information from boiler water, steam and condensate permits for significantly faster turbine startups, saving time and money (it will normally pay for itself within only a few months).

The differentiation between CO2 and impurities is made simple in steam samples with SWAN Analytical degassed cation conductivity analyzer model AMI Deltacon DG.

This innovative on-line instrument is the complete solution for degassed cation conductivity monitoring requirements in cycling power stations.

The AMI Deltacon DG continuously ensures that boiler, condensate and steam samples are contamination-free by removing up to 95% of CO2 in the sample. To do this, it utilizes a precise, automatically controlled reboiler.

In addition to reliable degassed conductivity measurements, the conductivity analyzer also provides the user with specific (total) and cation (acid) conductivity concentrations. The monitor is also able to calculate and display pH or ammonia concentration outputs, and it measures sample flow and temperature as well.

 

Features of the SWAN AMI Deltacon DG Conductivity Analyzer:

  • Stainless steel Larson-Land type reboiler system with automatic boiling point adjustment.
  • Atmospheric pressure compensation for additional boiling point control.
  • System cools re-boiled sample with incoming sample (no separate cooling system required).
  • Three high-precision conductivity sensors with outputs (specific, cationic, degassed).
  • Integrated cation exchanger with exhaustion monitoring.
  • Simultaneous measurement and display of conductivity (x 3), pH, alkalizing reagent.
  • Built-in sample flow control valve, temperature compensation and flow monitoring.
  • Automatic shutoff of reboiler in the case of sample loss.
  • Patented Slot-Lock system for easy sensor maintenance.
  • Electronic drift stabilization.
  • Complete system factory tested, stainless steel panel-mounted, ready for operation.

 

 

The analyzer is highly reliable and proven in determining false positives from rising cation conductivity. Condenser leaks, organic material decomposition (to acetic/formic acid) are easily determined with this advanced yet out of the box degassed conductivity solution.

conductivity analyzer

Degassed Cation Conductivity Analyzer Transmitter AMI Deltacon DG, electronic heater controller, sample reboiler unit and three conductivity sensors UP-Con1000-SL in flow cells Catcon-Plus-SL and B-Flow UP-CON-SL mounted on a stainless steel panel, ready for installation and operation.

Transmitter with two signal outputs for measured values or continuous control, two relays as limit switches or as controllers, alarm relay as summary alarm indication, input for potential free contact.

The flow cell is equipped with a manual flow adjustment valve and a digital sample flow meter.

Cation Conductivity Analyzer Measuring range:

  • 0.055 to 1000 μS/cm,
  • pH 7.5 to 11.5,
  • Ammonia 0.01 to 10 ppm

Sample conditions:

  • Temperature: up to 50 °C
  • Inlet pressure: up to 2 bar
  • Outlet pressure: pressure-free (atmospheric drain)

Sample connections:

  • Inlet: Swagelok ¼” tube adapter
  • Outlet: G ½” adapter for flexible tube 20 x 15 mm

Power Supply

  • 100-240 VAC (±10%)
  • 10-36 VDC


Use of the SWAN Back Pressure Regulator is highly recommended.


For further information see the data sheet

Demin Water Production
Power industry, monitoring demineralized water for boiler feed water and steam generation.

Cation Conductivity Monitoring, Enabling Faster Startup.
The response time of the instrumentation may be reduced by more than half. In this way, the bypass operation time may be markedly reduced, yielding significant benefits.

Degassed Cation Conductivity Analyzer Consumables

  • A-82.841.030 Cation exchanger – bottle; 1 liter, full
  • A-82.841.035 Cation exchanger – resin, 10 liters, without bottle
  • A-82.849.010 Set of spare filters CATCON, 5 pcs.

