Home > Valves > Hazardous Location Solenoid Valves > Direct Acting Solenoid Valve 2/2 way Hazardous Area Classification.
The Burkert 6013 solenoid valve is a direct-acting plunger valve.
The stopper and plunger guide tube are welded together to enhance pressure resistance and leak-tightness.
Various seal material combinations are available depending on the application.
A Bürkert-specific flange design (SFB) enables space-saving arrangement of valves on a manifold.
The coils are molded with polyamide or with chemically resistant epoxy.
Pulse coils and ‘Kick and Drop’ electronics are available for overexcitation (plug 2511) for the reduction of electrical power consumption during operation.
Optional manual actuation enables quick commissioning and easy maintenance.
In combination with a plug in accordance with DIN EN 175301-803 Form A, the valves satisfy protection classIP65. Stainless steel valves satisfy NEMA 4X.
Spec | Value |
---|---|
Product Properties & Material | |
Dimensions | Detailed information can be found in chapter “5. Dimensions” on page 5. |
Body | Brass, stainless steel 1.4305 |
Seal | FKM, PTFE/Graphite (EPDM on request) |
Thermal insulation class of solenoid | Polyamide class B Epoxy class H |
Solenoid Valve Performance data | |
Duty cycle/single valve with block assembly on manifold | 100 % continuous rating Intermittent operation 60 % (30 min) or with 5 W coil (on request) |
Circuit function | A and B |
Electrical Data | |
Operating voltage (V+) | Standard version 24 V DC, 24 V/50 Hz, 230 V/50 Hz Analytical version 24 V DC, 230 V/50 Hz (other voltages on request) |
Voltage tolerance | ± 10 % |
Medium Data | |
Standard version | Technical vacuum, neutral gases and liquids (e.g. compressed air, water, hydraulic oil) |
Analytical version | Neutral medium, which does not attack the body and seal materials (see “5.1. Chemical Resistance Chart – Bürkert resistApp” on page 6) |
Viscosity | Max. 21 mm2/s |
Medium temperature | |
With FKM | -10 °C…+ 100 °C (PA coil), -10 °C…+ 120 °C (Epoxy coil) |
With PTFE/Graphite | -40 °C…+ 180 °C (see “5.1. Chemical Resistance Chart – Bürkert resistApp” on page 6) |
With FKM, circuit function B | -10 °C…100 °C (AC),…10 °C…120 °C (DC) |
Process/Port connection & communication | |
Standard version | G ⅛, G ¼, G ⅜, sub-base (SFB) |
Analytical version | G ⅛, G ¼ |
Electrical connection | Tag connector acc. to DIN EN 175301-803 Form A for cable plug Type 2518 (see “10.5. Ordering chart accessories” on page 20) ATEX/IECEx version with 3 m moulded cable |
Approvals and certificates | |
Degree of protection | IP65 with cable plug, ATEX/IECEx junction box version and cable connection version |
Environment and installation | |
Installation | As required, preferably with actuator upright |
Ambient temperature (max.) | + 55 °C |
Installation instructions | No oils, fats or silicone to be used during installation |
Explosion-proof approvals | |
ATEX: EPS 18 ATEX 1232 X II 2G Ex mb IIC T4 Gb II 2D Ex mb IIIC T130 ºC Db II 2G Ex eb mb IIC T4 Gb II 2D Ex mb tb IIIC T130 ºC Db | IECEx: IECEx EPS 18.0110 X Ex mb IIC T4 Gb Ex mb IIIC T130 ºC Db Ex eb mb IIC T4 Gb Ex mb tb IIIC T130 ºC Db |
Approved for Hazardous Locations. CSA, Class 1, Div. 1 and 2, Groups A,B,C and D. Zone 0, Zone 1 and zone 2. |
Full details can be found in the Burkert 6013 Data Sheet
The Burkert 6013 solenoid valve is a direct-acting plunger valve.
The stopper and plunger guide tube are welded together to enhance pressure resistance and leak-tightness.
Various seal material combinations are available depending on the application.
A Bürkert-specific flange design (SFB) enables space-saving arrangement of valves on a manifold.
The coils are molded with polyamide or with chemically resistant epoxy.
Pulse coils and ‘Kick and Drop’ electronics are available for overexcitation (plug 2511) for the reduction of electrical power consumption during operation.
Optional manual actuation enables quick commissioning and easy maintenance.
In combination with a plug in accordance with DIN EN 175301-803 Form A, the valves satisfy protection classIP65. Stainless steel valves satisfy NEMA 4X.
Spec | Value |
---|---|
Product Properties & Material | |
Dimensions | Detailed information can be found in chapter “5. Dimensions” on page 5. |
Body | Brass, stainless steel 1.4305 |
Seal | FKM, PTFE/Graphite (EPDM on request) |
Thermal insulation class of solenoid | Polyamide class B Epoxy class H |
Solenoid Valve Performance data | |
Duty cycle/single valve with block assembly on manifold | 100 % continuous rating Intermittent operation 60 % (30 min) or with 5 W coil (on request) |
Circuit function | A and B |
Electrical Data | |
Operating voltage (V+) | Standard version 24 V DC, 24 V/50 Hz, 230 V/50 Hz Analytical version 24 V DC, 230 V/50 Hz (other voltages on request) |
Voltage tolerance | ± 10 % |
Medium Data | |
Standard version | Technical vacuum, neutral gases and liquids (e.g. compressed air, water, hydraulic oil) |
Analytical version | Neutral medium, which does not attack the body and seal materials (see “5.1. Chemical Resistance Chart – Bürkert resistApp” on page 6) |
Viscosity | Max. 21 mm2/s |
Medium temperature | |
With FKM | -10 °C…+ 100 °C (PA coil), -10 °C…+ 120 °C (Epoxy coil) |
With PTFE/Graphite | -40 °C…+ 180 °C (see “5.1. Chemical Resistance Chart – Bürkert resistApp” on page 6) |
With FKM, circuit function B | -10 °C…100 °C (AC),…10 °C…120 °C (DC) |
Process/Port connection & communication | |
Standard version | G ⅛, G ¼, G ⅜, sub-base (SFB) |
Analytical version | G ⅛, G ¼ |
Electrical connection | Tag connector acc. to DIN EN 175301-803 Form A for cable plug Type 2518 (see “10.5. Ordering chart accessories” on page 20) ATEX/IECEx version with 3 m moulded cable |
Approvals and certificates | |
Degree of protection | IP65 with cable plug, ATEX/IECEx junction box version and cable connection version |
Environment and installation | |
Installation | As required, preferably with actuator upright |
Ambient temperature (max.) | + 55 °C |
Installation instructions | No oils, fats or silicone to be used during installation |
Explosion-proof approvals | |
ATEX: EPS 18 ATEX 1232 X II 2G Ex mb IIC T4 Gb II 2D Ex mb IIIC T130 ºC Db II 2G Ex eb mb IIC T4 Gb II 2D Ex mb tb IIIC T130 ºC Db | IECEx: IECEx EPS 18.0110 X Ex mb IIC T4 Gb Ex mb IIIC T130 ºC Db Ex eb mb IIC T4 Gb Ex mb tb IIIC T130 ºC Db |
Approved for Hazardous Locations. CSA, Class 1, Div. 1 and 2, Groups A,B,C and D. Zone 0, Zone 1 and zone 2. |
Full details can be found in the Burkert 6013 Data Sheet
WJF Instrumentation Ltd.
#5 3610 – 29th Street N.E.
Calgary, Alberta
Canada
T1Y 5Z7
Calgary Head Office
Toll-Free: (877)291-5572
Standard: (403)291-5570
Ontario & Maritimes Sales:
(905)809-6918