Accessories

  • A-75.310.000 QS-Monitor AMI INSPECTOR Conductivity
  • A-75.310.002 QS-Monitor AMI INSPECTOR Conductivity, 2 m sensor cable
  • A-81.420.020 AMI Option; Profibus- / Modbus Interface
  • A-81.420.042 AMI Option; USB Interface
  • A-81.420.050 AMI Option; 3rd signal output
  • A-81.420.060 AMI Option; HART Interface
  • A-82.581.001 Back Pressure Regulator; 1 channel with manometer
  • A-82.582.001 Back Pressure Regulator; 2 channel with manometer
  • A-82.583.001 Back Pressure Regulator; 3 channel with manometer
  • A-82.584.001 Back Pressure Regulator; 4 channel with manometer
  • A-88.224.220 Communication cable, AMI to PC, 2 m

Conductivity Analyzer Spare parts

  • A-89.811.060 Set of fuses for AMI
  • C-82.930.040 Bottle PP 1 Litre

Degassed Cation Conductivity Analyzer Webinar Part 1

Degassed Cation Conductivity Analyzer Webinar Part 2

Degassed Cation Conductivity Analyzer Webinar Part 3

  • 1 Alarm relay One potential free contact for summary alarm indication for programmable alarm values and instrument faults. Maximum load: 1A / 250 VAC.
  • 1 Input One input for potential-free contact. Programmable hold or remote off function.
  • 2 Relay outputs Two potential-free contacts programmable as limit switches for measuring values, controllers or timer for system cleaning with automatic hold function. Rated load: 1A / 250 VAC 2 Signal outputs (3rd as option)
  • 2 programmable signal outputs for measured values (freely scaleable, linear or bilinear) or as continuous control outputs (control parameters program-mable). Current loop: 0/4 – 20 mA Maximum burden: 510 Ω
  • Control functions Relays or current outputs programmable for 1 or 2 pulse dosing pumps, solenoid valves or for one motor valve. Programmable P, PI, PID or PD control parameters.
  • 1 Communication interface (option) RS232 interface for logger download to PC with Microsoft HyperTerminal or RS485 interface (galvanically separated) with Fieldbus protocol Modbus or Profibus DP.

All Swan Analyzers are CSA Cirtified at our premises before shipping.

Degassed Cation Conductivity Analyzer

The Deltacon DG Degassed Cation Conductivity Analyzer’s continuous information from boiler water, steam and condensate permits for significantly faster turbine startups, saving time and money (it will normally pay for itself within only a few months).

The differentiation between CO2 and impurities is made simple in steam samples with SWAN Analytical degassed cation conductivity analyzer model AMI Deltacon DG.

This innovative on-line instrument is the complete solution for degassed cation conductivity monitoring requirements in cycling power stations.

The AMI Deltacon DG continuously ensures that boiler, condensate and steam samples are contamination-free by removing up to 95% of CO2 in the sample. To do this, it utilizes a precise, automatically controlled reboiler.

In addition to reliable degassed conductivity measurements, the conductivity analyzer also provides the user with specific (total) and cation (acid) conductivity concentrations. The monitor is also able to calculate and display pH or ammonia concentration outputs, and it measures sample flow and temperature as well.

 

Features of the SWAN AMI Deltacon DG Conductivity Analyzer:

  • Stainless steel Larson-Land type reboiler system with automatic boiling point adjustment.
  • Atmospheric pressure compensation for additional boiling point control.
  • System cools re-boiled sample with incoming sample (no separate cooling system required).
  • Three high-precision conductivity sensors with outputs (specific, cationic, degassed).
  • Integrated cation exchanger with exhaustion monitoring.
  • Simultaneous measurement and display of conductivity (x 3), pH, alkalizing reagent.
  • Built-in sample flow control valve, temperature compensation and flow monitoring.
  • Automatic shutoff of reboiler in the case of sample loss.
  • Patented Slot-Lock system for easy sensor maintenance.
  • Electronic drift stabilization.
  • Complete system factory tested, stainless steel panel-mounted, ready for operation.

 

 

The analyzer is highly reliable and proven in determining false positives from rising cation conductivity. Condenser leaks, organic material decomposition (to acetic/formic acid) are easily determined with this advanced yet out of the box degassed conductivity solution.

conductivity analyzer

Degassed Cation Conductivity Analyzer Transmitter AMI Deltacon DG, electronic heater controller, sample reboiler unit and three conductivity sensors UP-Con1000-SL in flow cells Catcon-Plus-SL and B-Flow UP-CON-SL mounted on a stainless steel panel, ready for installation and operation.

Transmitter with two signal outputs for measured values or continuous control, two relays as limit switches or as controllers, alarm relay as summary alarm indication, input for potential free contact.

The flow cell is equipped with a manual flow adjustment valve and a digital sample flow meter.

Cation Conductivity Analyzer Measuring range:

  • 0.055 to 1000 μS/cm,
  • pH 7.5 to 11.5,
  • Ammonia 0.01 to 10 ppm

Sample conditions:

  • Temperature: up to 50 °C
  • Inlet pressure: up to 2 bar
  • Outlet pressure: pressure-free (atmospheric drain)

Sample connections:

  • Inlet: Swagelok ¼” tube adapter
  • Outlet: G ½” adapter for flexible tube 20 x 15 mm

Power Supply

  • 100-240 VAC (±10%)
  • 10-36 VDC


Use of the SWAN Back Pressure Regulator is highly recommended.


For further information see the data sheet

Demin Water Production
Power industry, monitoring demineralized water for boiler feed water and steam generation.

Cation Conductivity Monitoring, Enabling Faster Startup.
The response time of the instrumentation may be reduced by more than half. In this way, the bypass operation time may be markedly reduced, yielding significant benefits.

Degassed Cation Conductivity Analyzer Consumables

  • A-82.841.030 Cation exchanger – bottle; 1 liter, full
  • A-82.841.035 Cation exchanger – resin, 10 liters, without bottle
  • A-82.849.010 Set of spare filters CATCON, 5 pcs.

Accessories

  • A-75.310.000 QS-Monitor AMI INSPECTOR Conductivity
  • A-75.310.002 QS-Monitor AMI INSPECTOR Conductivity, 2 m sensor cable
  • A-81.420.020 AMI Option; Profibus- / Modbus Interface
  • A-81.420.042 AMI Option; USB Interface
  • A-81.420.050 AMI Option; 3rd signal output
  • A-81.420.060 AMI Option; HART Interface
  • A-82.581.001 Back Pressure Regulator; 1 channel with manometer
  • A-82.582.001 Back Pressure Regulator; 2 channel with manometer
  • A-82.583.001 Back Pressure Regulator; 3 channel with manometer
  • A-82.584.001 Back Pressure Regulator; 4 channel with manometer
  • A-88.224.220 Communication cable, AMI to PC, 2 m

Conductivity Analyzer Spare parts

  • A-89.811.060 Set of fuses for AMI
  • C-82.930.040 Bottle PP 1 Litre

Degassed Cation Conductivity Analyzer Webinar Part 1

Degassed Cation Conductivity Analyzer Webinar Part 2

Degassed Cation Conductivity Analyzer Webinar Part 3

  • 1 Alarm relay One potential free contact for summary alarm indication for programmable alarm values and instrument faults. Maximum load: 1A / 250 VAC.
  • 1 Input One input for potential-free contact. Programmable hold or remote off function.
  • 2 Relay outputs Two potential-free contacts programmable as limit switches for measuring values, controllers or timer for system cleaning with automatic hold function. Rated load: 1A / 250 VAC 2 Signal outputs (3rd as option)
  • 2 programmable signal outputs for measured values (freely scaleable, linear or bilinear) or as continuous control outputs (control parameters program-mable). Current loop: 0/4 – 20 mA Maximum burden: 510 Ω
  • Control functions Relays or current outputs programmable for 1 or 2 pulse dosing pumps, solenoid valves or for one motor valve. Programmable P, PI, PID or PD control parameters.
  • 1 Communication interface (option) RS232 interface for logger download to PC with Microsoft HyperTerminal or RS485 interface (galvanically separated) with Fieldbus protocol Modbus or Profibus DP.

All Swan Analyzers are CSA Cirtified at our premises before shipping.